Search results for "High-Dose"

showing 10 items of 25 documents

European Guidelines (S1) on the use of high‐dose intravenous immunoglobulin in dermatology

2016

Background The treatment of severe dermatological autoimmune diseases and toxic epidermal necrolysis (TEN) with high-dose intravenous immunoglobulin (IVIg) is a well-established procedure in dermatology. As treatment with IVIg is usually considered for rare clinical entities or severe clinical cases, the use of immunoglobulin is not generally based on data from randomized controlled trials that are usually required for the practice of evidence-based medicine. Owing to the rarity of the indications for the use of IVIg, it is also unlikely that such studies will be available in the foreseeable future. Because the high costs of IVIg treatment also limit its first-line use, the first clinical g…

0301 basic medicinemedicine.medical_specialtyMEDLINEHigh dose intravenous immunoglobulin610 Medicine & healthEuropean Guidelines (S1) high-dose intravenous immunoglobulinDermatologySkin DiseasesDrug Administration Schedulelaw.inventionAutoimmune Diseases2708 Dermatology030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineRandomized controlled triallawhemic and lymphatic diseasesintravenous immunoglobulinmedicineHumanshigh-doseEvidence-Based MedicineDose-Response Relationship Drugbusiness.industryDermatological diseases10177 Dermatology ClinicImmunoglobulins Intravenous2725 Infectious DiseasesEvidence-based medicinemedicine.diseaseDermatologyToxic epidermal necrolysisEuropeInfectious Diseases030104 developmental biologyEuropean Guidelines (S1)Dermatology clinicStevens-Johnson SyndromeInjections IntravenousEuropean Guidelines (S1) high-dose intravenous immunoglobulin dermatologyDrug MonitoringbusinessJDDG: Journal der Deutschen Dermatologischen Gesellschaft
researchProduct

Criteria for defining a complete remission in acute myeloid leukaemia revisited. An analysis of patients treated in HOVON-SAKK co-operative group stu…

2005

Complete remission (CR) in patients with acute myeloid leukaemia (AML) is the primary endpoint for the evaluation of induction treatment and treatment strategies. However, the choice and application of the criteria for a haematological CR can often become a subject of debate because of regeneration more than 5% blasts may be present at the time of response evaluation; platelet and neutrophil recovery may be incomplete and marrow cellularity can vary. This study examined the individual parameters for CR in 1250 adult patients with de novo AML treated according to three successive study protocols. Patients with < or =5% blasts showed the best overall survival (OS) and the lowest relapse risk …

AdultMaleRiskmedicine.medical_specialtyPathologyAdolescentcomplete remissionMINIMAL RESIDUAL DISEASEDIAGNOSISGastroenterologyTHERAPYDisease-Free SurvivalAMLRecurrencehemic and lymphatic diseasesInternal medicineAntineoplastic Combined Chemotherapy ProtocolsmedicineClinical endpointHumansPlateletacute myeloid leukaemiaLymphocyte CountProportional Hazards ModelsrevisedHematologycriteriaProportional hazards modelbusiness.industryINDUCTIONRemission InductionCancerHematologyMiddle AgedCOLONY-STIMULATING FACTORmedicine.diseaseMinimal residual diseaseCANCERHIGH-DOSE CYTARABINELeukemiamedicine.anatomical_structureLeukemia MyeloidAcute DiseaseFemaleBone marrowbusinessBritish Journal of Haematology
researchProduct

Analysis of thiamine transporter genes in sporadic beriberi

2014

Abstract Objective Thiamine or vitamin B 1 deficiency diminishes thiamine-dependent enzymatic activity, alters mitochondrial function, impairs oxidative metabolism, and causes selective neuronal death. We analyzed for the first time, the role of all known mutations within three specific thiamine carrier genes, SLC19 A2, SLC19 A3 , and SLC25 A19 , in a patient with atrophic beriberi, a multiorgan nutritional disease caused by thiamine deficiency. Methods A 44-year-old male alcoholic patient from Morocco developed massive bilateral leg edema, a subacute sensorimotor neuropathy, and incontinence. Despite normal vitamin B 1 serum levels, his clinical picture was rapidly reverted by high-dose in…

