Search results for "HEMODYNAMICS"
showing 10 items of 511 documents
Pixel-to-pixel correlation between images of absolute ATP concentrations and blood flow in tumours
1992
Iodo(14C-)antipyrine autoradiography and imaging bioluminescence have been combined to obtain pixel-to-pixel correlations between absolute values for local blood flow and ATP concentrations at a microscopical level within designated areas in hamster melanomas. Positive pixel-to-pixel correlations were obtained in 4 of 6 tumours. Both flow and ATP values were less in mostly necrotic than in mostly viable tumour regions. The data provide evidence for the energetic state of cancer cells being strongly influenced by the efficiency of tumour microcirculation in several but not in all malignancies investigated. Images Figure 1
Intracoronary application of C1 esterase inhibitor improves cardiac function and reduces myocardial necrosis in an experimental model of ischemia and…
1997
Background Myocardial injury from ischemia can be aggravated by reperfusion of the jeopardized area. The precise underlying mechanisms have not been clearly defined, but proinflammatory events, including complement activation, leukocyte adhesion, and infiltration and release of diverse mediators, probably play important roles. The present study addresses the possibility of reducing reperfusion damage by the application of C1 esterase inhibitor (C1-INH). Methods and Results Cardioprotection by C1-INH 20 IU/kg IC was examined in a pig model with 60 minutes of coronary occlusion, followed by 120 minutes of reperfusion. C1-INH was administered during the first 5 minutes of coronary reperfusion…
Recombinant growth hormone therapy in patients with ischemic cardiomyopathy : effects on hemodynamics, left ventricular function, and cardiopulmonary…
1999
Background —We studied the effects of recombinant growth hormone (rhGH) on exercise capacity and cardiac function in patients with ischemic cardiomyopathy. Methods and Results —Seven patients (aged 55±9 years) with mild to moderate congestive heart failure (ejection fraction 31±4%) who were on standard therapy were included. The patients were studied at baseline, after 3 months of rhGH treatment, and 3 months after rhGH discontinuation. Cardiac function was assessed by exercise capacity, right heart catheterization at rest and after submaximal exercise, MRI, echocardiography, and Holter monitoring. When administered at a dose of 2 IU/d, rhGH doubled the serum concentration of insulin-like …
PiCCO plus: monitorización cardiopulmonar mínimamente invasiva
2008
Insertion of a central venous catheter and an arterial catheter would be indicated in hemodynamically unstable or severely hypoxic patients in critical care units. In this setting, cardiorespiratory monitoring by transpulmonary thermodilution (TPTD) can be considered minimally invasive given that only a single arterial thermodilution catheter and a single central venous catheter are required to be connected to a specific monitor (the PiCCO Plus, Pulsion Medical Systems, Munich, Germany). TDTP simultaneously measures cardiac output, preloading, and cardiac function in hemodynamically unstable patients and predicts the response to volume. The technique can be managed by any health care profes…
Hämodynamik nach sublingualer Applikation von Captopril bei schwerer Herzinsuffizienz*: Eine Pilotstudie
2008
In a preliminary trial, 23 patients in severe left-heart failure and, in some instances, also right-heart failure (NYHA classes III and IV) received a single sublingual dose of 25 mg captopril. Invasive measurement of various haemodynamic parameters indicated (1) an increase in cardiac index and stroke-volume index of 34% and 38%, respectively (P less than 0.001 for each); (2) decrease in pulmonary artery and systemic pressures by an average of 7% and 11.4% (P less than 0.01 and less than 0.001, respectively); (3) no significant change in heart rate and mean right atrial pressure; (4) decrease in systemic and pulmonary artery resistance by 33% and 29% (P less than 0.001 for both); (5) an in…
Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively
2009
Background Fluid management guided by oesophageal Doppler monitor has been reported to improve perioperative outcome. Stroke volume variation (SVV) is considered a reliable clinical predictor of fluid responsiveness. Consequently, the aim of the present trial was to evaluate the accuracy of SVV determined by arterial pulse contour (APCO) analysis, using the FloTrac™/Vigileo™ system, to predict fluid responsiveness as measured by the oesophageal Doppler. Methods Patients undergoing major abdominal surgery received intraoperative fluid management guided by oesophageal Doppler monitoring. Fluid boluses of 250 ml each were administered in case of a decrease in corrected flow time (FTc) to 10%. …
Evaluation of Hemodynamic Parameters for Adaptive Control of the Artificial Heart by Simulation of the Vascular System
1984
Abstract A nonlinear dynamic mathematical model of the cardiovascular system is outlined, which is employable to analyse the hemodynamic system behaviour under normal as well as under pathological conditions. By modifying this model, assuming that cardiac output is constant at a preset level (which is in accordance with most of the total artificial heart systems, since their pumps output is preselected with fixed driving parameters), the hemodynamic behaviour of a circulation system with an artificial heart was simulated. Comparing the simulation results with those obtained from total artificial heart experiments, a good agreement in right atrial and aortic pressure under exercise condition…
Hemodynamic Parameters Change Earlier Than Tissue Oxygen Tension in Hemorrhage
2010
BACKGROUND: Untreated hypovolemia results in impaired outcome. This study tests our hypothesis whether general hemodynamic parameters detect acute blood loss earlier than monitoring parameters of regional tissue beds. MATERIALS AND METHODS: Eight pigs (23-25 kg) were anesthetized and mechanically ventilated. A pulmonary artery catheter and an arterial catheter were inserted. Tissue oxygen tension was measured with Clark-type electrodes in the jejunal and colonic wall, in the liver, and subcutaneously. Jejunal microcirculation was assessed by laser Doppler flowmetry (LDF). Intravascular volume was optimized using difference in pulse pressure (dPP) to keep dPP below 13%. Sixty minutes after p…
Pulmonary haemodynamics in obstructive sleep apnoea.
1995
In patients with obstructive sleep apnoea syndrome (OSAS), pulmonary haemodynamics can show both transient perturbations during sleep and permanent alterations. During sleep, repeated fluctuations in pulmonary artery pressure and pulmonary wedge pressure, coincident with apnoeas, can be observed. Calculation of transmural pressure values is preferable to intravascular pressures in OSAS, due to the marked swings in intrathoracic pressure associated with obstructive apnoeas. Pulmonary artery pressure may progressively increase during sleep, particularly in close sequences of highly desaturating apnoeas. Apnoea-induced hypoxia appears as the most important determinant of this pulmonary artery …
Cardiac output following fetoscopic coagulation of major placental vessels in fetal sheep.
2008
Objectives To measure changes in cardiac output (CO) after partial cord occlusion in fetal sheep in order to investigate pathophysiological fetal adaptation mechanisms in a simulated acute placental insufficiency model under standardized conditions, with the aim of finding relevant methods for monitoring human fetuses during stress situations. Methods We used minimally invasive, percutaneous endoscopic techniques to close umbilical vessels in mid-gestational fetal sheep. Placental blood flow was reduced by preferentially closing first arterial and then the concomitant venous umbilical vessels within a short time interval. The investigations were carried out on 11 pregnant ewes at a median g…