Search results for "High resolution"
showing 10 items of 249 documents
Digital orthophotos at a scale of 1:5000 from high resolution satellite images
2004
This paper describes the first results of a study, carried out within the national research program “Cofin2001”, on the potential use of high resolution satellite images for making digital orthophotos at a scale of 1:5000 and 1:10,000. Particularly, images from IKONOS II and QuickBird of four different types of areas were employed: the first area is the city of Palermo, a greatly urbanized area; the second area is the extra-urban territory near the town of Contessa Entellina in south-western Sicily; the third area is the famous tourist resort of Scopello, in the western Sicily; the last area is the Caselle Airport, a flat zone near Torino. The first three images were orthorectified by using…
Red and Far-Red Fluorescence Emission Retrieval from Airborne High-Resolution Spectra Collected by the Hyplant-Fluo Sensor
2018
The contribution presents the development and testing of a fluorescence retrieval scheme based on the ESA's FLuorescence EXplorer mission concept. The algorithm employs on a coupled surface-atmosphere forward model at oxygen absorption bands: i) the atmospheric effect is computed by MODTRAN5; ii) the surface reflectance and fluorescence are modeled by means of the Spectral Fitting approach. The algorithm, previously tested on numerical simulations, was further implemented and optimized to process real observations collected by the FLEX airborne demonstrator HyPlant. The retrieval scheme has been tested on a number of flight lines collected in several locations, different ecosystems types, a…
Evaluation of mycotoxins and their metabolites in human breast milk using liquid chromatography coupled to high resolution mass spectrometry
2014
Humans can be exposed to mycotoxins through the food chain. Mycotoxins are mainly found as contaminants in food and could be subsequently excreted via biological fluids such as urine or human breast milk in native or metabolised form. Since breast milk is usually supposed as the only food for new-borns, the occurrence of mycotoxins in thirty-five human milk samples was evaluated by a newly developed method based on QuEChERS extraction and UHPLC-HRMS detection. The method described here allows the detection of target mycotoxins in order to determine the quality of this initial feeding. The method has been fully validated, with recoveries ranging from 64% to 93% and relative standard deviatio…
Review of High Resolution Thermal Infrared Applications and Requirements: The Fuegosat Synthesis Study
2013
High resolution thermal infrared remote sensing can have a wide range of applications. In this chapter we describe the different applications and requirements identified after a revision study in the framework of the Fuegosat Synthesis Study (FSS). This project was funded by the European Space Agency (ESA), and the three main objectives were: (i) review of applications and analyses for user requirements, (ii) consolidation of user requirements over a broad range of applications, and (iii) matching of user requirements and industry concepts to identify and outline a set of potential mission scenarios and their corresponding requirements. This chapter focuses on issues (i) and (ii). These obj…
Detection and mapping of Posidonia oceanica dead matte by high-resolution acoustic imaging
2009
A high-resolution echosounder was used to acquire seismo-acoustic records of P. oceanica dead matte patches in the Gulf of Palermo. Seismo-acoustic profiling enabled detection of dead matte structures that are invisible to visual inspection, being hidden by variable layers of sandy sediment. The thickness of the dead matte measured reaches a maximum of 2.2 m. The mean volume of the matte per unit area of seabed surface (MEIx) varies from 0.2 to 2.2 m 3 /m 2 , with an average value of 1.6 m 3 /m 2 and a total volume estimated at 73,000 m 3 . From literature data and from the volume of dead matte calculated in the present work we estimated that total carbon accumulated in the matte is about 2…
The summit part of Mount Etna revealed by High Resolution DC Electrical Resistivity Tomography coupled with complementary geophysical and soil gas te…
2016
Between 25 June and 13 July 2015 a very deep ERT profile (Pole-Dipole configuration, 40m spacingbetween electrodes and a remote electrode located at ~10km from the acquisition points) has been performedin the framework of the “MED-SUV” Project. Self-potential, soil gas concentrations (CO2, 222Rn, 220Rn, He,H2 and CH4) and soil temperature measurements were coupled to the ERT profile with a spacing of 20m(except for Rn: 40m). The NE-SW profile crossed Etnas summit craters in the middle of the 5720m ERTtotal length. Six roll along protocols of . of the dispositive (600m out of 2520m tot) have been carried outand, for the first time, a high resolution DC ERT profile reached the noticeable inve…
ATLAS
2020
The book provides a comprehensive overview of high-resolution and high-definition anorectal manometry (HRAM/HDAM), showing the possible benefits of a wider use of these techniques in clinical practice, as well as their limitations. Although these techniques provide fresh insights into anorectal function and offer a new perspective on the pathophysiologic mechanisms of many defecation disturbances, there is a need to clarify whether their use has beneficial effects on clinical management compared to conventional manometry. There is still a considerable way to go to gain the clinical diffusion of esophageal HRM, which has become the gold standard in studying esophageal motility. Indeed, many …
Multi-temporal and Multi-source Remote Sensing Image Classification by Nonlinear Relative Normalization
2016
Remote sensing image classification exploiting multiple sensors is a very challenging problem: data from different modalities are affected by spectral distortions and mis-alignments of all kinds, and this hampers re-using models built for one image to be used successfully in other scenes. In order to adapt and transfer models across image acquisitions, one must be able to cope with datasets that are not co-registered, acquired under different illumination and atmospheric conditions, by different sensors, and with scarce ground references. Traditionally, methods based on histogram matching have been used. However, they fail when densities have very different shapes or when there is no corres…
Self-limiting and complete oxidation of silicon nanostructures produced by laser ablation in water
2016
Oxidized Silicon nanomaterials produced by 1064 nm pulsed laser ablation in deionized water are investigated. High-resolution transmission electron microscopy coupled with energy dispersive X-ray spectroscopy allows to characterize the structural and chemical properties at a sub-nanometric scale. This analysis clarifies that laser ablation induces both self-limiting and complete oxidation processes which produce polycrystalline Si surrounded by a layer of SiO2 and amorphous fully oxidized SiO2, respectively. These nanostructures exhibit a composite luminescence spectrum which is investigated by time-resolved spectroscopy with a tunable laser excitation. The origin of the observed luminescen…
Performance of Radiomics Features in the Quantification of Idiopathic Pulmonary Fibrosis from HRCT.
2020
Background: Our study assesses the diagnostic value of different features extracted from high resolution computed tomography (HRCT) images of patients with idiopathic pulmonary fibrosis. These features are investigated over a range of HRCT lung volume measurements (in Hounsfield Units) for which no prior study has yet been published. In particular, we provide a comparison of their diagnostic value at different Hounsfield Unit (HU) thresholds, including corresponding pulmonary functional tests. Methods: We consider thirty-two patients retrospectively for whom both HRCT examinations and spirometry tests were available. First, we analyse the HRCT histogram to extract quantitative lung fibrosis…