Search results for "HMI"
showing 10 items of 931 documents
Arrhythmias and inhibition of noradrenaline uptake caused by tricyclic antidepressants and chlorpromazine on the isolated perfused rabbit heart
1975
1. Isolated rabbit hearts were perfused with a modified Tyrode solution containing noradrenaline in concentrations increasing stepwise from 5.9 nM to 5.9 μM at 5 min intervals. This dose regime was applied twice before and once 20 min after starting perfusion with one of 9 tricyclic drugs. Ventricular rate and right atrial and ventricular tensions were recorded using the transverse method. 2. Infusions of noradrenaline evoked ventricular arrhythmias in hearts perfused with amitriptyline 4.8 μM, chlorpromazine 5.0 μM, desipramine 5.0 μM, dibenzepine 34.7 μM, doxepin 4.7 μM, imipramine 4.7 μM, noxiptiline 9.1 μM and opipramole 9.2 μM. The incidence of arrhythmias increased with the concentrat…
ICD Implantation in infants and small children: the extracardiac technique.
2007
There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…
ANTI-ARRHYTHMIC EFFECT OF DEHYDROBENZPERIDOL IN DOGS
1971
SUMMARY The anti-arrhythmic activity of dehydrobenzperidol (DBP) was studied during halothane anaesthesia in dogs. Arrhythmias were provoked by single intravenous injections of catecholamines. Two groups of dogs were studied. One received norepinephrine and the odier epinephrine. The dose just sufficient to initiate arrirythmias was defined as the “threshold”. Electrocardiogram, blood pressure and heart rate were monitored. The principal findings were:— 1 The dog heart was “sensitized” to epinephrine and norepinephrine by halothane. 2 DBP did have an anti-arrhydimic action. A dose of 0.150 mg/kg roughly doubled the “threshold”. 3 DBP had significant alpha-adrenergic blocking properties. …
Atrial fibrillation in highly trained endurance athletes — Description of a syndrome
2016
Atrial fibrillation (AF) is the most common heart arrhythmia, the risk of which typically increases with age. This condition is commonly associated with major cardiovascular diseases and structural heart damage, while it is rarely observed in healthy young people. However, increasing evidence indicates that paroxysmal AF can also onset in young or middle-aged and otherwise healthy endurance athletes (e.g., cyclists, runners and cross-country skiers). Here we review the topic of AF associated with strenuous endurance exercise (SEE), for example cycling, running and cross-country skiing, especially at a competitive level, and we propose the definition of a new syndrome based on the accumulati…
Arrhythmic sudden cardiac death in a 3-year-old child with intimal fibroplasia of coronary arteries, aorta, and its branches
2001
Abstract We report an unusual case of “arrhythmic” sudden cardiac death in a 3-year-old child who died of ischemic myocardial lesions as a result of intimal fibroplasia of the coronary arteries. Also affected were the aorta and its major branches, whereas renal and mesenteric arteries, celiac trunk, and systemic veins were normal. Histopathologic examination showed severe concentric thickening of intima because of a proliferation of spindle-shaped cells (mesenchymal cells) set in an abundant extracellular matrix. In some vascular segments the intima was densely fibrotic and hyalinized. No significant inflammation, foam cells, cholesterol clefts, or other evidence of atheroma were present. T…
Permanent Pacemaker Lead Insertion Connected to an External Pacemaker Generator for Temporary Pacing After Transcatheter Aortic Valve Implantation.
2019
Abstract Background Outcomes after transcatheter aortic valve implantation (TAVI) have been demonstrated to be at least equivalent in the short term compared to surgical valve implantation (SAVI). However, Conduction abnormalities are more common after TAVI than SAVI and the need for permanent pacemaker implantation is more common after TAVI with the currently commercially available self-expanding valves than after SAVI. Temporary pacemaker implantation may be associated with inability to ambulate, lead migration or perforation and infection. Depending on the monitoring system, some arrhythmias may not be detected. We examined the feasibility and safety of permanent pacemaker lead implantat…
Pacemaker-Based Cardiac Neuromodulation Therapy in Patients With Hypertension: A Pilot Study.
2021
Background In prior unblinded studies, cardiac neuromodulation therapy (CNT) employing a sequence of variably timed short and longer atrioventricular intervals yielded sustained reductions of systolic blood pressure (SBP) in patients with hypertension. The effects of CNT on SBP were investigated in this double‐blind randomized pilot study. Methods and Results Eligible patients had daytime ambulatory SBP (aSBP) ≥130 mm Hg and office SBP ≥140 mm Hg despite taking ≥1 antihypertensive medication, and an indication for a dual‐chamber pacemaker. Patients underwent Moderato device implantation, which was programmed as a standard pacemaker during a 1‐month run‐in phase. Patients whose daytime aSBP…
Inhibition by Fendiline of the Transient Outward Current in Rat Ventricular Cardiomyocytes
1999
The effects of fendiline on the transient outward current (Ito) were investigated in rat ventricular cardiomyocytes. Extracellularly applied fendiline reduced peak and steady-state current amplitude of Ito; the inactivation of Ito was accelerated by the drug, which reflects onset of block. The described effects were concentration dependent: half-maximal effects were achieved at approximately 3 microM fendiline. Intracellularly applied fendiline (3 microM) did not affect Ito within 5 min. The steady-state current amplitude of Ito was more efficiently suppressed by the drug at 22 +/- 1 degrees C than at 36 +/- 1 degrees C. The recovery of Ito was analyzed by the application of twin depolarizi…
Validation of a novel contact-free heart and respiratory rate monitor.
2021
There is a growing need for remote monitoring of patients due to a lack of resources and infection control. Current systems use sensors that require constant physical contact with the user, which may result in discomfort or lack of adherence. In the present study, we evaluated the accuracy of a new contact-free system to monitor heart and respiratory rate. Study participants were measured simultaneously using two devices: a contact-free optical system that measures nano-vibrations and movements (investigational device, "Gili Pro BioSensor") and a standard reference bed-side monitor, inclusive of an electrocardiogram and capnograph modules (Mindray