Search results for "Hexafluoride"
showing 10 items of 41 documents
The high overtone and combination levels of SF6 revisited at Doppler-limited resolution: A global effective rovibrational model for highly excited vi…
2017
Abstract Sulfur hexafluoride is an important prototypal molecule for modeling highly excited vibrational energy flow and multi quanta absorption processes in hexafluoride molecules of technological importance. It is also a strong greenhouse gas of anthropogenic origin. This heavy species, however, features many hot bands at room temperature (at which only 30% of the molecules lie in the ground vibrational state), especially those originating from the lowest, v 6 =1 vibrational state. Using a cryogenic long path cell with variable optical path length and temperatures regulated between 120 and 163 K, coupled to Synchrotron Radiation and a high resolution interferometer, Doppler-limited spectr…
Nitrogen broadening of SF6 transitions in the nu3 band
2001
Abstract Nitrogen induced pressure-broadened halfwidths of a number of ν3 transitions of SF6 are calculated using the complex Robert–Bonamy (CRB) formalism. The calculations are made at 200, 250, 296 and 350 K and the temperature dependence of the halfwidths are determined. The intermolecular potential is taken as a sum of the leading electrostatic and Lennard-Jones [6] , [7] , [8] , [9] , [10] , [11] , [12] atom–atom components. The dynamics of the collision process are correct to second order in time. The calculated halfwidths are used to simulate the ν3 spectrum, which is compared to a simulation made using the HITRAN96 halfwidths and measurements made at the Universite Pierre et Marie C…
High-resolution spectroscopy and analysis of the V2 + V3 combination band of SF6 in a supersonic jet expansion
2013
International audience; Sulphur hexafluoride is a very strong greenhouse gas whose concentration is increasing in the atmosphere. It is detected through infrared absorption spectroscopy in the strong ν3 fundamental region. Due to the existence of low-lying vibrational states of this molecule, however, many hot bands arise at room temperature and those are still not known. We present here a contribution to the elucidation of this hot band structure, by analysing the ν2 + ν3 combination band. We use a supersonic jet expansion high-resolution spectrum at a rotational temperature of ca. 25 K that was recorded thanks to the Jet-AILES setup at the Source Optimisée de Lumière d'Energie Intermédiai…
Corrosion and wear resistance of coatings produced on AZ31 Mg alloy by plasma electrolytic oxidation in silicate-based K2TiF6 containing solution: Ef…
2022
Abstract In this research, plasma electrolytic oxidation coatings were prepared on AZ31 Mg alloy in a silicate-based solution containing K2TiF6 using bipolar and soft sparking waveforms with 10, 20, and 30% cathodic duty cycles. The coatings displayed a net-like surface morphology consisted of irregular micro-pores, micro-cracks, fused oxide particles, and a sintered structure. Due to the incorporation of TiO2 colloidal particles and the cathodic pulse repair effect, most of the micro-pores were sealed. Long-term corrosion performance of the coatings was investigated using electrochemical impedance spectroscopy during immersion in 3.5 wt.% NaCl solution up to 14 days. The coating grown by t…
Absorption spectrum of the and electronic transitions of ReF6
1999
Abstract The absorption spectra of the near-infrared and ultraviolet bands of ReF6 have been recorded with a commercial spectrophotometer. The vibronic assignments previously published by different authors are critically revised. A non-perturbative method has been used to calculate the linear Jahn–Teller levels for the ν5 mode in the ground electronic state. Some new vibronic parameter values are derived. The ν5 linear Jahn–Teller parameter in the X G′ g electronic state is found to be D5=0.103(9). The ultraviolet absorption spectrum has enabled us to determine relatively accurate values of the crystal-field (10Dq) and spin-orbit (ζd) parameters.
Contrast-Enhanced Ultrasonography With SonoVue
2009
Objective. We investigated the ability of contrast-enhanced ultrasonography with SonoVue (Bracco SpA, Milan, Italy), a sulfur hexafluoride microbubble contrast agent, to reveal differences between benign and malignant focal splenic lesions. Methods. In a prospective study we investigated 35 lesions in 35 patients (24 male and 11 female; mean age ± SD, 54 ± 15 years) with focal splenic lesions detected by B-mode ultrasonography. After intravenous injection of 1.2 to 2.4 mL of SonoVue, the spleen was examined continuously for 3 minutes using low–mechanical index ultrasonography with contrastspecific software. The final diagnosis was established by histologic examination, computed tomography, …
Characterization of hypoechoic focal hepatic lesions in patients with fatty liver: diagnostic performance and confidence of contrast-enhanced ultraso…
2007
The objective of this study was to assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) to characterize hypoechoic focal hepatic lesions (HFHL) in fatty liver (FL). A study group of 105 patients with FL and 105 HFHLs (52 malignant and 53 benign) underwent CEUS after SonoVue administration. Two blinded readers independently reviewed baseline ultrasound (US) and CEUS scans and classified each lesion as malignant or benign on a five-point scale of confidence, and recorded whether further imaging work-up was needed. Sensitivity, specificity, areas under the receiver operating characteristic (ROC) curve (A (z)), and interobserver agreement were calculated. We observed that th…
Hepatic focal nodular hyperplasia: contrast-enhanced ultrasound findings with emphasis on lesion size, depth and liver echogenicity
2010
To correlate contrast-enhanced ultrasound (CEUS) findings of hepatic focal nodular hyperplasia (FNH) with lesion size, depth and liver echogenicity and to compare CEUS with baseline US. Two radiologists evaluated baseline US and CEUS examinations of 92 FNHs (mean size: 3.1 +/- 1.7 cm) in 71 patients (59 women and 12 men) to detect the "spoke-wheel" sign, central scar and feeding vessel. The FNHs were grouped and analysed by dimension, depth and liver echogenicity. At least one sign could be detected at CEUS in 27 out of 36 (75%) FNHs larger than 3 cm and in 17 out of 56 (30%) FNH measuring 3 cm or less (p 0.05) as well as between CEUS or baseline US/CD with regard to lesion size, depth or l…
Indeterminate focal liver lesions incidentally discovered at gray-scale US: role of contrast-enhanced sonography.
2011
OBJECTIVES: to assess the role of contrast-enhanced ultrasound (CEUS) in the characterization of focal liver lesions (FLLs) incidentally discovered but indeterminate at gray-scale ultrasound (US). MATERIALS AND METHODS: one hundred forty-two consecutive patients with 174 FLLs (169 benign and 5 malignant) incidentally discovered but indeterminate at gray-scale US, underwent CEUS after the administration of SonoVue. Two readers independently reviewed CEUS scans and: (1) classified each lesion as malignant or benign on a 5-point scale of confidence by means of definite diagnostic criteria; (2) provided if possible a specific diagnosis; (3) were requested if further imaging was needed for lesio…
Study of neurinomas with ultrasound contrast media: review of a case series to identify characteristic imaging patterns
2011
The aim of this study was to evaluate whether there exists a characteristic distribution pattern of vessels within neurinomas that may be used to characterise this type of lesion by employing a contrast-specific ultrasound technique.Between January 2003 and May 2010, 66 suspected neurinomas were evaluated according to their sonographic features (solid fusiform mass with well-defined margins located in direct continuity with the nerve that was not always discernible and heterogeneous as a result of the presence of small cystic areas or calcifications). The lesions were examined using a sonographic contrast medium consisting of sulphur hexafluoride microbubbles and equipment with dedicated co…