Search results for "Hyperopia"

showing 10 items of 30 documents

Sensibilidad al contraste tras cirugía de cristalino transparente con lente intraocular multifocal asférica difractiva

2013

PURPOSE: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model) intraocular lens (IOL). METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively) were measured before and 6 months postoperatively. Monocular CS function was measured at t…

HiperopiaHyperopiaPhacoemulsificationVisual acuityMiopíaLens implantation intraocularImplantación de lentes intraocularesMyopiaAgudeza visualLens cristallineCristalinoFacoemulsificación
researchProduct

Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.

2008

Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …

Laser surgeryMalemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituAcrylic ResinsVisual AcuityKeratomileusisIntraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineMyopiaHumansProspective StudiesDioptreAgedLenses Intraocularmedicine.diagnostic_testbusiness.industryCorneal TopographyMultifocal intraocular lensMiddle AgedCorneal topographymedicine.diseasePrognosiseye diseasesOphthalmologyHyperopiaFemaleLasers Excimersense organsmedicine.symptombusinessFollow-Up StudiesAmerican journal of ophthalmology
researchProduct

Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens

2009

Our purpose was to assess the visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL; Carl Zeiss Meditec, Jena, Germany) in patients with hyperopia. We did a prospective and nonrandomized study. One hundred and seventy eyes of 85 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low to moderate hyperopia (IOL power, 21 to 24.5 diopters [D]) and high hyperopia (IOL power, 25 to 36 D). Monocular and binocular best spectacle-corrected visual acuity (BSCVA), best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (VA), and distance contrast sensitivity …

MaleRefractive errormedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensContrast SensitivityVision disorderTonometry OcularLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesIntraocular PressureDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryHipermetropíaPresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOftalmologíaOptometryFemalesense organsmedicine.symptombusinessPhotopic visionAmerican Journal of Ophthalmology
researchProduct

Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

2012

PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients ha…

MaleVisual acuitygenetic structuresDesenho de prótesesmedicine.medical_treatmentVisual AcuityEmmetropiaIntraocular lensProsthesis designMyopia/surgerylaw.inventionNear visionLens Implantation Intraocularlcsh:OphthalmologylawTonometry ocularMyopiaProspective StudiesLenses IntraocularLens crystalline/surgeryAcuidade visualGeneral MedicineMiddle AgedLens (optics)HyperopiaTreatment OutcomeFemalemedicine.symptomLens crystallinemedicine.medical_specialtyVisual acuityMiopiaRefractive lens exchangeProsthesis DesignStatistics NonparametricOphthalmologyLens CrystallinemedicineHumansHyperopia/physiopathologyHipermetropiaCristalinoAgedPhacoemulsificationbusiness.industryReproducibility of ResultsPhacoemulsificationPresbyopiamedicine.diseaseeye diseasesOphthalmologyLens implantation intraocularlcsh:RE1-994OptometryImplantação de lentes intraocularessense organsbusinessArquivos Brasileiros de Oftalmologia
researchProduct

Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

2013

Purpose: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof ReSTOR (SN6AD3 model) intraocular lens (IOL) Methods: Sixty eyes of 30 consecutive patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patients sample was divided into myopic [n=15, mean spherical equivalent (SE) -6.87± 2.03 diopters (D)] and hyperopic (n=15, mean SE +4.52±1.14 D) groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respec…

Malegenetic structuresMesopic visionmedicine.medical_treatmentVisual AcuityIntraocular lensMyopia/surgerylaw.inventionLens Implantation Intraocularlcsh:OphthalmologylawMyopiaContrast (vision)Prospective StudiesDioptreMathematicsmedia_commonLenses Intraoculareducation.field_of_studyGeneral MedicineMiddle AgedFacoemulsificaciónLens (optics)HiperopiaHyperopiaFemalePhotopic visionmedicine.medical_specialtyMiopíaVisual acuitymedia_common.quotation_subjectPopulationCataract ExtractionContrast SensitivityVision MonocularOphthalmologyImplantación de lentes intraocularesmedicineHumansHyperopia/physiopathologyAgudeza visualeducationCristalinoAgedMonocularPhacoemulsificationDistance PerceptionLens cristalline/surgeryeye diseasesOphthalmologyLens implantation intraocularlcsh:RE1-994Optometrysense organs
researchProduct

Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.

2011

PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…

Malemedicine.medical_specialtyDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeNear visual acuityFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicinePhacoemulsificationPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyHyperopiaTreatment Outcome030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation

2007

Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityEmmetropiaIntraocular lensProsthesis DesignOphthalmoscopyTonometry OcularLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularClear lens extractionPhacoemulsificationmedicine.diagnostic_testbusiness.industryPhacoemulsificationPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOptometryFemalesense organsbusinessOphthalmology
researchProduct

Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism

2017

Purpose: To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. Methods: A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period wa…

Malemedicine.medical_specialtyKeratoconusCorneal Wavefront AberrationVisual acuityCorneal ectasiagenetic structuresContact LensesVisual AcuityAstigmatismKeratoconusCornea03 medical and health sciences0302 clinical medicineProsthesis FittingOphthalmologyCorneamedicineHumansHigh orderIrregular astigmatismmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyEye Diseases HereditaryCorneoscleral contact lensGeneral MedicineMiddle Agedmedicine.diseaseCorneal topographyeye diseasesOphthalmologyHyperopiamedicine.anatomical_structureEye examination030221 ophthalmology & optometrysense organsmedicine.symptombusinessSclera030217 neurology & neurosurgeryOptometry
researchProduct

Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis

2010

To evaluate distance, intermediate, and near visual quality in eyes with diffractive intraocular lens (IOL) implantation after previous hyperopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Corrected distance visual acuity (CDVA) at 12.5%, 25.0%, and 100% contrast levels under photopic and mesopic conditions; uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, defocus curves, and corneal higher-order aberrations (HOAs) were measured in eyes that had AcrySof Restor SN60D3 spherical IOL implantation (study group) and in phakic eyes (control group) after hyperopic LASIK.Under photopic conditions at 100% contrast, …

Malemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentKeratomileusis Laser In SituMesopic VisionVisual AcuityIntraocular lensKeratomileusisRefraction OcularCohort StudiesLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesAgedPostoperative CarePhacoemulsificationColor Visionbusiness.industryLASIKPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Refractive and Visual Results after Implantation of the AcrySof ReSTOR IOL in High and Low Hyperopic Eyes

2009

To assess the differences in refractive and visual results obtained in eyes with high and low hyperopia after implantation of a multifocal intraocular lens (IOL).A prospective study was performed on 172 hyperopic eyes implanted with the AcrySof Re-STOR Natural (SN60D3) IOL. Two groups were created, high and low hyperopes (86 eyes in both cases). We analyzed monocular visual acuity for distance and near, with and without distance correction. Photopic and mesopic contrast sensitivity (CS) were also assessed. All measurements were performed at 6 months after surgery.Monocular best distance-corrected visual acuity was 0.01+/-0.03 logMAR for low hyperopes and 0.04+/-0.10 logMAR for high hyperope…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresVisual AcuityProsthesis DesignRefraction Ocular03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyHyperopia030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct