Search results for "IMPLANTATION"

showing 10 items of 733 documents

Cochlear implant complications and failures

2010

Abstract Introduction Cochlear implantation is a relatively safe surgery performed on profound bilateral hearing loss patients. Its surgical indications have increased and the age of implantation has decreased over the last years. As with any other surgery, it presents complications; device failure is one of the most important, given its potential risk for the need to explant and reimplant the device. Objective To evaluate cochlear implant complications, determine possible causes and discuss medical and surgical management. Material and methods A retrospective study of cochlear implants was performed. A total of 246 implants over an eleven-year period were evaluated. The sample consisted of…

Malemedicine.medical_specialtyPotential riskbusiness.industryBilateral hearing lossmedicine.medical_treatmentRetrospective cohort studyGeneral MedicineSafe surgeryProsthesis FailureSurgeryCochlear ImplantsPostoperative ComplicationsChild PreschoolCochlear implantHumansMedicineFemaleChildCochlear implantationbusinessComplicationDevice failureRetrospective StudiesActa Otorrinolaringologica (English Edition)
researchProduct

Comparative Study Between Unilateral and Bilateral Cochlear Implantation in Children of 1 and 2 Years of Age

2016

Abstract Introduction The studies that have evaluated the effectiveness of bilateral cochlear implantation in children suggest an improvement in hearing about sound localisation and speech discrimination. In this paper we show the differences in audio-linguistic achievements with early bilateral cochlear implantation versus unilateral, and differences between simultaneous and sequential bilateral implantation. Material and methods We present 88 children with bilateral profound sensorineural hearing loss, treated with bilateral cochlear implantation in 32 cases and unilateral in 56 cases, during the first 12 months (27 children) of life and between 12 and 24 months (61 children). We conducte…

Malemedicine.medical_specialtyProfound sensorineural hearing lossHearing Loss Sensorineuralmedicine.medical_treatmentAudiologyHearing Loss Bilateral03 medical and health sciences0302 clinical medicineCochlear implantSecondary Preventionotorhinolaryngologic diseasesmedicineHumans030223 otorhinolaryngologyCochlear implantationSecondary preventionmedicine.diagnostic_testbusiness.industryHearing TestsAge FactorsFollow up studiesInfantGeneral Medicinemedicine.diseaseCochlear ImplantationCochlear ImplantsTreatment OutcomeChild PreschoolPattern Recognition PhysiologicalAudiometry Pure-ToneFemaleSensorineural hearing lossImplantAudiometrybusiness030217 neurology & neurosurgeryFollow-Up StudiesActa Otorrinolaringologica (English Edition)
researchProduct

Panoramic and tomographic implant studies: role in the diagnosis of sinus disorders.

2009

Objective: To study the presence of sinus disorders and their diagnosis based on clinical and radiographic findings, correlating their presence with tomography tests and panoramic radiography. Study design: We conducted a retrospective study on 152 patients who were seeking implant treatment, thereby allowing us to evaluate 42 patients who had abnormal sinuses. The patients underwent an evaluation of their medical history as well a clinical examination, panoramic radiography and tomographic study. Results: The average age of the patient was 59.8 years old, and 54.76% of the group were males and 45.23% were females. Prior respiratory disorders were present in 52.38% of the patients, and 57.3…

Malemedicine.medical_specialtyRadiographyPhysical examinationDental disorderRadiography PanoramicParanasal Sinus DiseasesMedicineHumansMedical historyGeneral DentistrySinus (anatomy)Retrospective Studiesmedicine.diagnostic_testbusiness.industryRetrospective cohort studyMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Dental Implantationmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryFemaleRadiologyTomographyImplantbusinessTomography X-Ray ComputedMedicina oral, patologia oral y cirugia bucal
researchProduct

A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm

2013

We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation. © Turkish Society of Radiology 2012.

Malemedicine.medical_specialtyRadiology Nuclear Medicine and ImagingBridging (networking)Common iliac aneurysmProsthesis DesignIliac ArterySettore MED/22 - Chirurgia VascolareWire-loop techniqueFollow-Up StudieBlood Vessel Prosthesis ImplantationmedicineStentHumanscardiovascular diseasesAgedEndovascular; Iliac aneurysm; Wire-loop technique; Aged; Aortic Aneurysm Abdominal; Blood Vessel Prosthesis Implantation; Follow-Up Studies; Humans; Iliac Aneurysm; Iliac Artery; Male; Prosthesis Design; Treatment Outcome; Blood Vessel Prosthesis; Stents; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular MedicineRuptured abdominal aortic aneurysmEndovascularbusiness.industrySynthetic graftStandard techniqueSurgeryBlood Vessel ProsthesisIliac aneurysmBlood Vessel Prosthesisurgical procedures operativemedicine.anatomical_structureTreatment OutcomeStentsRadiologybusinessCardiology and Cardiovascular MedicineWire loopArteryFollow-Up StudiesAortic Aneurysm AbdominalHuman
researchProduct

Endovascular treatment options for complex abdominal aortic aneurysms

2015

Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …

Malemedicine.medical_specialtyRadiology Nuclear Medicine and ImagingTime Factorsmedicine.medical_treatmentCustom-made fenestrated endovascular aneurysm repairProsthesis DesignRevascularizationAortographyEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareBlood Vessel Prosthesis ImplantationAortic aneurysmAneurysmBlood vessel prosthesismedicine.arterymedicineHumansRenal arterychimney endovascular aneurysm repairVascular PatencyAgedRetrospective StudiesAged 80 and overbusiness.industryhomemade fenestrated endovascular aneurysm repairEndovascular Procedureshomemade fenestrated endovascular aneurysm repair; Custom-made fenestrated endovascular aneurysm repair; chimney endovascular aneurysm repairPerioperativeMiddle Agedmedicine.diseaseBlood Vessel ProsthesisSurgeryVisceraTreatment OutcomeRegional Blood FlowFemaleStentsRadiologyTomography X-Ray ComputedbusinessCardiology and Cardiovascular MedicineBlood Flow VelocityAortic Aneurysm AbdominalAbdominal surgery
researchProduct

Optical and visual performance of diffractive intraocular lens implantation after myopic laser in situ keratomileusis

2008

To evaluate the optical and visual quality in eyes with diffractive intraocular lenses (IOLs) after myopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected visual acuity (BCVA [distance]) at 12.5%, 25.0%, and 100% contrasts under photopic and mesopic conditions; best distance-corrected near acuity; corneal total higher-order aberrations (HOAs); and optical quality by modulation transfer function (MTF) were measured after myopic LASIK in eyes with a spherical AcrySof ReSTOR SN60D3 IOL or an aspheric Acri.LISA 366D IOL and phakic eyes (control).Under photopic conditions at 100% contrast, the BCVA was 0.1 logMAR or better in all g…

Malemedicine.medical_specialtyRefractive errorPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisIntraocular lensProsthesis DesignCataractPupilContrast SensitivityLens Implantation IntraocularOphthalmologyMyopiamedicineHumansProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryLASIKPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyOptometryFemaleLasers ExcimerSurgerysense organsbusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis

2010

To evaluate distance, intermediate, and near visual quality in eyes with diffractive intraocular lens (IOL) implantation after previous hyperopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Corrected distance visual acuity (CDVA) at 12.5%, 25.0%, and 100% contrast levels under photopic and mesopic conditions; uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, defocus curves, and corneal higher-order aberrations (HOAs) were measured in eyes that had AcrySof Restor SN60D3 spherical IOL implantation (study group) and in phakic eyes (control group) after hyperopic LASIK.Under photopic conditions at 100% contrast, …

Malemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentKeratomileusis Laser In SituMesopic VisionVisual AcuityIntraocular lensKeratomileusisRefraction OcularCohort StudiesLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesAgedPostoperative CarePhacoemulsificationColor Visionbusiness.industryLASIKPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Toric intraocular lens versus opposite clear corneal incisions to correct astigmatism in eyes having cataract surgery.

2009

To compare toric intraocular lens (IOL) implantation with paired opposite clear corneal incisions (OCCIs) for astigmatism correction in patients having cataract surgery.Ophthalmology Service, Donostia Hospital, San Sebastián, Spain.This randomized prospective clinical study comprised eyes with more than 1.00 diopter (D) of preexisting corneal astigmatism. One group had AcrySof toric IOL implantation and the other, paired 2.75 mm/3.20 mm OCCIs in the steep axis with spherical IOL implantation. Uncorrected (UCVA) and best corrected (BCVA) visual acuity, refraction, corneal and total higher-order aberrations (HOAs), photopic and mesopic contrast sensitivity, and toric IOL axis were measured 3 …

Malemedicine.medical_specialtyRefractive errorgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismContrast SensitivityCorneaPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesIntraoperative ComplicationsDioptreAgedLenses IntraocularPhacoemulsificationmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyPhacoemulsificationCataract surgeryCorneal topographymedicine.diseaseeye diseasesSensory SystemsToric lensOphthalmologySurgeryFemalesense organsbusinessJournal of cataract and refractive surgery
researchProduct

Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism

1999

Abstract A 57-year-old man experienced a decrease in visual function because of cataract formation. Corneal astigmatism was 13.4 diopters (D) because he had had a penetrating keratoplasty 27 years before. Cataract surgery was planned, and biometric data for toric intraocular lens (IOL) implantation were collected for the manufacture of a custom IOL. After phacoemulsification, a toric poly(methyl methacrylate) (PMMA) IOL of +19.0 D spherical and +12.0 D cylindrical power was implanted via a sclerocorneal tunnel incision. Three months postoperatively, corneal astigmatism was 14.3 D and best corrected visual acuity (BCVA), 20/25. Postoperative refraction (+1.5 −3.0 × 90) and BCVA remained stab…

Malemedicine.medical_specialtyRefractive errorgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismRefraction OcularCataractCorneaHigh astigmatismLens Implantation IntraocularOphthalmologyHumansPolymethyl MethacrylateMedicineDioptreLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismCorneal TopographyPhacoemulsificationMiddle AgedCataract surgeryequipment and suppliesmedicine.diseaseeye diseasesSensory SystemsSurgeryToric lensOphthalmologySurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

How Can We Identify the Best Implantation Site for an ECG Event Recorder?

2000

ZELLERHOFF, C., et al.: How Can We Identify the Best Implantation Site for an ECG Event Recorder? The aim of this study was to show how to find the preferable implantation site for an ECG event recorder (ECG-ER). We compared the quality of bipolar ECG recordings (4-cm electrode distance, vertical position) in 65 patients at the following sites: left and right subclavicular, left and right anterior axillary line (4th-5th interspace), left and right of the sternum (4th-5th interspace), heart apex, and subxyphoidal. The results were compared to the standard ECG lead II. In 30 patients, an additional comparison between vertical and horizontal ECG registrations was done using the same sites. ECG…

Malemedicine.medical_specialtySternumbusiness.industryP waveImplantation SiteAxillary linesGeneral MedicineMiddle AgedQT intervalElectrodes ImplantedProsthesis ImplantationElectrocardiographyQRS complexInternal medicineHorizontal position representationCardiologymedicineHumansFemalecardiovascular diseasesCardiology and Cardiovascular MedicinebusinessStandard ECGPacing and Clinical Electrophysiology
researchProduct