AdultMalemedicine.medical_specialtySLC19 A- SLC25 A19SLC19 AEndocrinology Diabetes and MetabolismGene mutationBeriberimedicine.disease_causeMitochondrial Membrane Transport Proteinslaw.inventionBeriberilawInternal medicineGenotypemedicineThiamine transporterObjective: Thiamine or vitamin B1 deficiency diminishes thiamine-dependent enzymatic activity alters mitochondrial function impairs oxidative metabolism and causes selective neuronal death. We analyzed for the first time the role of all known mutations within three specific thiamine carrier genes SLC19 A2 SLC19 A3 and SLC25 A19 in a patient with atrophic beriberi a multiorgan nutritional disease caused by thiamine deficiency. Methods: A 44-year-old male alcoholic patient from Morocco developed massive bilateral leg edema a subacute sensorimotor neuropathy and incontinence. Despite normal vitamin B1 serum levels his clinical picture was rapidly reverted by high-dose intramuscular thiamine treatment suggesting a possible genetic resistance. We used polymerase chain reaction followed by amplicon sequencing to study all the known thiamine-related gene mutations identified within the Human Gene Mutation Database. Results: Thirty-seven mutations were tested: 29 in SLC19 A2 6 in SLC19 A3 and 2 in SLC25 A19. Mutational analyses showed a wild-type genotype for all sequences investigated. Conclusion: This is the first genetic study in beriberi disease. We did not detect any known mutation in any of the three genes in a sporadic dry beriberi patient. We cannot exclude a role for other known or unknown mutations in the same genes or in other thiamine-associated genes in the occurrence of this nutritional neuropathy.HumansThiamineGenePolymerase chain reactionGeneticsMutationNutrition and DieteticsbiologyMembrane Transport ProteinsThiamine Deficiencymedicine.diseaseAlcoholismEndocrinologyMutationbiology.proteinThiamineMutations
researchProduct

Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy.

2014

In surface and interstitial high-dose-rate brachytherapy with either (60)Co, (192)Ir, or (169)Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields…

HDR brachytherapyMaterials sciencesuperficial and interstitialmedicine.medical_treatmentBrachytherapyBrachytherapydosimetric perturbationModels BiologicalSensitivity and SpecificityImaging phantomLead shieldingOpticsRadiation ProtectionShieldBody surfacemedicineHumansScattering RadiationComputer SimulationRadiometryWaste Management and DisposalMonte Carlo simulationbusiness.industrytransmissionPublic Health Environmental and Occupational HealthAbsorption RadiationReproducibility of ResultsRadiotherapy DosageGeneral MedicineEquipment DesignHigh-Dose Rate BrachytherapyEquipment Failure AnalysisLeadElectromagnetic shieldinglead shieldbusinessNuclear medicineBolus (radiation therapy)Journal of radiological protection : official journal of the Society for Radiological Protection
researchProduct

Therapeutic sequences in patients with grade 1−2 neuroendocrine tumors (NET): an observational multicenter study from the ELIOS group

2019

Purpose: Many different treatments are suggested by guidelines to treat grade 1−2 (G1−G2) neuroendocrine tumors (NET). However, a precise therapeutic algorithm has not yet been established. This study aims at identifying and comparing the main therapeutic sequences in G1−G2 NET. Methods: A retrospective observational Italian multicenter study was designed to collect data on therapeutic sequences in NET. Median progression-free survival (PFS) was compared between therapeutic sequences, as well as the number and grade of side effects and the rate of dose reduction/treatment discontinuation. Results: Among 1182 patients with neuroendocrine neoplasia included in the ELIOS database, 131 G1–G2 ga…

MaleOncologymedicine.medical_specialtyHigh-dose somatostatin analogs; neuroendocrine tumors; PRRT; sequence of treatments; somatostatin analogues; targeted therapyLung NeoplasmsDatabases FactualSettore MED/06 - Oncologia MedicaEndocrinology Diabetes and Metabolismmedicine.medical_treatmentAntineoplastic AgentsHigh-dose somatostatin analogNeuroendocrine tumorsOctreotideSomatostatin analogueTargeted therapySettore MED/13 - EndocrinologiaTargeted therapyEndocrinologyNeuroendocrine tumorStomach NeoplasmsInternal medicineDiabetes mellitusIntestinal NeoplasmsSequence of treatmentmedicineHumansEverolimusRetrospective StudiesChemotherapyEverolimusbusiness.industryDisease ManagementMiddle Agedmedicine.diseaseDiscontinuationPancreatic NeoplasmsNeuroendocrine TumorsRadionuclide therapyFemaleObservational studyPRRTSomatostatinbusinessmedicine.drug
researchProduct

High-dose-rate brachytherapy boost for prostate cancer: Analysis of dose-volume histogram parameters for predicting late, rectal toxicity

2017

PURPOSE: To determine the significance of dose-volume histogram parameters for predicting late rectal toxicity (LRT) after single-fraction high-dose-rate brachytherapy (HDRBT) boost and external beam radiotherapy (EBRT) in prostate cancer. MATERIALS AND METHODS: Three hundred patients with intermediate- or high-risk prostate cancer were included between August 2010 and March 2015. Treatment comprised a single-fraction HDRBT boost of 15.0 Gy plus EBRT (46.0 Gy delivered in 23 fractions) or an HDRBT boost of 9.5 Gy plus EBRT (60.0 Gy delivered in 30 fractions) if the seminal vesicles were infiltrated using real-time transrectal ultrasound-based planning. LRT was evaluated every 3 months after…

