Search results for "High Pressure"
showing 10 items of 894 documents
Strategies for the enantiomeric determination of amphetamine and related compounds by liquid chromatography.
2002
This paper summarizes recent research on the stereospecific analysis of amphetamine, its analogs and metabolites, by liquid chromatography. The different methods proposed have been evaluated and compared in terms of resolution power, time of analysis, sensitivity, or potential for automation. Chiral derivatization, followed by separation of the diastereomers formed in achiral chromatographic systems, is still the method preferred for the analysis of amphetamines at trace levels, as derivatization also improves analyte detectability. This is the method of choice for the enantiomeric analysis of amphetamines at the low concentrations typically encountered in biological samples. In recent year…
Wide-range screening of banned veterinary drugs in urine by ultra high liquid chromatography coupled to high-resolution mass spectrometry
2012
In this work, an ultra high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) methodology is proposed for the multi-class multi-residue screening of banned and unauthorized veterinary drugs in bovine urine, using an Orbitrap Exactive™ analyzer working at a resolving power of 50,000 FWHM in full scan, both in positive and negative mode. The method currently covers 87 analytes belonging to different families such as steroid hormones, β-agonists, resorcylic acid lactones (RAL), stilbens, tranquillizers, nitroimidazoles, corticosteroids, NSAIDs, amphenicoles, thyreostatics and other substances such as dapsone. A database including the elemental composition, the po…
Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hy…
2016
Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and …
Comprehensive analysis of airborne pesticides using hard cap espresso extraction-liquid chromatography-high-resolution mass spectrometry
2017
A hard cap espresso extraction procedure has been developed to recover airborne pesticides in particulate matter trapped in filters. This extraction step was made for 20s at 72°C and 19bar using 50mL of 20% (v/v) acetonitrile in water. After that, based on NaCl salting out, extracts were concentrated 22 times and analysed by ultra-high performance liquid chromatography - high resolution mass spectrometry. 35 pesticides were evaluated, as a proof of concept, being validated the whole methodology and compared the extraction method with that based on microwave assisted extraction for 20min. In short, the method avoids cross-contamination of samples, it is relatively fast and consumes only 10mL…
Applicability of hybrid linear ion trap-high resolution mass spectrometry and quadrupole-linear ion trap-mass spectrometry for mycotoxin analysis in …
2012
Abstract Recent developments in mass spectrometers have created a paradoxical situation; different mass spectrometers are available, each of them with their specific strengths and drawbacks. Hybrid instruments try to unify several advantages in one instrument. In this study two of wide-used hybrid instruments were compared: hybrid quadrupole-linear ion trap-mass spectrometry (QTRAP ® ) and the hybrid linear ion trap-high resolution mass spectrometry (LTQ-Orbitrap ® ). Both instruments were applied to detect the presence of 18 selected mycotoxins in baby food. Analytical parameters were validated according to 2002/657/CE. Limits of quantification (LOQs) obtained by QTRAP ® instrument ranged …
Identification of fish species by reversed-phase high-performance liquid chromatography with photodiode-array detection
1998
A method for the separation of sarcoplasmic fish proteins by RP-HPLC is described. The procedure revealed significant differences useful for reliable identification of fish species. Sixteen of the most common Finnish freshwater fish species were differentiated by species-specific HPLC chromatograms obtained using photodiode-array detection (PAD) at 200-350 nm. The analytical column was a Hi-Pore RP-304 reversed-phase column. The separation was performed by a linear gradient of acetonitrile and water with a small amount of trifluoracetic acid (TFA). Star-symbol plots were constructed from the chromatograms to visualize the data. Clearly different HPLC protein profiles for most fish species w…
Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers…
2014
An efficient ultra high performance liquid chromatography (UHPLC)-time-of-flight high resolution mass spectrometry (TOF-HRMS) method was elaborated for the determination of hexabromocyclododecane (HBCD) diastereomers in fish samples and compared against UHPLC-Orbitrap-HRMS and UHPLC-triple quadrupole (QqQ) tandem MS (MS/MS) techniques. The TOF-HRMS analyzer was operated at high resolution (>10000 full width at half maximum (FWHM)) with scanning the m/z range from 600 to 700, to achieve picogram quantitation limits. The effects of various operational parameters on the instrumental response were systematically investigated. Evaluation of the influence of sample clean-up procedure steps on sig…
High-pressure and high-temperature X-ray diffraction studies of scheelite BaWO4
2009
International audience; We carried out high-pressure (HP) and high-temperature (HT) in situ ADXRD synchrotron measurements in barium tungstate (BaWO4 ) up to 7.5 GPa and 800 K. Coexistence of the scheelite and fergusonite structures was found beyond 7 GPa, both at room temperature and HT, suggesting a polymorphism zone in the P –T phase diagram. The experiments are complemented by thermodynamic calculations within the quasi-harmonic approximation. At ambient pressure, a volume thermal expansivity of 9.5 × 10− 6 K−1 was obtained for scheelite BaWO4 . At HP, the thermal expansivity of the fergusonite doubles that of scheelite. Theoretical equation of state curves at HP and HT are also present…
Optical and Acoustic Vibrations Confined in Anatase TiO2 Nanoparticles under High-Pressure
2014
International audience; The effect of an applied high pressure on the optical and acoustic vibrations of small anatase TiO2 nanoparticles is studied using Raman scattering. All the Raman peaks show a significant variation of their frequency with pressure, except for the low-frequency peak which is due to acoustic vibrations confined in the nanoparticles. These variations (or lack thereof) are compared to first-principles calculations of the stiffness tensor and phonons of bulk anatase TiO2 as a function of pressure. In particular, the variation of the shape of the low-frequency peak is explained by the increase of the elastic anisotropy of anatase TiO2 as pressure is increased.
Determination of fatty alcohol ethoxylates and alkylether sulfates by anionic exchange separation, derivatization with a cyclic anhydride and liquid …
2011
A method for the separation, characterization and determination of fatty alcohol ethoxylates (FAE) and alkylether sulfates (AES) in industrial and environmental samples is described. Separation of the two surfactant classes was achieved in a 50:50 methanol-water medium by retaining AES on a strong anionic exchanger (SAX) whereas most FAE were eluted. After washing the SAX cartridges to remove cations, the residual hydrophobic FAE were eluted by increasing methanol to 80%. Finally, AES were eluted using 80:20 and 95:5 methanol-concentrated aqueous HCl mixtures. Methanol and water were removed from the FAE and AES fractions, and the residues were dissolved in 1,4-dioxane. In this medium, este…