Transcatheter Mitral Valve Repair: Single Stage Combo Approach

2019

Malemedicine.medical_specialtyCardiac CatheterizationTransesophagealCardiac Valve AnnuloplastyText miningmedicine80 and overHumansAged; Aged 80 and over; Cardiac Catheterization; Cardiac Valve Annuloplasty; Echocardiography Transesophageal; Heart Valve Prosthesis Implantation; Humans; Male; Middle Aged; Mitral Valve; Mitral Valve Insufficiency; Tomography X-Ray ComputedTomographyAgedAged 80 and overHeart Valve Prosthesis Implantationbusiness.industrySingle stageMitral Valve InsufficiencyGeneral MedicineMiddle AgedSurgeryX-Ray ComputedEchocardiographyMitral ValveTranscatheter mitral valve repairbusinessTomography X-Ray ComputedEchocardiography Transesophageal
researchProduct

Initial Experience in the Treatment of Extensive Iliac Artery Aneurysms With the Nellix Aneurysm Sealing System.

2016

Purpose: To assess the feasibility and effectiveness of the Nellix prosthesis in the treatment of common iliac artery aneurysms. Methods: Between May 2013 and June 2015, 230 patients underwent implantation of the Nellix device at 2 institutions. Fifty of these patients (mean age 76 years; 35 men) were identified as having 60 common iliac artery aneurysms (CIAAs) with a median diameter of 4 cm (range 3.5–7). The majority of patients had aortoiliac aneurysms (5, 70%), 10 (20%) had isolated CIAAs, and 5 (10%) had iliac anastomotic aneurysms after aortoiliac bypass. In 20 patients, the iliac aneurysm was the indication for the intervention; in the other 30 patients, the endovascular iliac repa…

Malemedicine.medical_specialtyComputed Tomography Angiographymedicine.medical_treatment030204 cardiovascular system & hematologyAnastomosisProsthesis DesignProsthesisIliac Artery03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicineAneurysmmedicine.arterymedicineHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineIliac AneurysmAgedAged 80 and overIliac arterybusiness.industryEndovascular ProceduresMean ageMiddle Agedmedicine.diseaseInternal iliac arteryCommon iliac arterySurgeryBlood Vessel ProsthesisTreatment OutcomeRegional Blood FlowIliac AneurysmFeasibility StudiesSurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicinebusinessJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Evaluation of ultrasound transmission velocity and 3-dimensional radiology in different bone types for dental implantology: a comparative ex vivo stu…

2013

Objective To evaluate ultrasound transmission velocity (UTV) for assessment of mechanical bone quality, an ex vivo comparison of different bone types measured with UTV, 2-dimensional (2D) histomorphometry and with 3-dimensional (3D) radiology (cone-beam computerized tomography [CBCT], computerized microtomography [μCT]) was conducted. Study Design Clinical cortical, cancellous, and mixed bone (each n = 6) was measured via UTV (m/s), CBCT (white pixel/black pixel ratio [WP/BP]), μCT (bone volume/total volume [μBV/TV]), and histomorphometry (bone volume/total volume [hBV/TV]). UTV values were correlated with 2D-histomorphometry and 3D-radiologic results. Results For the cortical, cancellous, …

Malemedicine.medical_specialtyCone beam computed tomographyX-ray microtomographyBone densitySwineTransducersRibsBone and BonesPathology and Forensic MedicineIliumDental implantologyImaging Three-DimensionalBone DensitymedicineImage Processing Computer-AssistedAnimalsRadiology Nuclear Medicine and imagingDentistry (miscellaneous)UltrasonicsUltrasonographybusiness.industryUltrasoundDental Implantation EndosseousX-Ray MicrotomographyCone-Beam Computed TomographySurgeryRadiologyTomographyOral SurgerybusinessBone volumeEx vivoOral surgery, oral medicine, oral pathology and oral radiology
researchProduct

Visual and optical performance with the ReZoom multifocal intraocular lens

2011

Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…

Malemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityProsthesis DesignRefraction OcularContrast SensitivityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularWavefrontVision Binocularbusiness.industryAberrometryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyFemalemedicine.symptombusinessEuropean Journal of Ophthalmology
researchProduct

ICD Implantation in infants and small children: the extracardiac technique.

2007

There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…

Malemedicine.medical_specialtyDefibrillationmedicine.medical_treatmentAnterior wallElectric Countershock030204 cardiovascular system & hematologyProsthesis Implantation03 medical and health sciences0302 clinical medicinemedicineHumans030212 general & internal medicineLead (electronics)Childbusiness.industrySmall childrenInfantArrhythmias CardiacGeneral MedicineImplantable cardioverter-defibrillator3. Good healthIcd implantationSurgeryDefibrillators Implantablemedicine.anatomical_structureTreatment OutcomeVentricleChild PreschoolFemaleCardiology and Cardiovascular MedicinebusinessVertebral columnPacing and clinical electrophysiology : PACE
researchProduct

Prospective visual evaluation of apodized diffractive intraocular lenses

2006

To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…

Malemedicine.medical_specialtyDistance visual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularSurveys and QuestionnairesOphthalmologymedicineHumansContrast (vision)In patientProspective StudiesAgedmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyIntraocular lensesPatient SatisfactionQuality of LifeOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.

2011

PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…

Malemedicine.medical_specialtyDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeNear visual acuityFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicinePhacoemulsificationPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyHyperopiaTreatment Outcome030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Prospective study of the Acri.LISA bifocal intraocular lens

2007

To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensCataractContrast SensitivityNear acuityLens Implantation IntraocularOphthalmologyHumansMedicineContrast (vision)Prospective StudiesProspective cohort studyAgedmedia_commonLenses IntraocularVision BinocularPhacoemulsificationMonocularbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation

2007

Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityEmmetropiaIntraocular lensProsthesis DesignOphthalmoscopyTonometry OcularLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularClear lens extractionPhacoemulsificationmedicine.diagnostic_testbusiness.industryPhacoemulsificationPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOptometryFemalesense organsbusinessOphthalmology
researchProduct

Renewed endovascular repair for recurrent acute abdominal aortic aneurysm

2008

The aim of the study was to describe the successful endovascular management of a patient who was admitted urgently with a second episode of acute abdominal aortic aneurysm (AAA) 30 months after emergency endovascular abdominal aortic aneurysm repair (eEVAR) for a ruptured AAA. The patient, an 84 year-old male physician, presented with severe acute abdominal and back pain. Contrast-enhanced computer tomography scanning showed type III endoleak owing to complete disconnection of both graft limbs and the prosthetic main body. Treatment consisted of acute stent-grafting with two bridging stent-grafts to seal the endoleak and reline the graft. The patient is alive and well 6 months postoperative…

Malemedicine.medical_specialtyEndoleak type IIIRecurrent acuteSettore MED/22 - Chirurgia VascolareBlood Vessel Prosthesis ImplantationPostoperative ComplicationsRecurrenceEndovascular repairBack painmedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesAcute abdominal aortic aneurysmAged 80 and overEndoleak type IIbusiness.industrymedicine.diseaseAbdominal aortic aneurysmSurgerysurgical procedures operativeTreatment Outcomecardiovascular systemEmergency MedicineRadiologymedicine.symptombusinessTomography X-Ray ComputedAortic Aneurysm Abdominal
researchProduct