Search results for "IMPLANTATION"

showing 10 items of 733 documents

Posterior chamber phakic intraocular lenses after penetrating keratoplasty.

2009

Purpose To evaluate the efficacy, predictability, and safety of a phakic posterior chamber intraocular Collamer lens (ICL) after penetrating keratoplasty (PKP). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods A myopic or toric ICL was implanted after PKP in eyes unable to wear glasses or contact lenses and for which corneal laser surgery was contraindicated. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error, and endothelial cell count were recorded preoperatively and 24 months postoperatively. Results Preoperatively, the 15 eyes had myopia from −2.00 to −17.00 diopters (D) or astigmatism from −1.50 to −7.00 D. …

Laser surgeryAdultMaleRefractive errormedicine.medical_specialtyPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensCell CountAstigmatismPhakic intraocular lensSafety indexPostoperative ComplicationsLens Implantation IntraocularRefractive surgeryOphthalmologymedicineMyopiaHumansProspective StudiesDioptrebusiness.industryEndothelium CornealAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment OutcomeSurgeryFemalesense organsbusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.

2008

Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …

Laser surgeryMalemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituAcrylic ResinsVisual AcuityKeratomileusisIntraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineMyopiaHumansProspective StudiesDioptreAgedLenses Intraocularmedicine.diagnostic_testbusiness.industryCorneal TopographyMultifocal intraocular lensMiddle AgedCorneal topographymedicine.diseasePrognosiseye diseasesOphthalmologyHyperopiaFemaleLasers Excimersense organsmedicine.symptombusinessFollow-Up StudiesAmerican journal of ophthalmology
researchProduct

Closed foldable capsular rings

2004

A new foldable capsular tension and bending ring system with a sharp-edged design is described. The closed foldable capsular rings (CFCR) consist of 8 hydrophobic and 8 hydrophilic ring segments. The CFCRs have a 9.2 mm minimum overall diameter. The CFCRs were inserted using various cartridge systems or a two-folded technique with a forceps. The CFCRs were implanted after phacoemulsification through a small (1.6 to 3.2 mm) incision in 104 human adult eyes without intraoperative complications. No postoperative complications such as capsule folds or inward bending were observed over a 6-month follow-up. Posterior capsule opacification was minimal or absent in all eyes.

Lens capsulemedicine.medical_specialtyPhacoemulsificationMaterials sciencePolymethyl methacrylatemedicine.medical_treatmentForcepsLens Capsule CrystallineCapsuleProstheses and ImplantsPhacoemulsificationAnatomyCataractSensory SystemsProsthesis ImplantationOphthalmologyPostoperative ComplicationsOphthalmologymedicineHumansPolymethyl MethacrylateSurgeryPosterior capsule opacificationJournal of Cataract and Refractive Surgery
researchProduct

Compression forces of haptics of selected posterior chamber lenses

1997

Abstract Purpose: To compare the compressive forces of the haptics of different intraocular lens (IOL) models and analyze the observed differences. Setting: Central Hospital of Central Finland and University of Jyvaskyla, Jyvaskyla, Finland. Methods: The haptics of 28 IOL models were compressed to a diameter of 9.0 mm. The compression forces were measured at 0.5 mm intervals. The conclusions were verified by numerical simulations of mechanical models of the lenses. Results: The measured forces varied between 100 and 601 mg at a diameter of 11.0 mm, 206 and 1057 mg at a diameter of 10.0 mm, and 315 and 2094 mg at a diameter of 9.0 mm. The slopes of the force curves of the three-piece lenses …

Lenses IntraocularMaterials scienceCompressive Strengthbusiness.industryMechanical modelsmedicine.medical_treatmentIntraocular lensCompression (physics)Sensory SystemsForce curveslaw.inventionLens (optics)OphthalmologyOpticsCompressive strengthLens Implantation IntraocularlawmedicineSurgerybusinessBiomedical engineeringHaptic technologyJournal of Cataract and Refractive Surgery
researchProduct

Compression forces of haptics of freely rotating posterior chamber intraocular lenses.

1998

Abstract Purpose: To measure the compressive forces of the haptics of 28 intraocular lens (IOL) models for different modes of compression and compare the results of two types of measurements. Setting: Department of Ophthalmology, Central Hospital of Central Finland, Jyvaskyla, Finland. Methods: The haptics of 28 types of IOLs were compressed to a diameter of 9.0 mm between curved anvils. The compression forces in the plane of compression (i.e., in the plane of the optics) were measured at 0.5 mm intervals. During compression, the optics and the haptics were free to rotate with respect to the anvils. The results were compared with those of earlier measurements in which the optics were held f…

Lenses IntraocularMaterials scienceCompressive Strengthbusiness.industryPlane (geometry)medicine.medical_treatmentStiffnessIntraocular lensCompression (physics)RotationSensory Systemslaw.inventionLens (optics)OphthalmologyOpticsLens Implantation IntraocularlawmedicinePerpendicularSurgerymedicine.symptombusinessHaptic technologyJournal of cataract and refractive surgery
researchProduct

Optical Quality Comparison between Spherical and Aspheric Toric Intraocular Lenses

