Search results for "High Pressure"
showing 10 items of 894 documents
An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation.
2002
A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fr…
Homochiral Metal-Organic Frameworks for Enantioselective Separations in Liquid Chromatography
2020
Selective separation of enantiomers is a substantial challenge for the pharmaceutical industry. Chromatography on chiral stationary phases is the standard method, but at a very high cost for industrial-scale purification due to the high cost of the chiral stationary phases. Typically, these materials are poorly robust, expensive to manufacture, and often too specific for a single desired substrate, lacking desirable versatility across different chiral analytes. Here, we disclose a porous, robust homochiral metal–organic framework (MOF), TAMOF-1, built from copper(II) and an affordable linker prepared from natural l-histidine. TAMOF-1 has shown to be able to separate a variety of model…
Interpretive optimisation of organic solvent content and flow-rate in the separation of β-blockers with a Chromolith RP-18e column
2009
The chromatographic performance of a Chromolith RP-18e column was comprehensively examined for a group of basic drugs (beta-blockers), eluted with isocratic ACN-water mixtures at increasing flow-rate up to 6 mL/min. As the flow-rate increases at fixed mobile phase composition, peak distribution (selectivity) is maintained, but the relative peak widths increase. This reduces the resolution below satisfactory values for closely eluting compounds. With the monolithic column, flow-rate becomes thus an important factor to be optimised, in addition to the mobile phase composition. Since, theoretically, retention factors (k) are independent of the flow-rate, the classical quadratic model relating …
Net analyte signal as a deconvolution-oriented resolution criterion in the optimisation of chromatographic techniques
2003
The performance of two multivariate calibration measurements, multivariate selectivity (SEL(s)) and scalar net analyte signal (scalar NAS), as chromatographic objective functions (COFs), was investigated. Since both assessments are straightforwardly related to the quantification of analytes in the presence of interferents, they were expected to confer new features in the optimisation of compound resolution, not present in conventional assessments. These capabilities are especially interesting in situations of low resolution, where peak deconvolution becomes an attractive alternative. For comparison purposes, chromatographic resolution (R(s)) and peak purity (p(s)) were used as reference COF…
Robust interpretive optimisation in high-performance liquid chromatography considering uncertainties in peak position.
2005
In the context of interpretive chromatographic optimisation, robustness is usually calculated by introducing deliberated shifts in the nominal optimal conditions and evaluating their effects on the monitored objective function, mimicking thus the experimental procedures used in method validation. However, such strategy ignores a major source of error: the uncertainties associated to the modelling step, that may give rise to deceiving results when conditions that were expected to yield baseline separation are reproduced in the chromatograph. Two approaches, based on the peak purity concept, are here proposed to evaluate the robustness of the objective function under the perspective of measur…
Complete decontamination and regeneration of DNA purification silica colum
2008
Silica columns are among the most used DNA purification systems, allowing a good yield of high-quality nucleic acids without organic extractions. Silica column regeneration protocols reported up to now to remove DNA traces are time-consuming, and their effectiveness on genomic DNA has not been demonstrated. Here we report a very rapid regeneration procedure that ensures no DNA carryover, independent of its size, without impairing column efficiency. The method takes advantage of the improved DNA removal by low concentrations of Triton X-100.
Critical study of and improvements in chromatographic methods for the analysis of type B trichothecenes
2001
Various analytical methods used in the analysis of type B trichothecenes (deoxynivalenol, nivalenol, 3- and 15-acetyldeoxynivalenol) in cereals were compared and optimised in this work. These methods use either GC-electron-capture detection (ECD) of trimethylsilyl, trifluoroacetyl and heptafluorobutyryl derivatives or HPLC with UV or photodiode array detection of analytes. A new HPLC procedure using fluorescence detection prior derivatisation with coumarin-3-carbonyl chloride has been also tested. Five extraction solvents and two solid-phase extraction cartridges (silica, Florisil) plus a especial clean-up column (MycoSep 225) were compared in order to obtain the best recovery of the mycoto…
Retrospective screening of pesticide metabolites in ambient air using liquid chromatography coupled to high-resolution mass spectrometry
2015
A new methodology for the retrospective screening of pesticide metabolites in ambient air was developed, using liquid chromatography coupled to Orbitrap high-resolution mass spectrometry (UHPLC-HRMS), including two systematic workflows (i) post-run target screening (suspect screening) and (ii) non-target screening. An accurate-mass database was built and used for the post-run screening analysis. The database contained 240 pesticide metabolites found in different matrixes such as air, soil, water, plants, animals and humans. For non-target analysis, a "fragmentation-degradation" relationship strategy was selected. The proposed methodology was applied to 31 air samples (PM10) collected in the…
Study of conformational effects of recombinant interferon gamma adsorbed on a non-porous reversed-phase silica support.
1995
Abstract Reversed-phase chromatography is a powerful method for separating recombinant interferon γ and one of its analogues differing only by a single amino acid residue. Structural differences of the proteins explain this separation ability as demonstrated from adsorption studies on a non-porous reversed-phase support. To reveal the structural differences occurring in the adsorbed state, two different and independent methods were employed. The variation of the retention with the slope of the linear gradient gave information about the molecular contact area of the protein with the support. For different experimental conditions, these data were correlated with the adsorbent capacities measu…
Classification of Extra Virgin Olive Oils Produced at La Comunitat Valenciana According to Their Genetic Variety Using Sterol Profiles Established by…
2009
A method to classify extra virgin olive oils (EVOOs) according to their genetic variety using sterol profiles obtained by high-performance liquid chromatography (HPLC) with mass spectrometry (MS) detection has been developed. Sterol extracts were chromatographed on a dC18 Atlantis column (100x3 mm, 3 microm) with a gradient of acetonitrile/water (0.01% acetic acid) at a flow rate of 1.0 mL min(-1) and positive-ion mode MS detection. Using linear discriminant analysis of the HPLC-MS data (extracted ion chromatograms), EVOO samples belonging to six genetic varieties cultivated at La Comunitat Valenciana, Spain (Arbequina, Borriolenca, Canetera, Farga, Picual, and Serrana), were correctly clas…