Search results for "Hemodynamic"
showing 10 items of 526 documents
Noninvasive assessment of baroreflex sensitivity in post-MI patients by an open loop parametric model of RR-systolic pressure interactions
2003
Noninvasive evaluation of baroreflex sensitivity is considered an important goal for diagnosis and prognosis in post-MI patients. Methodological approach and physiological measure conditions may be the main causes for the differences found with respect to the standard Phenylephrine test. In this study, three linear parametric models, describing variability and mutual interactions of RR interval and systolic arterial pressure (SAP), were compared in relation to their ability to quantify baroreflex gain, using the Phenylephrine test index (Phe/sub BRS/) as reference. By monovariate autoregressive (AR) model, bivariate AR model and open loop ARXAR model, specific gain indexes (/spl alpha//sub …
[Compensation mechanisms of perioperative anemia].
2002
Neprilysin inhibition, endorphin dynamics, and early symptomatic improvement in heart failure: a pilot study
2020
Altres ajuts: This work was supported in part by Fundació La Marató de TV3 (201516-10, 201502-30), Societat Catalana de Cardiologia, "la Caixa" Banking Foundation. Altres ajuts: PERIS/SLT002-16-00234 Sacubitril/valsartan is a first-in-class angiotensin receptor-neprilysin inhibitor developed for the treatment of heart failure with reduced ejection fraction. Its benefits are achieved through the inhibition of neprilysin (NEP) and the specific blockade of the angiotensin receptor AT1. The many peptides metabolized by NEP suggest multifaceted potential consequences of its inhibition. We sought to evaluate the short-term changes in serum endorphin (EP) values and their relation with patients' p…
Coarctation of the Aorta: Quantitative Analysis by Transesophageal Echocardiography
1987
Summary Transesophageal echocardiography and standard two-dimensional echocardiography were performed in 15 patients with suspected coarctation of the aorta. Aortic diameters and crosssectional areas were determined by means of TEE and compared with clinical findings and catheterization data. The isthmus of the aorta could be imaged in all patients using TEE, but in only seven patients using standard suprasternal echocardiography. Compared with controls, aortic diameters were narrowed in 9 of 15 patients, and cross-sectional areas were reduced in 13 of 15. There was a satisfactory correlation between TEE data and angiographic and hemodynamic data. TEE is a promising method of a diagnosing a…
Computational fluid dynamics simulation to evaluate aortic coarctation gradient with contrast-enhanced CT
2014
Coarctation of aorta (CoA) is a narrowing of the aorta leading to a pressure gradient (Delta P) across the coarctation, increased afterload and reduced peripheral perfusion pressures. Indication to invasive treatment is based on values of maximal (systolic) trans-coarctation Delta P. A computational fluid dynamic (CFD) approach is herein presented for the non-invasive haemodynamic assessment of Delta P across CoA. Patient-specific CFD simulations were created from contrast-enhanced computed tomography (CT) and appropriate flow boundary conditions. Computed Delta P was validated with invasive intravascular trans-CoA pressure measurements. Haemodynamic indices, including pressure loss coeffic…
Epidemiología de la transfusión sanguínea en los Servicios de Medicina Intensiva en España: «Transfusion Day»
2022
Objective To describe the transfusion practice in the ICUs in Spain, according to national and international recommendations (guidelines).DesignProspective, cross-sectional, multi-centre study.ScopeData collection was carried out by means of a questionnaire sent electronically to the Heads of Service of 111 ICUs in Spain.Participants1,448 patients were included, aged 61.8 (SD 15.7) years, 66.2% male, with an SOFA of 4.7 ± 3.8 and average stay of 10.62 ± 17.49 days.VariablesDemographic and clinical variables of the patients were collected, as well as variables related to the transfusion act.ResultsOf the 1,448 patients, 9.9% received al least one transfusion of any blood product, 3.7% fresh …
Simulation of left ventricular outflow tract (LVOT) obstruction in transcatheter mitral valve-in-ring replacement.
2020
Left ventricular outflow tract (LVOT) obstruction is a feared complication of transcatheter mitral valve replacement (TMVR). This procedure leads to an elongation of LVOT in the left ventricle (namely, the neoLVOT), ultimately portending hemodynamic impairment and death. This study sought to understand the biomechanical implications of LVOT obstruction in two patients who underwent TMVR as an "off-label" application of the Edwards SAPIEN 3 (S3) Ultra transcatheter heart valve (THV). A computational framework of TMVR was developed to assess the neoLVOT area and quantify the sub-aortic flow structure. We observed that the annuloplasty ring serves as the key anchor zone of S3 Ultra THV. A good…
A Nonlinear Circulatory Model for Artificial Heart Studies
1983
Animals with total artificial heart replacement (TAH) have survived for up to 9 months with manually controlled driving systems. A certain physiological control is provided by the animals intact peripheral regulation resulting in pathological venous hemodynamics, expressing the needs for a technical automatic control system, replacing the natural sympathetic stimulation and Starlings Law of the heart. A nonlinear dynamic mathematical model of the human cardiovascular system (CVSM) containing the systemic and pulmonary components was outlined and verified, which is employable to analyse the hemodynamic behaviour under normal and abnormal states. By modifying this model, assuming that cardiac…
Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs.
2019
Hemorrhagic shock ranks among the main reasons for severe injury-related death. The loss of circulatory volume and oxygen carriers can lead to an insufficient oxygen supply and irreversible organ failure. The brain exerts only limited compensation capacities and is particularly at high risk of severe hypoxic damage.This article demonstrates the reproducible induction of life-threatening hemorrhagic shock in a porcine model by means of calculated blood withdrawal. We titrate shock induction guided by near-infrared spectroscopy and extended hemodynamic monitoring to display systemic circulatory failure, as well as cerebral microcirculatory oxygen depletion. In comparison to similar models tha…
The influence of dopamine on hemodynamics, microcirculation and renal function in patients with hypnotic drug intoxication
1976
The effect of dopamine on hemodynamics (CO, AoPm, TPR, SV, SW, CVP, PAPm, PAEDP), microcirculation (MBF, PS-product) and renal function (VU, CKI, CNa, CK, Cosm, TcH2O) was studied in 8 patients with hypnotic drug poisoning. With increasing doses of dopamine, cardiac output and heart rate increased and the peripheral resistance decreased. An augmentation of stroke volume and left ventricular stroke work was observed in the low dose range only (200--400 mug/min). With increasing doses, central venous pressure as well as mean pulmonary artery pressure and enddiastolic pulmonary artery pressure decreased. No vasoconstriction was found in muscle tissue vessels even with large doses of dopamine. …