2014

Purpose To measure and compare the optical quality of spherical and aspheric toric intraocular lenses (IOLs). Methods Wavefront aberrations of AcrySof Toric and IQ Toric IOLs (Alcon Laboratories) for different powers were measured at 3- and 5-mm pupils by Nimo TR0805 instrument. The Zernike coefficients of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. The point spread functions (PSFs) of each IOL evaluated were calculated from the wavefront aberrations. The PSF images also were calculated from the IOL wavefront aberrations, adding the cornea's aberrations to simulate the optical quality after their implantation. Results Spherical toric IOLs showed…

Lenses IntraocularWavefrontPhysicsOptics and PhotonicsCorneal Wavefront Aberrationbusiness.industryZernike polynomialsAberrometryAstigmatismComa (optics)General MedicineModels TheoreticalOptical qualityOphthalmologyAlcon LaboratoriesSpherical aberrationsymbols.namesakeOpticsLens Implantation IntraocularIntraocular lensesAberrometrysymbolsHumansbusinessEuropean Journal of Ophthalmology
researchProduct

Incisional Keratotomy to Toric Intraocular Lenses: An Overview of the Correction of Astigmatism in Cataract and Refractive Surgery

2003

Lenses Intraocularmedicine.medical_specialtybusiness.industrymedicine.medical_treatmentAstigmatismCataract ExtractionAstigmatismmedicine.diseasePhotorefractive KeratectomyRefractive Surgical ProceduresCorneaOphthalmologyPostoperative ComplicationsLens Implantation IntraocularIntraocular lensesOphthalmologyRefractive surgerymedicineHumansLasers ExcimerbusinessKeratotomy RadialInternational Ophthalmology Clinics
researchProduct

The role of the leptin in reproduction.

2006

Since its discovery in 1994, leptin has appeared to be a pleiotrophic hormone, governing energy homeostasis and affecting many tissues in the body. Numerous pieces of evidence have accumulated showing that leptin potentially plays an important role in the control of the reproductive function.This review presents the major concepts for the role of leptin in the modulation of reproductive function. As a marker of the nutritional status, leptin affects the hypothalamo-pituitary-gonadal axis, regulating gonadotrophin-releasing hormone and luteinising hormone secretion, and appears to be a permissive factor in the onset of the puberty. This protein and its receptor have been found in the reprodu…

Leptinmedicine.medical_specialtyLeptin receptorLeptinmedia_common.quotation_subjectReproductiondigestive oral and skin physiologyOvaryObstetrics and GynecologyBiologyEnergy homeostasisEndometriumEndocrinologyPregnancyInternal medicinemedicineHumansFemaleEmbryo ImplantationReproductionhormones hormone substitutes and hormone antagonistsHormonemedia_commonCurrent opinion in obstetricsgynecology
researchProduct

Paracrine dialogue in implantation

2002

We know that the implantation process requires a functionally normal embryo at the blastocyst stage and a receptive endometrium, but also a communication link between them is needed. This paracrine dialogue between the embryo, endometrium and the corpus luteum are known to occur in ruminants and primates, more specifically endometrial-embryonic interactions have been reported in rodents and primates but not in humans. This process is a highly regulated mechanism and many molecules take part in this cross-talk. Here, we present updated information in humans on the embryonic regulation of endometrial epithelial molecules such as chemokines, adhesion and anti-adhesion molecules, and leptin dur…

Leptinmedicine.medical_specialtyReceptors Cell SurfaceBiologyEndometriumBiochemistryEndometriumParacrine signallingEndocrinologyPregnancyInternal medicineParacrine CommunicationCell AdhesionmedicineHumansEmbryo ImplantationEndotheliumBlastocystGonadal Steroid HormonesMolecular Biologyurogenital systemMechanism (biology)Mucin-1Epithelial CellsEmbryoEmbryo TransferEmbryonic stem cellCell biologyAppositionBlastocystmedicine.anatomical_structureEndocrinologyCytokinesReceptors LeptinFemaleChemokinesCarrier ProteinsCorpus luteumMolecular and Cellular Endocrinology
researchProduct

The effect of orally administered probiotic Lactobacillus reuteri -containing tablets in peri-implant mucositis: a double-blind randomized controlled…

2015

Background and Objectives Probiotics create a biofilm and protect the oral tissues against the action of periodontal pathogenic bacteria. The aim of this study was to evaluate the effects of the oral probiotic Lactobacillus reuteri Prodentis upon the peri-implant health of edentulous patients with dental implants and peri-implant mucositis, establishing comparisons vs implants without peri-implant disease. Material and Methods A double-blind, placebo-controlled, prospective cross-over study was made. The patients were all edentulous and were divided into two groups, (A) no peri-implant disease, and (B) peri-implant mucositis affecting one or more implants. Patients with peri-implantitis wer…

Limosilactobacillus reuteriMaleMucositismedicine.medical_specialtyPeri-implant mucositisDentistryPlaceboGastroenterologylaw.inventionPlacebosProbioticDouble-Blind MethodRandomized controlled triallawInternal medicinemedicineMucositisHumansProspective StudiesProspective cohort studyAgedCross-Over Studiesbiologybusiness.industryProbioticsMiddle Agedmedicine.diseasebiology.organism_classificationCrossover studyLactobacillus reuteriDental ImplantationTreatment OutcomeCytokinesPeriodonticsFemalebusinessTabletsJournal of Periodontal Research
researchProduct