Search results for "Hip Joint"

showing 10 items of 38 documents

Hand trajectory formation during whole body reaching movements in man.

1998

End-effector trajectory formation was studied during a reaching movement using the whole body. The movements of various parts of the body were measured with the optoelectronic ELITE system. Wrist reaching movement paths showed noticeable curvatures. The analysis of various marker onset latencies revealed that the wrist was the last to move, always after the head, knee or trunk, suggesting a subordinate role of the focal component with respect to the primary role of the equilibrium component. These results suggest that reaching wrist movements are subjected to whole-body equilibrium constraints in addition to constraints placed upon end-effector kinematics or the dynamic optimization of uppe…

AdultWrist Jointmedicine.medical_specialtyKnee JointMovementKinematicsWristPostural controlPhysical medicine and rehabilitationmedicineHumansPostural BalanceCommunicationMovement (music)business.industryShoulder JointGeneral NeuroscienceBody movementHandTrunkKinesismedicine.anatomical_structureTrajectoryHip JointWhole bodybusinessGeologyNeuroscience letters
researchProduct

Komplikationen der Redon-drainage each hüftgelenksersatzoperationen — eine analyse der ursachen

1989

Die Redon-Drainage hat die Operationsresultate entscheidend verbessert. Jedoch sind einige Komplikationen durch das Hochvakuum-System nicht zu verhindern, sie sind vielmehr sogar dadurch bedingt. Redon-Flaschen als Einwegprodukte entsprechen haufig nicht den gestellten Anforderungen. Es handelt sich nur um ein zeitweise “geschlossenes” System mit hohem Infektionsrisiko bei Flaschenwechsel. Nach Entwicklung einer vom Legen bis zum Ziehen der Drains stets geschlossenen Drainage wurden in einer prospektiven Studie nach Huftgelenksersatzoperationen verschiedene systembedingte Faktoren analysiert. Verglichen wurden die Redon-Hochvakuum-Drainage sowie ein kontinuierlich ansteigender Unterdruck bi…

Gynecologymedicine.medical_specialtybusiness.industrymedicineSurgerybusinessHip joint replacementUnfallchirurgie
researchProduct

Failed Total Hip Arthroplasty: Diagnostic Performance of Conventional MRI Features and Locoregional Lymphadenopathy to Identify Infected Implants.

2020

Background Very little has been published about the diagnostic performance of MRI in total hip arthroplasty (THA) infection. Purpose To determine the diagnostic performance of conventional MRI features and of new lymph nodal indices to identify infection in patients with failed THA. Study type Retrospective. Population In all, 119 patients (66 females; age 66.9 ± 12.4 years) with failed THA. Field strength/sequences Metal artifact reduction sequence (MARS) protocol including short tau inversion recovery and turbo spin-echo T1 - and T2 -weighted sequences at 1.5T. Assessment Patients underwent pelvis MRI prior to failed THA revision. MRIs were reviewed to identify periprosthetic bone destruc…

Iliac Lymph Nodemedicine.medical_treatmentArthroplasty Replacement HipPopulationPeriprostheticLymphadenopathy030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineSynovitisMedicineHumansRadiology Nuclear Medicine and imagingStage (cooking)educationAgedRetrospective Studieseducation.field_of_studymedicine.diagnostic_testbusiness.industryMagnetic resonance imagingMiddle Agedmedicine.diseaseArthroplastyMagnetic Resonance ImagingEffusionFemaleHip JointbusinessNuclear medicineJournal of magnetic resonance imaging : JMRIReferences
researchProduct

Lower limb muscle moments and power during recovery from forward loss of balance in male and female single and multiple steppers

2011

Abstract Background Studying recovery responses to loss of balance may help to explain why older adults are susceptible to falls. The purpose of the present study was to assess whether male and female older adults, that use a single or multiple step recovery strategy, differ in the proportion of lower limb strength used and power produced during the stepping phase of balance recovery. Methods Eighty-four community-dwelling older adults (47 men, 37 women) participated in the study. Isometric strength of the ankle, knee and hip joint flexors and extensors was assessed using a dynamometer. Loss of balance was induced by releasing participants from a static forward lean (4 trials at each of 3 f…

MaleAgingMuscle Strength Dynamometermedicine.medical_specialtyKnee JointBiophysicsPoison controlSingle stepMuscle Strength DynamometerIsometric exerciseSex FactorsLower limb muscleRisk FactorsHumansMedicineOrthopedics and Sports MedicineMuscle StrengthPostural BalanceAgedBalance (ability)Aged 80 and overMuscle Weaknessbusiness.industryBiomechanicsmedicine.anatomical_structureLower ExtremityPhysical therapyAccidental FallsFemaleHip JointAnklebusinessAnkle JointClinical Biomechanics
researchProduct

