Search results for "Heart Block"
showing 9 items of 19 documents
Cardiac pacing in premature infants and neonates: steroid eluting leads and automatic output adaptation
1999
Abstract Background . Appropriate generator and lead selection as well as techniques of implantation are most important aspects of cardiac pacing in the extremely young patient. Here we report the clinical results using a new technique with automatic output adaptation based on evoked response in combination with steroid-eluting epicardial leads in small children. Methods . One neonate and 2 premature infants underwent permanent pacemaker implantation because of congenital high-degree atrioventricular block or postoperative complete heart block, respectively. Steroid-eluting epicardial leads and a multiprogrammable pacemaker with automatic output adaptation were used. Results . Intermuscular…
Episodes of second-degree ventriculo-atrial block during ventricular tachycardia
2017
Complete congenital heart block is associated with increased autoantibody titers against calreticulin.
1996
Complete congenital heart block (CCHB) is associated with anti-Ro/SS-A and anti-La/SS-B antibodies. Calreticulin, a calcium-binding, multi-functional protein of the endoplasmic reticulum with C-terminal KDEL-sequence, is not part of the Ro/SS-A ribonucleoprotein complex. In this study anti-calreticulin autoantibody responses in serum samples from 18 infants with CCHB, their mothers and in a control group of 11 anti-Ro/SS-A or anti-La/SS-B positive infants without heart block and their mothers were analysed. Specific enzyme-linked immunosorbent assays were performed. Nine out of 18 sera with CCHB contained IgG anti-calreticulin antibodies. Four sera of those with IgG antibodies also had IgM …
Massive digoxin intoxication in childhood.
1978
In a 10 year old boy 8 hours after taking about 16 mg beta-acetyl-digoxin a maximum serum digoxin level of 31.8 ng/ml was measured radioimmunologically. This is the highest digitalis level in childhood described to date. The serum potassium level rose to 7.4 mmol/l. Complete atrio-ventricular block, and salves of ventricular premature beats were the most serious rhythm disturbances. The absence of life threatening rhythm disturbances is attributed to the early use of diphenylhydantoin in small frequent doses.
Closed loop stimulation improve ejection fraction in pediatric patients with pacemaker and ventricular dysfunction
2007
Background: The aim of this prospective study was to evaluate the effect of the closed loop stimulation (CLS) on the ejection fraction in pediatric patients, affected by complete atrioventricular block (CAVB) or CAVB and sinus node dysfunction (SND), with a previously implanted pacemaker (PM) and ventricular dysfunction. The role of electrical therapy in the treatment of pediatric patients with congenital atrioventricular (AV) blocks has been shown. Conventional right ventricular pacing seems to affect ventricular function. Up to now, the feasibility and the long-term results of biventricular pacing in pediatric patients were not entirely clear. Methods: In eight pediatric patients with a p…
Is atrial sensing of ventricular far-field signals important in single-lead VDD pacing?
1998
UNLABELLED In single-lead VDD pacing the atrial sensitivity frequently is programmed to sensitive values. Atrial sensing of ventricular far-field signals should be reduced by differential atrial sensing. The aim of the study was to evaluate the effectiveness of this approach. METHODS The study included 10 patients with a single-lead VDD pacemaker (Thera 8948, Lead 5032). The atrial sensitivity was set to its most sensitive value of 0.18 mV and the telemetered intraatrial EGM was continuously recorded. After atrial tracked ventricular pacing, VVI pacing was performed with pacing rates from 100 to 160 beats/min in steps of 10 beats/min and up to 165 beats/min. The peak-to-peak amplitudes of P…
Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching.
1998
Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of…
The Role of Cardiac Pacing in Heart Block Complicating Acute Myocardial Infarction
1983
The organization of the Coronary Care Unit and the use of electrocardiographic monitoring have allowed a re-evaluation of the incidence of the atrioventricular conduction disturbances in acute myocardial infarction.
Cardiac phenotype in ATP1A3-related syndromes: A multicentre cohort study
2020
ObjectiveTo define the risks and consequences of cardiac abnormalities in ATP1A3-related syndromes.MethodsPatients meeting clinical diagnostic criteria for rapid-onset dystonia-parkinsonism (RDP), alternating hemiplegia of childhood (AHC), and cerebellar ataxia, areflexia, pes cavus, optic atrophy, and sensorineural hearing loss (CAPOS) with ATP1A3 genetic analysis and at least 1 cardiac assessment were included. We evaluated the cardiac phenotype in an Atp1a3 knock-in mouse (Mashl+/−) to determine the sequence of events in seizure-related cardiac death.ResultsNinety-eight patients with AHC, 9 with RDP, and 3 with CAPOS (63 female, mean age 17 years) were included. Resting ECG abnormalities…