Search results for "Hexis"
showing 10 items of 11 documents
Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.
2005
To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany.In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometri…
Special Uses of Viscoelastics
2000
The possibilities of viscoelastic use in phacoemulsification will be outlined in the following figures. Many ophthalmic surgeons apply viscoelastic substances in capsulorhexis to achieve a deep anterior chamber and extend the pupillary space (with a small pupil). Care must be taken during injection so that aqueous is permitted to flow out. When using a paracentesis to inject viscoelastic (Fig. 59), it must be big enough to allow aqueous outflow. For complete aqueous exchange in the anterior chamber, it is advisable to inject the viscoelastic into the opposite chamber angle.
Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery.
2007
Purpose To determine whether implantation of a microincision intraocular lens (IOL) with a modified anterior surface, designed to compensate for the positive spherical aberration of the cornea in eyes of cataract patients, results in improved pseudophakic quality of vision in pseudophakic eyes after biaxial microincision phacoemulsification. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods In a nonrandomized parallel cohort investigation, the visual performance of 52 eyes of 52 patients unilaterally implanted with the aspherical Acri.Smart 36 A IOL (Acri.Tec) were compared with those of 25 eyes of 25 age-matched patients unilaterally implanted with…
Effect of large positioning holes on capsule fixation of plate-haptic intraocular lenses
2000
Abstract Purpose To compare the centration and fixation of silicone plate-haptic intraocular lenses (IOLs) with different-sized positioning holes. Setting Eye Clinic of the Johannes Gutenberg-University Mainz, Mainz, Germany. Methods In a prospective randomized study, 51 Chiroflex C10 and 56 Chiroflex C11 IOLs were implanted under standardized conditions by the same surgeon. The IOL position was documented at the end of surgery and by retroillumination on the first day and 5 months postoperatively. The positioning-hole area was evaluated by ultrasound biomicroscopy (50 MHz) 5 months postoperatively. Results One day postoperatively, no IOL in either group was decentered more than 1.0 mm. Aft…
Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation
2003
Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…
Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.
2005
To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…
Emotions and epistemology: a path for reconsideration in the 21st century
2017
The present paper explores the gap between sensations and emotions in the global capitalism. We held the thesis that there are diverse ways to systematise the theoretical orientations on which the studies on the body/emotion are based; a possible one, having in mind the Latin American context and without intent of exhaustiveness, is the following: a) a line of work connected to Foucault and his concepts of control, discipline, and technologies of the self; b) an approach connected to Bourdieu and his notions of habitus, body hexis, and social fields; c) a set of investigations in the field of biopolitics referring to Esposito and Agamben on the one hand, and to Negri and Hardt on the other;…
Aristote. On Hexis
2010
International audience
The Dynamic ofHexisin Aristotle's Philosophy
2011
(2011). The Dynamic of Hexis in Aristotle's Philosophy. Journal of the British Society for Phenomenology: Vol. 42, Habit, pp. 6-17.
The Dynamic of Hexis in Aristotle’s Philosophy
2011
International audience