Reduced-dose computed tomography is the most accurate method to measure ceramic hip resurfacing cup version

2020

Background: A precise assessment of cup version after hip resurfacing is generally requested, especially in clinical trials or in case of complications. Aims: To identify which diagnostic imaging modality, between AP pelvis X-rays, the AP Pelvis CT Scout image and reduced-dose axial CT scan, is the most precise to assess cup version of an all-ceramic hip resurfacing implant in a first-in-human clinical trial. Methods: We retrospectively assessed the cup version of the first 20 patients who underwent an experimental all-ceramic hip resurfacing on AP pelvis X-rays (0.8 mSv of radiation), AP pelvis CT scout images (0.016 mSv) and axial CT slices performed using a reduced dose protocol (0.3 mSv…

MaleCeramicsArthroplasty Replacement Hipmedicine.medical_treatmentReproducibility of ResultComputed tomographyCT scout viewRadiation DosageHip joint replacement030218 nuclear medicine & medical imaging03 medical and health sciencesCT/low dose0302 clinical medicineRetrospective StudieMedical imagingmedicineX-rays/radiographsHumansHip ProsthesiRadiology Nuclear Medicine and imagingPelvisRetrospective Studiesmedicine.diagnostic_testX-rays/radiographbusiness.industryReproducibility of ResultsGeneral MedicineMiddle AgedHip joint/cup versionCeramicReduced doseHip resurfacingHip joint/replacementRadiation exposureTomography x ray computedmedicine.anatomical_structure030220 oncology & carcinogenesisFemaleHip JointHip ProsthesisHip joint/resurfacingTomography X-Ray ComputedNuclear medicinebusinessHuman
researchProduct

Preserving the abductor mechanism in robotic THR: the influence of stem design and cutterpath.

2004

The tip of the greater trochanter is the attachment site for the abductor muscles of the hip joint. Its preservation in robotic and conventional THR is important for normal gait. The effect of different stem designs and robotic cutterpaths on the preservation of the trochanter tip is examined.One anatomical stem, one straight stem, and one stem specifically designed for robotic THR were implanted virtually in CT scans of osteoarthrotic hip joints using the Torch preoperative planning unit (URS-ortho). In transverse sections of the trochanter tip, dimensions of the trochanter area removed by the milling tool were recorded for each stem design and different cutterpaths (3-axis versus 5-axis m…

MaleGreater trochanterMaterials scienceAttachment siteArthroplasty Replacement HipUser-Computer InterfaceProsthesis FittingOsteoarthritismedicineHumansFemurMuscle SkeletalGaitPreoperative planningTrochantertechnology industry and agricultureStraight stemAnatomyRoboticsComputer Science ApplicationsMechanism (engineering)Normal gaitmedicine.anatomical_structureSurgery Computer-AssistedSurgeryMuscles of the hipFemaleHip JointFamily PracticeTomography X-Ray ComputedBiomedical engineeringComputer aided surgery : official journal of the International Society for Computer Aided Surgery
researchProduct

Test-retest reliability of 3D kinematic gait variables in hip osteoarthritis patients

2011

Import JabRef | WosArea Orthopedics; Rheumatology; International audience; Objectives: (1) to investigate the test-retest reliability of 3D gait analysis (3DGA) in hip Osteoarthritis (OA) patients; (2) to find the minimum number of gait trials needed to overcome intrinsic variability; (3) to check the accuracy of angles measured by the 3D system. Design: 23 Patients suffering from hip OA with no other major disease were recruited. We evaluated the reliability of spatio-temporal variables and body angles (lower-limb joints, trunk and pelvis angles) during two sessions of 3DGA using intra-class correlation coefficients (ICC). The minimum number of trials needed to overcome intrinsic variabili…

