Search results for "High voltage"
showing 10 items of 78 documents
A fuzzy-logic based evolutionary multiobjective approach for automated distribution networks management
2004
In this paper, a methodology to treat constrained scheduling problems based on the repeated application of a fuzzy-logic-based multiobjective algorithm is presented. The application domain is that of automated distribution systems management. In particular, the problem of voltage regulation and power loses minimization is here considered. The classical formulation of the problem of optimal control of shunt capacitor banks and under load tap changers, ULTC, located at high voltage/medium voltage (HV/MV) substations has been coupled with the optimal control of tie-switches and capacitor banks on the feeders of a large radially operated meshed distribution system with the aim of attaining mini…
New Multilevel Inverter Topology with Reduced Component Count
2019
This paper introduces a new topology of modular multilevel inverters, being suitable in medium and high voltage applications. As compared to the existing circuits, the proposed topology has advantages of high ‘levels/components’ ratio, increasing the output voltage levels without increasing the voltage stress across the used switches, structure simplicity, isolation features, and modularity. These merits allow it to fit well in high-reliability medium-power applications, which require fast troubleshooting and maintenance flexibility. Operating principles of the proposed scheme are detailed in low frequency and pulse width modulation. Simulation and experimental results validate the effectiv…
A pulsed high-voltage decelerator system to deliver low-energy antiprotons
2021
International audience; The GBAR (Gravitational Behavior of Antihydrogen at Rest) experiment at CERN requires efficient deceleration of 100 keV antiprotons provided by the new ELENA synchrotron ring to synthesize antihydrogen. This is accomplished using electrostatic deceleration optics and a drift tube that is designed to switch from -99 kV to ground when the antiproton bunch is inside – essentially a charged particle “elevator” – producing a 1 keV pulse. We describe the simulation, design, construction and successful testing of the decelerator device at -92 kV on-line with antiprotons from ELENA.
Ion-Induced Energy Pulse Mechanism for Single-Event Burnout in High-Voltage SiC Power MOSFETs and Junction Barrier Schottky Diodes
2020
Heavy-ion data suggest that a common mechanism is responsible for single-event burnout (SEB) in 1200-V power MOSFETs and junction barrier Schottky (JBS) diodes. Similarly, heavy-ion data suggest a common mechanism is also responsible for leakage current degradation in both devices. This mechanism, based on ion-induced, highly localized energy pulses, is demonstrated in simulations and shown to be capable of causing degradation and SEB for both the MOSFETs and JBS diodes.
The MuPix System-on-Chip for the Mu3e Experiment
2016
Nuclear instruments & methods in physics research / A 845, 194 - 198 (2016). doi:10.1016/j.nima.2016.06.095
Efficiency and timing performance of the MuPix7 high-voltage monolithic active pixel sensor
2018
The MuPix7 is a prototype high voltage monolithic active pixel sensor with 103 times 80 um2 pixels thinned to 64 um and incorporating the complete read-out circuitry including a 1.25 Gbit/s differential data link. Using data taken at the DESY electron test beam, we demonstrate an efficiency of 99.3% and a time resolution of 14 ns. The efficiency and time resolution are studied with sub-pixel resolution and reproduced in simulations.
High voltage conditioning of the electrostatic deflector of MARA
2016
Abstract MARA is a new recoil mass separator in the Accelerator Laboratory of University of Jyvaskyla (JYFL-ACCLAB) with a mass resolving power of 250 and an ion-optical configuration of QQQD E D M . In this paper the construction, control and conditioning of its electrostatic deflector are described. The deflector was designed for voltages up to 500 kV accross the gap, corresponding to a 3.6 MV/m field, to accomodate fusion reactions with inverse kinematics. Titanium electrodes with a beam dump opening in the anode are used. The conditioning procedure, which has been used repeatedly to take the deflector to 450 kV, is described, along with the safety systems and precautions that are in pla…
T2-beta-spectroscopy at KATRIN and the challenge of controlling the electrostatic potentials
2013
Abstract The KATRIN-Collaboration at KIT-Karlsruhe is setting up a huge electrostatic spectrometer in order to search for the absolute value of the neutrino mass from the beta-spectrum of molecular tritium with a sensitivity limit of 0.2 eV. Apart from high intensity, high resolution and low background, this goal requires control of the 18.6 kV filter potential on the ppm level. The paper starts with discussing the impact of uncertainties of beta-endpoint, energy loss and filter potential on the uncertainty of the neutrino mass. Then it describes the various measures for controlling the applied high voltage as well as the potential distribution within the spectrometer and the gaseous tritiu…
A frequency-output fiber optic voltage sensor with temperature compensation for power systems
2003
Abstract We present a frequency-output fiber optic voltage sensor for power systems with temperature compensated response. The sensor employs PZT-type ceramic tubes, which are interrogated by a length of single-mode fiber coiled onto the tubes and a Mach–Zehnder interferometer. The combination of piezoelectric tubes with properties exhibiting opposite behavior to temperature changes is successfully exploited to passively compensate the temperature sensitivity of the sensor. The prototype reported here exhibits a resolution of 13 mV rms and the deviations of the sensor’s response due to temperature changes are within 1% over the temperature range between −30 and 70 °C. The device presented h…
Legri Instrument Health. A Historical Review
2001
LEGRI has been operating successfully on MINISAT-01 since its switch-on the 22nd of May 1997. HouseKeeping (HK) data have been continuously received for nearly two years by LEGRI SOC in Valencia, and subsequently checked on a daily basis and then stored for long term monitoring analysis. LEGRI HouseKeeping data include three critical operating parameters: temperature, power and polarisation voltages. Six temperature sensors are spread over the different LEGRI units: Detector Unit, Data Processing Unit, High Voltage Unit and Star Sensor. Voltages are measured at eight different points. Detector Unit temperature and polarisation voltage are the critical parameters for LEGRI operation. Solid s…