Search results for "High-dose rate brachytherapy"

showing 3 items of 13 documents

Technical note: Dosimetric study of a new Co-60 source used in brachytherapy

2007

The purpose of this study is to obtain the dosimetric parameters of a new Co-60 source used in high dose rate brachytherapy and manufactured by BEBIG (Eckert & Ziegler BEBIG GmbH, Germany). The Monte Carlo method has been used to obtain the dose rate distribution in the updated TG-43U1 formalism of the American Association of Physicists in Medicine. In addition, to aid the quality control process on treatment planning systems (TPS), a two-dimensional rectangular dose rate table, coherent with the TG-43U1 dose calculation formalism, is given. These dosimetric data sets can be used as input data of the TPS calculations and to validate them.

medicine.medical_specialtyComputer scienceNuclear engineeringmedicine.medical_treatmentMonte Carlo methodBrachytherapyImage registrationGeneral MedicineHigh-Dose Rate BrachytherapyMedical imagingmedicineDosimetryMedical physicsDose rateRadiation treatment planningMedical Physics
researchProduct

SU-FF-T-41: Monte Carlo Dosimetric Study of the New BEBIG Co-60 HDR Source

2005

Purpose: The use of high dose rate brachytherapy (HDR) is a highly extended practice today, being the Ir‐192 the most widely extended isotope used for this type of practice although Co‐60 is also available for HDR. The purpose of this study is to obtain the dosimetric parameters of the Co‐60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there is no dosimetric data available in the literature. It is recommended that accurate dose distribution data, based on a realistic geometry and on the mechanical characteristics of the source, should be obtained by an appropriate method, experimental or Monte Carlo, to be used as input in the HDR Treatment Plannin…

medicine.medical_specialtyComputer sciencemedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineDose distributionHigh-Dose Rate BrachytherapyMonte carlo codemedicineDosimetryMedical physicsDose rateAlgorithmMedical Physics
researchProduct

Die kombinierte operative und radiotherapeutische Behandlung (CORT) von Beckenwandrezidiven: Erfahrungsbericht nach 3 Jahren

1993

CORT has been developed to treat recurrent gynaecological malignancies infiltrating the pelvic wall unilaterally. The surgical part consists of: (i) staging laparotomy/lymphadenectomy, (ii) maximum tumour resection at the pelvic wall and exenteration of infiltrated central pelvic organs, (iii) implantation of guiding tubes on the residual tumour/tumour bed on the pelvic wall, (iv) pelvic wall plasty with muscle, musculocutaneous and omentum flaps, (v) operative reconstruction of bowel, bladder and perineo-vulvo-vaginal functions. Radiation is performed as interstitial high dose rate brachytherapy through the implanted tubes. Patients without prior pelvic irradiation receive in addition, who…

medicine.medical_specialtyPelvic exenterationEpitheliomabusiness.industrymedicine.medical_treatmentObstetrics and GynecologyWhole-Pelvismedicine.diseaseHigh-Dose Rate BrachytherapySurgeryRadiation therapyMaternity and MidwiferymedicineCarcinomaLymphadenectomybusinessComplicationGeburtshilfe und Frauenheilkunde
researchProduct