Search results for "Hip Joint"
showing 10 items of 38 documents
Hand trajectory formation during whole body reaching movements in man.
1998
End-effector trajectory formation was studied during a reaching movement using the whole body. The movements of various parts of the body were measured with the optoelectronic ELITE system. Wrist reaching movement paths showed noticeable curvatures. The analysis of various marker onset latencies revealed that the wrist was the last to move, always after the head, knee or trunk, suggesting a subordinate role of the focal component with respect to the primary role of the equilibrium component. These results suggest that reaching wrist movements are subjected to whole-body equilibrium constraints in addition to constraints placed upon end-effector kinematics or the dynamic optimization of uppe…
Komplikationen der Redon-drainage each hüftgelenksersatzoperationen — eine analyse der ursachen
1989
Die Redon-Drainage hat die Operationsresultate entscheidend verbessert. Jedoch sind einige Komplikationen durch das Hochvakuum-System nicht zu verhindern, sie sind vielmehr sogar dadurch bedingt. Redon-Flaschen als Einwegprodukte entsprechen haufig nicht den gestellten Anforderungen. Es handelt sich nur um ein zeitweise “geschlossenes” System mit hohem Infektionsrisiko bei Flaschenwechsel. Nach Entwicklung einer vom Legen bis zum Ziehen der Drains stets geschlossenen Drainage wurden in einer prospektiven Studie nach Huftgelenksersatzoperationen verschiedene systembedingte Faktoren analysiert. Verglichen wurden die Redon-Hochvakuum-Drainage sowie ein kontinuierlich ansteigender Unterdruck bi…
Failed Total Hip Arthroplasty: Diagnostic Performance of Conventional MRI Features and Locoregional Lymphadenopathy to Identify Infected Implants.
2020
Background Very little has been published about the diagnostic performance of MRI in total hip arthroplasty (THA) infection. Purpose To determine the diagnostic performance of conventional MRI features and of new lymph nodal indices to identify infection in patients with failed THA. Study type Retrospective. Population In all, 119 patients (66 females; age 66.9 ± 12.4 years) with failed THA. Field strength/sequences Metal artifact reduction sequence (MARS) protocol including short tau inversion recovery and turbo spin-echo T1 - and T2 -weighted sequences at 1.5T. Assessment Patients underwent pelvis MRI prior to failed THA revision. MRIs were reviewed to identify periprosthetic bone destruc…
Lower limb muscle moments and power during recovery from forward loss of balance in male and female single and multiple steppers
2011
Abstract Background Studying recovery responses to loss of balance may help to explain why older adults are susceptible to falls. The purpose of the present study was to assess whether male and female older adults, that use a single or multiple step recovery strategy, differ in the proportion of lower limb strength used and power produced during the stepping phase of balance recovery. Methods Eighty-four community-dwelling older adults (47 men, 37 women) participated in the study. Isometric strength of the ankle, knee and hip joint flexors and extensors was assessed using a dynamometer. Loss of balance was induced by releasing participants from a static forward lean (4 trials at each of 3 f…
Reduced-dose computed tomography is the most accurate method to measure ceramic hip resurfacing cup version
2020
Background: A precise assessment of cup version after hip resurfacing is generally requested, especially in clinical trials or in case of complications. Aims: To identify which diagnostic imaging modality, between AP pelvis X-rays, the AP Pelvis CT Scout image and reduced-dose axial CT scan, is the most precise to assess cup version of an all-ceramic hip resurfacing implant in a first-in-human clinical trial. Methods: We retrospectively assessed the cup version of the first 20 patients who underwent an experimental all-ceramic hip resurfacing on AP pelvis X-rays (0.8 mSv of radiation), AP pelvis CT scout images (0.016 mSv) and axial CT slices performed using a reduced dose protocol (0.3 mSv…
Preserving the abductor mechanism in robotic THR: the influence of stem design and cutterpath.
2004
The tip of the greater trochanter is the attachment site for the abductor muscles of the hip joint. Its preservation in robotic and conventional THR is important for normal gait. The effect of different stem designs and robotic cutterpaths on the preservation of the trochanter tip is examined.One anatomical stem, one straight stem, and one stem specifically designed for robotic THR were implanted virtually in CT scans of osteoarthrotic hip joints using the Torch preoperative planning unit (URS-ortho). In transverse sections of the trochanter tip, dimensions of the trochanter area removed by the milling tool were recorded for each stem design and different cutterpaths (3-axis versus 5-axis m…
Test-retest reliability of 3D kinematic gait variables in hip osteoarthritis patients
2011
Import JabRef | WosArea Orthopedics; Rheumatology; International audience; Objectives: (1) to investigate the test-retest reliability of 3D gait analysis (3DGA) in hip Osteoarthritis (OA) patients; (2) to find the minimum number of gait trials needed to overcome intrinsic variability; (3) to check the accuracy of angles measured by the 3D system. Design: 23 Patients suffering from hip OA with no other major disease were recruited. We evaluated the reliability of spatio-temporal variables and body angles (lower-limb joints, trunk and pelvis angles) during two sessions of 3DGA using intra-class correlation coefficients (ICC). The minimum number of trials needed to overcome intrinsic variabili…
Biomechanical factors affecting energy cost during running utilising different slopes
2019
This study aimed to examine the characteristics of electromyography (EMG) and kinematics of the supporting leg affecting energy cost while running at incline, level, and decline slopes. Twelve male Japanese middle- and long-distance runners volunteered for this study. The subjects were asked to run at 13.5 km·h
An exploration of the differences in hip strength, gluteus medius activity, and trunk, pelvis, and lower-limb biomechanics during different functiona…
2020
ABSTRACT The purpose of the study was to explore differences in the coronal biomechanics of the trunk, pelvis, hip, and knee joints, and gluteus medius muscle activity (GMed) during walking and step down from two riser heights. Joint kinematics and kinetics from 20 healthy participants were recorded using a 10-camera Qualisys system and force plates, and GMed EMG was recorded using a Delsys Trigno system. Hip abductor strength was measured using a hand-held dynamometer. Pelvic obliquity and lateral trunk bending excursions were significantly higher in walking than in step-down tasks. Significantly greater knee adduction moments were seen during both step-down tasks compared to level walking…
Effects of loss of metatarsophalangeal joint mobility on gait in rheumatoid arthritis patients
2005
Objective. To evaluate the effects of loss of range of motion (ROM) of the metatarsophalangeal (MTP) joint on the kinematic parameters of walking in rheumatoid arthritis (RA) patients. Methods. Inclusion of RA patients with inactive disease, no synovitis of the inferior limb and reduced ROM of the MTP joints. Evaluation of the ROM of the MTP dorsal and plantar flexion, and gait analysis using a three-dimensional computerized movement analysis. Calculation of gait parameters and maximal flexion and extension of the hips and knees during walking. Analysis 1 compared the ROM of dorsal and plantar flexion in patients with or without walking pain; 2 compared the gait parameters between patients …