Search results for "IMPLANTATION"
showing 10 items of 733 documents
Cochlear implant complications and failures
2010
Abstract Introduction Cochlear implantation is a relatively safe surgery performed on profound bilateral hearing loss patients. Its surgical indications have increased and the age of implantation has decreased over the last years. As with any other surgery, it presents complications; device failure is one of the most important, given its potential risk for the need to explant and reimplant the device. Objective To evaluate cochlear implant complications, determine possible causes and discuss medical and surgical management. Material and methods A retrospective study of cochlear implants was performed. A total of 246 implants over an eleven-year period were evaluated. The sample consisted of…
Comparative Study Between Unilateral and Bilateral Cochlear Implantation in Children of 1 and 2 Years of Age
2016
Abstract Introduction The studies that have evaluated the effectiveness of bilateral cochlear implantation in children suggest an improvement in hearing about sound localisation and speech discrimination. In this paper we show the differences in audio-linguistic achievements with early bilateral cochlear implantation versus unilateral, and differences between simultaneous and sequential bilateral implantation. Material and methods We present 88 children with bilateral profound sensorineural hearing loss, treated with bilateral cochlear implantation in 32 cases and unilateral in 56 cases, during the first 12 months (27 children) of life and between 12 and 24 months (61 children). We conducte…
Panoramic and tomographic implant studies: role in the diagnosis of sinus disorders.
2009
Objective: To study the presence of sinus disorders and their diagnosis based on clinical and radiographic findings, correlating their presence with tomography tests and panoramic radiography. Study design: We conducted a retrospective study on 152 patients who were seeking implant treatment, thereby allowing us to evaluate 42 patients who had abnormal sinuses. The patients underwent an evaluation of their medical history as well a clinical examination, panoramic radiography and tomographic study. Results: The average age of the patient was 59.8 years old, and 54.76% of the group were males and 45.23% were females. Prior respiratory disorders were present in 52.38% of the patients, and 57.3…
A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm
2013
We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation. © Turkish Society of Radiology 2012.
Endovascular treatment options for complex abdominal aortic aneurysms
2015
Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …
Optical and visual performance of diffractive intraocular lens implantation after myopic laser in situ keratomileusis
2008
To evaluate the optical and visual quality in eyes with diffractive intraocular lenses (IOLs) after myopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected visual acuity (BCVA [distance]) at 12.5%, 25.0%, and 100% contrasts under photopic and mesopic conditions; best distance-corrected near acuity; corneal total higher-order aberrations (HOAs); and optical quality by modulation transfer function (MTF) were measured after myopic LASIK in eyes with a spherical AcrySof ReSTOR SN60D3 IOL or an aspheric Acri.LISA 366D IOL and phakic eyes (control).Under photopic conditions at 100% contrast, the BCVA was 0.1 logMAR or better in all g…
Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis
2010
To evaluate distance, intermediate, and near visual quality in eyes with diffractive intraocular lens (IOL) implantation after previous hyperopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Corrected distance visual acuity (CDVA) at 12.5%, 25.0%, and 100% contrast levels under photopic and mesopic conditions; uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, defocus curves, and corneal higher-order aberrations (HOAs) were measured in eyes that had AcrySof Restor SN60D3 spherical IOL implantation (study group) and in phakic eyes (control group) after hyperopic LASIK.Under photopic conditions at 100% contrast, …
Toric intraocular lens versus opposite clear corneal incisions to correct astigmatism in eyes having cataract surgery.
2009
To compare toric intraocular lens (IOL) implantation with paired opposite clear corneal incisions (OCCIs) for astigmatism correction in patients having cataract surgery.Ophthalmology Service, Donostia Hospital, San Sebastián, Spain.This randomized prospective clinical study comprised eyes with more than 1.00 diopter (D) of preexisting corneal astigmatism. One group had AcrySof toric IOL implantation and the other, paired 2.75 mm/3.20 mm OCCIs in the steep axis with spherical IOL implantation. Uncorrected (UCVA) and best corrected (BCVA) visual acuity, refraction, corneal and total higher-order aberrations (HOAs), photopic and mesopic contrast sensitivity, and toric IOL axis were measured 3 …
Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism
1999
Abstract A 57-year-old man experienced a decrease in visual function because of cataract formation. Corneal astigmatism was 13.4 diopters (D) because he had had a penetrating keratoplasty 27 years before. Cataract surgery was planned, and biometric data for toric intraocular lens (IOL) implantation were collected for the manufacture of a custom IOL. After phacoemulsification, a toric poly(methyl methacrylate) (PMMA) IOL of +19.0 D spherical and +12.0 D cylindrical power was implanted via a sclerocorneal tunnel incision. Three months postoperatively, corneal astigmatism was 14.3 D and best corrected visual acuity (BCVA), 20/25. Postoperative refraction (+1.5 −3.0 × 90) and BCVA remained stab…
How Can We Identify the Best Implantation Site for an ECG Event Recorder?
2000
ZELLERHOFF, C., et al.: How Can We Identify the Best Implantation Site for an ECG Event Recorder? The aim of this study was to show how to find the preferable implantation site for an ECG event recorder (ECG-ER). We compared the quality of bipolar ECG recordings (4-cm electrode distance, vertical position) in 65 patients at the following sites: left and right subclavicular, left and right anterior axillary line (4th-5th interspace), left and right of the sternum (4th-5th interspace), heart apex, and subxyphoidal. The results were compared to the standard ECG lead II. In 30 patients, an additional comparison between vertical and horizontal ECG registrations was done using the same sites. ECG…