MaleOrgans at RiskDose-volume histogramTime Factorsmedicine.medical_treatmentBrachytherapyBrachytherapyRectumLate rectal toxicity030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancerOrgan at risk0302 clinical medicinemedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesExternal beam radiotherapyRadiation InjuriesAgedAged 80 and overProstate cancerbusiness.industryRadiotherapy Planning Computer-AssistedBiologically equivalent doseRectumProstatic NeoplasmsCommon Terminology Criteria for Adverse EventsMiddle Agedmedicine.diseaseCombined Modality TherapyHigh-Dose Rate BrachytherapyHigh-dose-rate brachytherapy boostRadiation therapyDose-volume histogram parametermedicine.anatomical_structureOncology030220 oncology & carcinogenesisRegression AnalysisDose Fractionation RadiationNuclear medicinebusinessFollow-Up Studies
researchProduct

Interobserver variability in rectum contouring in high-dose-rate brachytherapy for prostate cancer: A multi-institutional prospective analysis

2017

PURPOSE: The aim of this study was to evaluate the interobserver variability (KW) of rectum contouring, and its dosimetric consequences, for high-dose-rate brachytherapy in patients with prostate cancer across multiple institutions. METHODS AND MATERIALS: Five radiation oncologists contoured rectums in 10 patients on transperineal ultrasound image sets after establishing a delineation consensus. The D-0.1cc, D-1cc, and D-2cc rectum volume parameters were determined. The mean, standard deviation, and range of each dose-volume histogram parameter were evaluated for each patient. The JOY was determined using the coefficient of variation, and the dosimetric impacts on the total dose were analyz…

MaleOrgans at Riskmedicine.medical_specialtyCoefficient of variationmedicine.medical_treatmentBrachytherapyBrachytherapyRectumRadiation DosageStandard deviationEndosonography030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancer0302 clinical medicineHumansMedicineRadiology Nuclear Medicine and imagingProspective StudiesObserver VariationContouringProstate cancerbusiness.industryEquivalent doseRadiotherapy Planning Computer-AssistedRectumProstatic NeoplasmsRadiotherapy DosageOrgan Sizemedicine.diseaseHigh-Dose Rate Brachytherapymedicine.anatomical_structureOncologyContouringHigh-dose-rate brachytherapy030220 oncology & carcinogenesisRadiologyInterobserver variabilitybusinessNuclear medicineBrachytherapy
researchProduct

Is high dose rate brachytherapy reliable and effective treatment for prostate cancer patients? A review of the literature.

2014

The intrinsic physical and radiobiological characteristics of High Dose Rate Brachytherapy (HDR-BT) are well suited to the treatment of prostate cancer. HDR-BT was initially used as a boost to external beam brachytherapy, but has subsequently been employed as the sole treatment, which is termed HDR monotherapy. This review summarizes the clinical outcomes and toxicity results of the principal studies and discusses the radiobiological basis supporting its use.

Malemedicine.medical_specialtymedicine.medical_treatmentBrachytherapyBrachytherapyProstate cancermedicineEffective treatmentHumansMedical physicsDose FractionationSalvage brachytherapySalvage TherapyProstate cancerbusiness.industryRadiobiologyProstatic NeoplasmsRadiotherapy DosageHDR-BTHematologymedicine.diseaseBrachytherapy boost; HDR-BT; High-dose rate brachytherapy; Prostate cancer; Radiobiology; Salvage brachytherapy; Dose Fractionation; Humans; Male; Prostatic Neoplasms; Salvage Therapy; Treatment Outcome; Brachytherapy; Radiotherapy Dosage; Hematology; Oncology; Geriatrics and GerontologyHigh-Dose Rate BrachytherapyBrachytherapy boostTreatment OutcomeOncologyRadiologyDose Fractionation RadiationGeriatrics and GerontologybusinessHigh-dose rate brachytherapySalvage brachytherapyCritical reviews in oncology/hematology
researchProduct

Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

2014

Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a …

Materials scienceDose calculationbusiness.industrymedicine.medical_treatmentBrachytherapyAnalytical chemistryGeneral MedicineRadiationHigh-Dose Rate BrachytherapyFormalism (philosophy of mathematics)medicineDosimetryCobalt-60Dose rateNuclear medicinebusinessMedical Physics
researchProduct

Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions

2016

Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a 192Ir source; (ii) to calculate by means of the Monte Carlo(MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The penelope2008MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution arou…

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomHigh-Dose Rate Brachytherapy030218 nuclear medicine & medical imagingPercentage depth dose curve03 medical and health sciencesKerma0302 clinical medicine030220 oncology & carcinogenesisIonization chambermedicineDosimetryNuclear medicinebusinessMedical Physics
researchProduct