Search results for "Heart Block"

showing 9 items of 19 documents

Cardiac pacing in premature infants and neonates: steroid eluting leads and automatic output adaptation

1999

Abstract Background . Appropriate generator and lead selection as well as techniques of implantation are most important aspects of cardiac pacing in the extremely young patient. Here we report the clinical results using a new technique with automatic output adaptation based on evoked response in combination with steroid-eluting epicardial leads in small children. Methods . One neonate and 2 premature infants underwent permanent pacemaker implantation because of congenital high-degree atrioventricular block or postoperative complete heart block, respectively. Steroid-eluting epicardial leads and a multiprogrammable pacemaker with automatic output adaptation were used. Results . Intermuscular…

Heart Defects CongenitalPulmonary and Respiratory MedicinePacemaker ArtificialCardiac pacingInfant Premature DiseasesPostoperative complete heart blockmedicineHumansLead (electronics)Bipolar leadbusiness.industryCardiac Pacing ArtificialInfant NewbornSmall childrenInfantmedicine.diseasePatient populationAnesthesiaFemaleSurgeryPermanent pacemakerCardiology and Cardiovascular MedicinebusinessAtrioventricular blockAlgorithmsInfant PrematureThe Annals of Thoracic Surgery
researchProduct

Episodes of second-degree ventriculo-atrial block during ventricular tachycardia

2017

Male0301 basic medicinemedicine.medical_specialtySettore MED/09 - Medicina Internabusiness.industrysecond degree ventriculo-atrial block ventricular tachycardiaGeneral MedicineVentricular tachycardiamedicine.diseaseDegree (temperature)Electrocardiography03 medical and health sciencesHeart Block030104 developmental biologyInternal medicineBlock (telecommunications)Tachycardia VentricularmedicineCardiologyHumansCardiology and Cardiovascular MedicinebusinessAgedJournal of Cardiovascular Medicine
researchProduct

Complete congenital heart block is associated with increased autoantibody titers against calreticulin.

1996

Complete congenital heart block (CCHB) is associated with anti-Ro/SS-A and anti-La/SS-B antibodies. Calreticulin, a calcium-binding, multi-functional protein of the endoplasmic reticulum with C-terminal KDEL-sequence, is not part of the Ro/SS-A ribonucleoprotein complex. In this study anti-calreticulin autoantibody responses in serum samples from 18 infants with CCHB, their mothers and in a control group of 11 anti-Ro/SS-A or anti-La/SS-B positive infants without heart block and their mothers were analysed. Specific enzyme-linked immunosorbent assays were performed. Nine out of 18 sera with CCHB contained IgG anti-calreticulin antibodies. Four sera of those with IgG antibodies also had IgM …

MaleClinical BiochemistryBlotting WesternEnzyme-Linked Immunosorbent AssayBiochemistryAutoantigensImmunopathologymedicineHumansNeonatal lupus erythematosusAutoantibodiesAutoimmune diseaseLupus erythematosusbiologybusiness.industryCalcium-Binding ProteinsAutoantibodyInfant NewbornGeneral Medicinemedicine.diseaseConnective tissue diseaseHeart BlockImmunoglobulin MRibonucleoproteinsImmunoglobulin GImmunologybiology.proteinFemaleAntibodybusinessCalreticulinCalreticulinEuropean journal of clinical investigation
researchProduct

Massive digoxin intoxication in childhood.

1978

In a 10 year old boy 8 hours after taking about 16 mg beta-acetyl-digoxin a maximum serum digoxin level of 31.8 ng/ml was measured radioimmunologically. This is the highest digitalis level in childhood described to date. The serum potassium level rose to 7.4 mmol/l. Complete atrio-ventricular block, and salves of ventricular premature beats were the most serious rhythm disturbances. The absence of life threatening rhythm disturbances is attributed to the early use of diphenylhydantoin in small frequent doses.

MaleDigoxinInjury controlAccident preventionPhysiologyPoison controlSuicide AttemptedCritical Care and Intensive Care MedicineDigitalis levelElectrocardiographypolycyclic compoundsMedicineHumanscardiovascular diseasesChildbusiness.industrydigestive oral and skin physiologySerum digoxin levelcarbohydrates (lipids)Heart BlockAnesthesiaPhenytoinPotassiumDigoxin intoxicationbusinessSerum potassium levelIntensive care medicine
researchProduct

Closed loop stimulation improve ejection fraction in pediatric patients with pacemaker and ventricular dysfunction

