Search results for "Glaucoma"
showing 10 items of 317 documents
Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension.
2002
Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open angle glaucoma (POAG) and high IOP, normal tension glaucoma (NTG), and ocular hypertension (OHT). Furthermore, the authors examined whether there were any correlations with blood pressure.80 subjects were divided into four groups (n=20): 20 patients each with POAG, NTG, and OHT and 20 volunteers without any ocular pat…
Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
2013
Purpose To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and methods Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Saf…
Risk factors of ocular hypertension and glaucoma. The Casteldaccia Eye Study.
1994
A case-control study was planned as a part of the Casteldaccia Eye Study in order to investigate about risk factors of ocular hypertension and glaucoma. Cases were 44 subjects with glaucoma or intraocular pressure of 24 mm Hg or more. Controls were 220 subjects with intraocular pressure of 20 mm Hg or less and no signs of glaucoma. A number of environmental, behavioral, systemic and ocular variables were studied. Among the others we investigated the following: sunlight exposure, smoking, alcohol intake, pregnancies, systemic hypertension, diabetes, use of corticosteroids, refractive status, anterior chamber depth, lens nuclear sclerosis, iris color and texture. After univariate analysis the…
Falsely elevated intraocular pressure due to increased central corneal thickness
1999
PURPOSE: To evaluate whether ocular hypertensive subjects have a higher central corneal thickness than other individuals. METHODS: In this prospective study, 48 subjects with ocular hypertension, 63 patients with open-angle glaucoma, 56 nonglaucomatous patients with diabetes mellitus, and 106 control subjects were evaluated. Corneal thickness was measured by ultrasound pachymetry, and intraocular pressure was determined by Goldmann applanation tonometry. RESULTS: Central corneal thickness was significantly higher in the ocular hypertensive subjects, mean +/- S.D., 592+/-39 microm, than in the patients with glaucoma (536+/-34 microm), the nonglaucomatous patients with diabetes mellitus (550+…
Peripapillary Choroidal Thickness and Choroidal Area in Glaucoma, Ocular Hypertension and Healthy Subjects by SD-OCT.
2015
Background: The exact pathogenesis of open angle glaucoma and ocular hypertension remains unclear. Hemodynamic influences are discussed as potential risk factors and the choroid may play an important role in the pathogenesis of open angle glaucoma or ocular hypertension. The current study investigates peripapillary choroidal thickness and choroidal area in patients with open angle glaucoma, subjects with ocular hypertension and healthy subjects using spectral-domain OCT. It furthermore assesses the association between peripapillary choroidal thickness and age, central corneal thickness, refractive error and intraocular pressure. Patients and Methods: Prospectively recorded data of 213 eyes …
Influence of Refraction on Tonometric Readings After Photorefractive Keratectomy and Laser Assisted In Situ Keratomileusis
2000
PURPOSE To determine the decrease of Goldmann tonometry after photorefractive keratectomy (PRK) and laser assisted in situ keratomileusis (LASIK) according to refraction prior to surgery. METHODS Prospective simultaneous comparative case series of 53 myopic eyes (53 patients) that underwent PRK and 50 (50 patients) that underwent LASIK using the Summit Excimed SVS plus (Summit Technology, Inc., Walthan, MA, U.S.A.). PRK and LASIK were subdivided by refractive error into two subgroups of more than or less than -5 diopters (D). Central tonometric readings were taken prior to surgery and 12 months after surgery. RESULTS In LASIK and PRK subgroups of more than -5 D, 85.7% (24) and 69.6% (24), r…
Long-term results of surgical treatment of high myopia with Worst-Fechner intraocular lenses
1995
Abstract This retrospective study evaluated the results in 90 eyes that had a minus-power anterior chamber intraocular lens implanted to correct high myopia. Preoperative myopia ranged from −7.00 to −24.00 D. Postoperative spherical equivalent was −0.50 D; 80.5% of eyes were within 1.00 D of emmetropia. Two years postoperatively, no cataract formation, retinal detachment, glaucoma, or significant endothelial damage had occurred. We conclude that minus-power lenses can rapidly, safely, and predictably correct high myopia in phakic patients.
Long-term Results After Transconjunctival Resuturing of the Scleral Flap in Hypotony Following Trabeculectomy
2013
Purpose To present the 4-year follow-up results in the surgical treatment of hypotony following trabeculectomy with mitomycin C in glaucoma patients with additional flap sutures. Design Retrospective interventional case series. Methods Since 2006, 53 patients with hypotony maculopathy attributable to overfiltration following glaucoma surgery (trabeculectomy with mitomycin C) were included in this institutional study. We were able to follow up intraocular pressure (IOP) and distance-corrected visual acuity in 33 (62%) over 4 years, whereas all were followed over 2 years. To elevate IOP, we placed tangential transconjunctival sutures through the scleral flap and connected them to the adjacent…
Results of an Adaptive Surgical Approach for Managing Late Onset Hypotony After Trabeculectomy With Mitomycin C.
2018
OBJECTIVES The objective of this study is to investigate the results of an adaptive approach of bleb revision surgery for late onset hypotony after trabeculectomy with mitomycin C because of bleb leakage and/or scleral melting. METHODS A total of 29 eyes of 27 patients, aged 63.8±11.7 years with hypotony maculopathy [intraocular pressure (IOP), ≤6 mm Hg] because of late onset bleb leakage and/or scleral melting after trabeculectomy with mitomycin C in which minimally invasive transconjunctival suturing of the scleral flap was impossible were enrolled in this retrospective interventional case series. External bleb leakage was seen in 16 eyes, 11 eyes suffered from scleral melting. Because of…
Structure-function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients.
2012
Purpose Flicker defined form perimetry (FDF) and frequency doubling technology perimetry (FDT) are alleged to detect glaucoma at an earlier stage than standard automated perimetry (SAP). It is the purpose of this study to investigate the structure-function relationship between FDF, FDT, SAP, and confocal scanning laser ophthalmoscopy (cSLO) in patients with glaucoma. Methods Seventy-six patients with glaucoma were included in the study. Patients were tested with SAP, Matrix-FDT, FDF perimetry, and cSLO. Structure-function relationships between global and sectoral cSLO parameters and global and sectoral mean sensitivity (MS) of SAP, Matrix-FDT, and FDF were calculated using Spearman's rank c…