Search results for "Heat generation"
showing 10 items of 24 documents
MHD free convection in a liquid-metal filled cubic enclosure. II. Internal heating
2002
The buoyancy-driven magnetohydrodynamic flow in a liquid-metal filled cubic enclosure was investigated by three-dimensional numerical simulation. The enclosure was differentially heated at two opposite vertical walls, all other walls being adiabatic, and a uniform magnetic field was applied orthogonal to the temperature gradient and to the gravity vector. The Rayleigh number was 105 and the Prandtl number was 0.0321 (characteristic of Pb–17Li at 573 K). The Hartmann number was made to vary between 102 and 103 and the electrical conductance of the walls between 0 and ∞. The continuity, momentum and enthalpy transport equations, in conjunction with a Poisson equation for the electric potentia…
Comparing different processing methods in apple slice drying. Part 1. Performance of microwave, hot air and hybrid methods at constant temperatures
2019
The drying curves, energy efficiency and colour variations of sliced apples dried at various temperatures and using different techniques were evaluated, i.e. microwave (35, 55 and 65 °C), hot air (35, 55, 65 and 75 °C) and combination of both (65 °C). The microwave (MW) tests also included comparison between air recirculation and continuous inlet of fresh air. Each drying method was evaluated at a fixed temperature level by means of a control system based on infrared thermography. The time required to complete the drying process at 65 °C varied from about 44 min for MW with fresh air ventilation (double with air recirculation), to 122 min for hybrid heating and 238 min for hot air. Drying k…
A procedure to achieve fine control in MW processing of foods
2007
Abstract A two-dimensional analytical model for predicting the unsteady temperature field in a cylindrical shaped body affected by spatially varying heat generation is presented. The dimensionless problem is solved analytically by using both partial solutions and the variation of parameters techniques. Having in mind industrial microwave heating for food pasteurization, the easy-to-handle solution is used to confirm the intrinsic lack of spatial uniformity of such a treatment in comparison to the traditional one. From an experimental point of view, a batch pasteurization treatment was realized to compare the effect of two different control techniques both based on IR thermography readout: t…
A Luminescent Thermometer Exhibiting Slow Relaxation of the Magnetization: Toward Self-Monitored Building Blocks for Next-Generation Optomagnetic Dev…
2019
The development and integration of Single-Molecule Magnets (SMMs) into molecular electronic devices continue to be an exciting challenge. In such potential devices, heat generation due to the electric current is a critical issue that has to be considered upon device fabrication. To read out accurately the temperature at the submicrometer spatial range, new multifunctional SMMs need to be developed. Herein, we present the first self-calibrated molecular thermometer with SMM properties, which provides an elegant avenue to address these issues. The employment of 2,2′-bipyrimidine and 1,1,1-trifluoroacetylacetonate ligands results in a dinuclear compound, [Dy2(bpm)(tfaa)6], which exhibits slow …
Low-Prandtl Number Natural Convection in Volumetrically Heated Rectangular Enclosures - II. Square Cavity, AR=1
2001
Low-Prandtl Number Natural Convection in Volumetrically Heated Rectangular Enclosures - I. Slender Cavity, AR=4
2000
Efficient photo-thermal activation of gold nanoparticle-doped polymer plasmonic switches
2012
International audience; We report on the photo-thermal activation of dielectric loaded plasmonic switches comprised of gold nanoparticle-doped polymer deposited onto a gold film. The plasmonic switches rely on a multi-mode interferometer design and are fabricated by electron beam lithography applied to a positive resin doped with gold nanoparticles at a volume ratio of 0.52%. A cross-bar switching is obtained at telecom wavelengths by pumping the devices with a visible beam having a frequency within the localized surface plasmon resonance band of the embedded nanoparticles. By comparing the switching performances of doped and undoped devices, we show that for the modest doping level we cons…
Temperature elevations in endosseous dental implants and the peri-implant bone during diode-laser-assisted surface decontamination
2002
The aim of the study was to investigate temperature elevations in the implant surface and the peri-implant bone during simulated surface decontamination of endosseous dental implants with an 809 nm semiconductor laser. Stepped cylinder implants were inserted into bone blocks cut from resected pig femurs. An artificial peri-implant bone defect provided access for the irradiation of the implant surface. A 600 micron optic fiber was used at a distance of 0.5 mm from the implant surface. Power output varied between 0.5 and 2.5 W in the cw-mode. Power density was between 176.9 and 884.6 Wcm -2 . The bone block was placed into a 37 degree(s)C water bath in order to simulate in vivo thermal conduc…
Influence of a Magnetic Field on Liquid Metal Free Convection in an Internally Heated Cubic Enclosure
2002
The buoyancy‐driven magnetohydrodynamic flow in a cubic enclosure was investigated by three‐dimensional numerical simulation. The enclosure was volumetrically heated by a uniform power density and cooled along two opposite vertical walls, all remaining walls being adiabatic. A uniform magnetic field was applied orthogonally to the gravity vector and to the temperature gradient. The Prandtl number was 0.0321 (characteristic of Pb–17Li at 300°C), the Rayleigh number was 104, and the Hartmann number was made to vary between 0 and 2×103. The steady‐state Navier–Stokes equations, in conjunction with a scalar transport equation for the fluid's enthalpy and with the Poisson equation for the electr…
Analysis of factors determining thermal changes at osteotomy site in dental implant placement - An in-vitro study
2021
Background Heat generation during osteotomy site preparation is a crucial factor that determines the success of dental implant placement. Among the factors that affect the heat generation, drilling speed, hand pressure and coolant temperature are independent variables. However, a relation between these three parameters and their optimal values required for the maximum outcome has not been studied so far. This study aims at finding out a relation between these factors in order to derive the optimum balance required, using an in vitro study. Material and methods This in vitro experiment was performed on bovine femur. A total of 72 drillings were undertaken with the aid of a physiodispenser mo…