2007

Background: The aim of this prospective study was to evaluate the effect of the closed loop stimulation (CLS) on the ejection fraction in pediatric patients, affected by complete atrioventricular block (CAVB) or CAVB and sinus node dysfunction (SND), with a previously implanted pacemaker (PM) and ventricular dysfunction. The role of electrical therapy in the treatment of pediatric patients with congenital atrioventricular (AV) blocks has been shown. Conventional right ventricular pacing seems to affect ventricular function. Up to now, the feasibility and the long-term results of biventricular pacing in pediatric patients were not entirely clear. Methods: In eight pediatric patients with a p…

MalePacemaker Artificialmedicine.medical_specialtyClosed loop stimulationCLs upper limitsInternal medicineVentricular DysfunctionmedicineHumansProspective StudiesChildProspective cohort studyEjection fractionVentricular functionbusiness.industryCardiac Pacing ArtificialInfantStroke VolumeGeneral MedicineStroke volumeVentricular pacingmedicine.diseaseHeart BlockChild PreschoolCardiologyFemaleCardiology and Cardiovascular MedicinebusinessAtrioventricular block
researchProduct

Is atrial sensing of ventricular far-field signals important in single-lead VDD pacing?

1998

UNLABELLED In single-lead VDD pacing the atrial sensitivity frequently is programmed to sensitive values. Atrial sensing of ventricular far-field signals should be reduced by differential atrial sensing. The aim of the study was to evaluate the effectiveness of this approach. METHODS The study included 10 patients with a single-lead VDD pacemaker (Thera 8948, Lead 5032). The atrial sensitivity was set to its most sensitive value of 0.18 mV and the telemetered intraatrial EGM was continuously recorded. After atrial tracked ventricular pacing, VVI pacing was performed with pacing rates from 100 to 160 beats/min in steps of 10 beats/min and up to 165 beats/min. The peak-to-peak amplitudes of P…

Malemedicine.medical_specialtyPacemaker ArtificialHeart blockAtrial sensingInternal medicinemedicineHumansTelemetrySinus rhythmcardiovascular diseasesAgedbusiness.industryRate dependentCardiac Pacing ArtificialGeneral MedicineVentricular pacingmedicine.diseaseElectrodes ImplantedHeart BlockSingle leadcardiovascular systemVdd pacingCardiologyFemaleCardiology and Cardiovascular MedicinebusinessPacing and clinical electrophysiology : PACE
researchProduct

Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching.

1998

Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of…

Malemedicine.medical_specialtyPacemaker ArtificialTime FactorsParoxysmal atrial fibrillationVentricular stimulationInternal medicineAtrial FibrillationMedicineHumansSinus rhythmIn patientcardiovascular diseasesbusiness.industryP waveCardiac Pacing ArtificialAtrial fibrillationGeneral MedicineMiddle Agedmedicine.diseaseHeart BlockSingle leadAnesthesiacardiovascular systemCardiologyMode switchingFemaleCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesPacing and clinical electrophysiology : PACE
researchProduct

The Role of Cardiac Pacing in Heart Block Complicating Acute Myocardial Infarction

1983

The organization of the Coronary Care Unit and the use of electrocardiographic monitoring have allowed a re-evaluation of the incidence of the atrioventricular conduction disturbances in acute myocardial infarction.

medicine.medical_specialtyCardiac pacingHeart blockbusiness.industryIncidence (epidemiology)Electrocardiography in myocardial infarctionmedicine.diseaseInternal medicinecardiovascular systemmedicineCardiologyCoronary care unitcardiovascular diseasesMyocardial infarctionbusinessAtrioventricular conduction disturbancesAtrioventricular block
researchProduct

Cardiac phenotype in ATP1A3-related syndromes: A multicentre cohort study

2020

ObjectiveTo define the risks and consequences of cardiac abnormalities in ATP1A3-related syndromes.MethodsPatients meeting clinical diagnostic criteria for rapid-onset dystonia-parkinsonism (RDP), alternating hemiplegia of childhood (AHC), and cerebellar ataxia, areflexia, pes cavus, optic atrophy, and sensorineural hearing loss (CAPOS) with ATP1A3 genetic analysis and at least 1 cardiac assessment were included. We evaluated the cardiac phenotype in an Atp1a3 knock-in mouse (Mashl+/−) to determine the sequence of events in seizure-related cardiac death.ResultsNinety-eight patients with AHC, 9 with RDP, and 3 with CAPOS (63 female, mean age 17 years) were included. Resting ECG abnormalities…

medicine.medical_specialtyCerebellar ataxiaHeart blockbusiness.industryAlternating hemiplegia of childhood030204 cardiovascular system & hematologymedicine.disease3. Good healthSudden cardiac death03 medical and health sciences0302 clinical medicineAtrophyATP1A3Internal medicinemedicineCardiologyRepolarizationSensorineural hearing lossHuman medicineNeurology (clinical)medicine.symptombusinessBiology030217 neurology & neurosurgery
researchProduct