MaleKinematicsKnee JointMOTOR PATTERNSKinematicsOsteoarthritis Hip0302 clinical medicineGait (human)HUMAN LOCOMOTIONOrthopedics and Sports MedicineGaitReliability (statistics)MathematicsOrthodonticsJOINTRepeatabilityMiddle AgedReliabilityBiomechanical Phenomenamedicine.anatomical_structureGoniometer[ SCCO.NEUR ] Cognitive science/NeuroscienceFemaleHip JointWALKINGmedicine.medical_specialtyBiomedical EngineeringKNEE OSTEOARTHRITISValidity03 medical and health sciencesImaging Three-DimensionalRheumatologyOsteoarthritismedicineHumansARTHROPLASTYMOTION ANALYSIS SYSTEMPelvisAgedHip[SCCO.NEUR]Cognitive science/NeuroscienceOUTCOME MEASUREReproducibility of ResultsRHEUMATOID-ARTHRITIS PATIENTS030229 sport sciencesTrunk3D gait analysisKineticsGait analysisPhysical therapyINTRA-RATER030217 neurology & neurosurgeryAnkle Joint
researchProduct

Biomechanical factors affecting energy cost during running utilising different slopes

2019

This study aimed to examine the characteristics of electromyography (EMG) and kinematics of the supporting leg affecting energy cost while running at incline, level, and decline slopes. Twelve male Japanese middle- and long-distance runners volunteered for this study. The subjects were asked to run at 13.5 km·h

MaleKnee JointComputer scienceMovement030209 endocrinology & metabolismPhysical Therapy Sports Therapy and RehabilitationKinematicsElectromyographyAutomotive engineeringRunningYoung Adult03 medical and health sciences0302 clinical medicinemedicineHumansOrthopedics and Sports MedicineMuscle Skeletalmedicine.diagnostic_testElectromyographyPulmonary Gas Exchange030229 sport sciencesBiomechanical Phenomenabody regionsLower ExtremityExercise TestRunning economyEnergy costHip JointEnergy MetabolismAnkle JointJournal of Sports Sciences
researchProduct

An exploration of the differences in hip strength, gluteus medius activity, and trunk, pelvis, and lower-limb biomechanics during different functiona…

2020

ABSTRACT The purpose of the study was to explore differences in the coronal biomechanics of the trunk, pelvis, hip, and knee joints, and gluteus medius muscle activity (GMed) during walking and step down from two riser heights. Joint kinematics and kinetics from 20 healthy participants were recorded using a 10-camera Qualisys system and force plates, and GMed EMG was recorded using a Delsys Trigno system. Hip abductor strength was measured using a hand-held dynamometer. Pelvic obliquity and lateral trunk bending excursions were significantly higher in walking than in step-down tasks. Significantly greater knee adduction moments were seen during both step-down tasks compared to level walking…

MaleKnee JointPhysiologyKinematicsWalkingAbdomenQP1-981Orthopedics and Sports MedicineGaitGluteus medius musclemuscle activitybiologyRehabilitationBiomechanicsTorsoPelvic dropHealthy VolunteersComputer Science ApplicationsBiomechanical PhenomenaMediusmedicine.anatomical_structureThighFemaleHip JointBiotechnologyResearch ArticleAdultmedicine.medical_specialtyBiomedical EngineeringPhysical Therapy Sports Therapy and RehabilitationMuscle Strength DynamometerPelvisPhysical medicine and rehabilitationstep downmedicineHumansForce platformMuscle StrengthMuscle SkeletalPelvisbusiness.industryElectromyographybiology.organism_classificationC600Trunkjoint momentCoronal planelateral trunk bendingButtocksbusinessTP248.13-248.65International biomechanics
researchProduct

Effects of loss of metatarsophalangeal joint mobility on gait in rheumatoid arthritis patients

2005

Objective. To evaluate the effects of loss of range of motion (ROM) of the metatarsophalangeal (MTP) joint on the kinematic parameters of walking in rheumatoid arthritis (RA) patients. Methods. Inclusion of RA patients with inactive disease, no synovitis of the inferior limb and reduced ROM of the MTP joints. Evaluation of the ROM of the MTP dorsal and plantar flexion, and gait analysis using a three-dimensional computerized movement analysis. Calculation of gait parameters and maximal flexion and extension of the hips and knees during walking. Analysis 1 compared the ROM of dorsal and plantar flexion in patients with or without walking pain; 2 compared the gait parameters between patients …

MaleMetatarsophalangeal Jointmusculoskeletal diseasesmedicine.medical_specialtyKnee JointPainWalkingKnee JointArthritis RheumatoidPhysical medicine and rehabilitationRheumatologyInternal medicineSynovitisHumansMedicinePharmacology (medical)Range of Motion ArticularGaitAgedbusiness.industryForefootForefoot HumanMiddle Agedmusculoskeletal systemmedicine.diseaseGaitRheumatologyBiomechanical Phenomenabody regionsPreferred walking speedGait analysisPhysical therapyFemaleHip JointbusinessRange of motionhuman activitiesRheumatology
researchProduct