Search results for "Humerus"
showing 10 items of 50 documents
Fatal attack on a pedestrian by an escaped circus elephant
2019
Abstract We report the case of a 65-year-old man who was attacked and killed by a female elephant that had previously escaped from a nearby circus. According to a witness the man was lifted up by the tusks, flung into the air and stomped upon. At autopsy the body showed signs of severe blunt force trauma and impalement, including multiple lacerations of the skin, a crushed thorax, a spinal fracture and a fractured humerus. The spinal cord and the major abdominal vessels were severed. There have been very few elephant attacks in Europe; this is the first reported case in Germany.
Humeral nailing revisited.
2008
Unreamed interlocked humeral nailing for stabilisation of acute humeral fractures was introduced a decade ago. Antegrade and retrograde nail insertion are equally popular. The role of nailing as opposed to plating of humeral fractures is the subject of continuous debate. Between 1997 and 2005, 99 acute fractures of the humeral shaft were treated operatively with the unreamed humeral nail (UHN, Synthes) in our Level I Trauma Centre. The mean age of the patients was 63 years. Only eight patients (8.1%) were polytraumatised, nine patients had an open fracture (9.1%), five had a primary radial nerve palsy (5.1%). There were 54 antegrade and 45 retrograde nailings. The procedures were performed …
Orthopedic versus surgical treatment of Gartland type II supracondylar humerus fracture in children.
2013
The choice of orthopedic or surgical treatment for Gartland type II supracondylar humeral fractures remains controversial. The aim of this study was to retrospectively compare the outcomes in orthopedic and surgical treatment in type II supracondylar humeral fractures in children treated in the Orthopedic and Traumatology Children Unit of our tertiary hospital over the period between 2007 and 2010. This study suggests that orthopedic treatment is a valid option for the treatment of this type of fractures, with radiological and functional results as good as those obtained with surgical treatment, avoiding surgical complications and decreasing the hospital stay.
The incidence of hip, forearm, humeral, ankle, and vertebral fragility fractures in Italy: results from a 3-year multicenter study
2010
Introduction: We aimed to assess the incidence and hospitalization rate of hip and "minor" fragility fractures in the Italian population.Methods: We carried out a 3-year survey at 10 major Italian emergency departments to evaluate the hospitalization rate of hip, forearm, humeral, ankle, and vertebral fragility fractures in people 45 years or older between 2004 and 2006, both men and women. These data were compared with those recorded in the national hospitalizations database (SDO) to assess the overall incidence of fragility fractures occurring at hip and other sites, including also those events not resulting in hospital admissions.Results: We observed 29,017 fractures across 3 years, with…
Blood circulation of long bones in trained growing rats and mice
1975
The effect of physical training on the blood circulation of long bones was studied in growing rats and mice of NMRI-strain. The animals to be trained and their controls were about 2 weeks old at the beginning of the training. The training took place on a 5 degree inclined treadmill 5 days a week for 3 weeks in experiment I and 7 weeks in experiments II and III. The duration of the daily exercise was progressively increased over 3 weeks. The final exercise bouts were 80 min for moderate and 180 min for intensive training programs. The circulating red cell volume (ml/100 g bone) of the humeral, femoral and tibial bones of the trained animals was lower compared to the controls in all three exp…
Modular megaprosthesis reconstruction for oncological and non-oncological resection of the elbow joint
2016
Abstract Background Reconstruction of large bone defects around the elbow joint is surgically demanding due to sparse soft tissue coverage, complex biomechanics and the close proximity to neurovascular structures. Modular megaprostheses are established reconstruction tools for the elbow, but only small case series have been reported in the literature. Methods Thirty-six patients who underwent reconstruction of the elbow joint with a modular megaprosthesis were reviewed retrospectively. In 31 patients (86.1%), elbow replacement was performed after resection of a bone tumour, whereas five non-oncological patients (13.9%) underwent surgery because of a previous failed elbow reconstruction. Fun…
Bloqueo interescalénico guiado por ecografía en un paciente con alteraciones anatómicas de la región supraclavicular secundarias a radioterapia y cir…
2011
Regional blocks can be difficult in surgical patients with certain superficial anatomical abnormalities. Such blocks may be possible, however, under ultrasound guidance. We report a case in which a man with a fractured right humerus required an ultrasound-guided interscalene brachial plexus block. Secondary to radiotherapy, the patient had right cervical and facial abnormalities that had altered the location of external anatomical landmarks. We describe the approach used to insert the catheter and the exploration of the region by ultrasound. Nerve stimulation was not used to avoid painful contractions. Analgesia was excellent during surgery and over the following 24 hours.
Sind winkelstabile Plattensysteme mit elastischen Eigenschaften für die Stabilisierung der Oberarmkopffraktur vorteilhaft? / Eine in-vitro biomechani…
2004
AbstractWinkelstabile Platten werden mit zunehmender Häufigkeit zur Stabilisierung von Oberarmkopfbrüchen verwendet. Rigide Implantate führen bei osteoporotischen Knochenverhältnissen u. U. aber häufiger zum Versagen. Um den Effekt der Implantatelastizität zu beurteilen wurden in einer in-vitro Studie die biomechanischen Eigenschaften eines rigiden und eines elastischen winkelstabilen Plattensystems vergleichend analysiert. An 8 Humeruspaaren wurde eine instabile subkapitale Fraktur simuliert. Die Proben wurden axial- und torsions-belastet. Analysiert wurden die Steifigkeit, das Setzverhalten unter Dauerlast und die Versagensbelastung.Das elastische Plattensystem kennzeichnete sich durch ei…
Osteosynthese am proximalen Humerus mittels winkelstabiler Platte oder Doppelplatte: eine vergleichende biomechanische Untersuchung / Angle-fixed pla…
2008
Internal fixation of fractures of the proximal humerus needs a high stability of fixation to avoid secondary loss of fixation. This is especially important in osteoporotic bone. In an experimental study, the biomechanical properties of the angle-fixed Philos plate (internal fixator) and a double-plate osteosynthesis using two one-third tubular plates were assessed. The fracture model was an unstable three-part fracture (AO type B2). Eight pairs of human cadaveric humeri were submitted to axial load and torque. In the first part of the study, it was assessed to which degree the original stiffness of the humeri could be restored after the osteotomy by the osteosynthesis procedure. Subsequentl…
Numerical study of the components positioning influence on the stability of a reverse shoulder prosthesis
2014
Aim of this paper is to setup a novel procedure able to analyze performances of a reverse shoulder prosthesis when different geometrical configurations are assumed. Nowadays, such a prosthesis is widely used but, because of its novelty, data in literature give poor information about performances and limits to its applicability. The activity has been divided into the following steps. At the beginning the shape of the prosthesis has been digitally acquired via a 3D scanner. Then, CAD models of all prosthetic components have been geometrically optimized in a way to obtain final entities suitable for numerical simulations. After that, CAD assemblies have been created between prosthetic componen…