Search results for "High-Dose"

showing 5 items of 25 documents

WE-C-108-08: Organ Doses in a Male Phantom Undergoing High-Dose-Rate Brachytherapy Applied to the Prostate

2013

Purpose: The aim of this study was to obtain equivalent doses to radiosensitive organs when applying high‐dose‐rate (HDR) brachytherapy to the prostate using60 Co or 192 Ir sources, and in comparison to external‐beam radiotherapy (EBRT) modalities. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized adult reference man described in Publication 110 by the International Commission on Radiological Protection (ICRP). Point sources of 60Co or 192Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate. Equivalent doses per therapeutic absorbed dose to the prostate were obtained in several radiosensitive organs. …

business.industrymedicine.medical_treatmentBrachytherapyGeneral MedicineImaging phantomHigh-Dose Rate BrachytherapyRadiation therapymedicine.anatomical_structureProstateAbsorbed dosemedicineDosimetrybusinessNuclear medicineProton therapyMedical Physics
researchProduct

Technical note: Dosimetric study of a new Co-60 source used in brachytherapy

2007

The purpose of this study is to obtain the dosimetric parameters of a new Co-60 source used in high dose rate brachytherapy and manufactured by BEBIG (Eckert & Ziegler BEBIG GmbH, Germany). The Monte Carlo method has been used to obtain the dose rate distribution in the updated TG-43U1 formalism of the American Association of Physicists in Medicine. In addition, to aid the quality control process on treatment planning systems (TPS), a two-dimensional rectangular dose rate table, coherent with the TG-43U1 dose calculation formalism, is given. These dosimetric data sets can be used as input data of the TPS calculations and to validate them.

medicine.medical_specialtyComputer scienceNuclear engineeringmedicine.medical_treatmentMonte Carlo methodBrachytherapyImage registrationGeneral MedicineHigh-Dose Rate BrachytherapyMedical imagingmedicineDosimetryMedical physicsDose rateRadiation treatment planningMedical Physics
researchProduct

SU-FF-T-41: Monte Carlo Dosimetric Study of the New BEBIG Co-60 HDR Source

2005

Purpose: The use of high dose rate brachytherapy (HDR) is a highly extended practice today, being the Ir‐192 the most widely extended isotope used for this type of practice although Co‐60 is also available for HDR. The purpose of this study is to obtain the dosimetric parameters of the Co‐60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there is no dosimetric data available in the literature. It is recommended that accurate dose distribution data, based on a realistic geometry and on the mechanical characteristics of the source, should be obtained by an appropriate method, experimental or Monte Carlo, to be used as input in the HDR Treatment Plannin…

medicine.medical_specialtyComputer sciencemedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineDose distributionHigh-Dose Rate BrachytherapyMonte carlo codemedicineDosimetryMedical physicsDose rateAlgorithmMedical Physics
researchProduct

Die kombinierte operative und radiotherapeutische Behandlung (CORT) von Beckenwandrezidiven: Erfahrungsbericht nach 3 Jahren

1993

CORT has been developed to treat recurrent gynaecological malignancies infiltrating the pelvic wall unilaterally. The surgical part consists of: (i) staging laparotomy/lymphadenectomy, (ii) maximum tumour resection at the pelvic wall and exenteration of infiltrated central pelvic organs, (iii) implantation of guiding tubes on the residual tumour/tumour bed on the pelvic wall, (iv) pelvic wall plasty with muscle, musculocutaneous and omentum flaps, (v) operative reconstruction of bowel, bladder and perineo-vulvo-vaginal functions. Radiation is performed as interstitial high dose rate brachytherapy through the implanted tubes. Patients without prior pelvic irradiation receive in addition, who…

medicine.medical_specialtyPelvic exenterationEpitheliomabusiness.industrymedicine.medical_treatmentObstetrics and GynecologyWhole-Pelvismedicine.diseaseHigh-Dose Rate BrachytherapySurgeryRadiation therapyMaternity and MidwiferymedicineCarcinomaLymphadenectomybusinessComplicationGeburtshilfe und Frauenheilkunde
researchProduct

Immunogenicity and safety of a quadrivalent high-dose inactivated influenza vaccine compared with a standard-dose quadrivalent influenza vaccine in h…

2021

A quadrivalent high-dose inactivated influenza vaccine (IIV4-HD) is licensed for adults ≥65 y of age based on immunogenicity and efficacy studies. However, IIV4-HD has not been evaluated in adults aged 60–64 y. This study compared immunogenicity and safety of IIV4-HD with a standard-dose quadrivalent influenza vaccine (IIV4-SD) in adults aged ≥60 y. This Phase III, randomized, modified double-blind, active-controlled study enrolled 1,528 participants aged ≥60 y, randomized 1:1 to a single injection of IIV4-HD or IIV4-SD. Hemagglutination inhibition (HAI) geometric mean titers (GMTs) were measured at baseline and D 28 and seroconversion assessed. Safety was described for 180 d after vaccinat…

safetyAdultIMPACTInfluenza vaccineImmunologyimmunogenicityAntibodies ViralQuadrivalent Influenza Vaccineolder adultImmunogenicity VaccineDouble-Blind MethodInfluenza HumanMedicine and Health SciencesImmunology and AllergyMedicineHumansVaccines Combinedolder adultsPharmacologybusiness.industryImmunogenicityADULTSHemagglutination Inhibition TestsEFFICACYVirologyinfluenza vaccinationHigh-dose influenza vaccineVaccines InactivatedInfluenza VaccinesPhase III trialbusinessHuman vaccinesimmunotherapeutics
researchProduct