Search results for "IMPLANTATION"
showing 10 items of 733 documents
Clinical magnification and residual refraction after implantation of a double intraocular lens system in patients with macular degeneration
2007
Purpose To evaluate the efficacy of a standard double intraocular lens (IOL) system (IOL-Vip) in patients with low vision and central scotoma due to macular degeneration and assess the predictability of the residual refraction and magnification. Setting Ophthalmology Department, Hospital General Universitario, Valencia, Spain. Methods This interventional prospective noncomparative case series comprised 13 consecutive surgical procedures in 10 patients with central scotoma. Follow-up was 12 months. Evaluation included the difference between preoperative and postoperative best corrected visual acuity (BCVA), refraction, position of the IOLs, endothelial cell density, and occurrence of postope…
Prevention of hyperopic surprise after LASIK in patients with refractive multifocal intraocular lenses.
2011
Purpose. Three cases of patients who developed a similar hyperopic defect in refraction following laser in situ keratomileusis (LASIK) after multifocal intraocular lens (IOL) implantation are described. Methods. Ophthalmologic evaluation including refractive status, corrected and uncorrected visual acuity (both at far and near), and corneal topography in patients presenting similar hyperopic refractive surprise in one eye as a result of LASIK refinement of residual ametropia after refractive multifocal IOL implantation. Results. Laser in situ keratomileusis enhancement for residual ametropia of −1.00 to −1.50 D in patients with a prior implantation of refractive multifocal IOL resulted in a…
One-Year Outcomes with New-Generation Multifocal Intraocular Lenses
2007
Purpose: To compare new-generation multifocal intraocular lenses (IOLs) with monofocal IOLs. Design: Randomized prospective clinical trial. Participants: Sixty-two consecutive patients with cataract, seen between January of 2005 and January of 2006 at the Department of Ophthalmology of Palermo University Hospital in Italy, were bilaterally implanted with monofocal (AR 40, Advanced Medical Optics [AMO], Santa Ana, CA; 15 patients), multifocal refractive (Array SA40N, AMO; 16 patients), multifocal refractive (ReZoom, AMO; 15 patients), or multifocal diffractive pupil-independent (Tecnis ZM900, AMO; 16 patients) IOLs. Intervention: Bimanual phacoemulsification. Main Outcome Measures: Primary o…
Surgical conversion with graft salvage as a definitive treatment for persistent type II endoleak causing sacenlargement
2015
Objective The goal of this study was to present open surgical conversion with graft salvage or "semiconversion" as a definitive and safe treatment for untreatable and persistent type II endoleaks causing sac enlargement after endovascular aneurysm repair. Methods Between January 2001 and December 2014, 25 of 1623 endovascular aortic repair (EVAR) patients were selected as candidates for open semiconversion. The indication was persistent type II endoleak in 13 patients (12 of whom received previous attempts of embolization), type I and II endoleak in 2 patients, and sac growth without imaging evidence of endoleak in the other 10. After the infrarenal aorta was prepared (via a retroperitoneal…
Enhanced angiogenesis in the 3D dynamic responsive implant for inguinal hernia repair ProFlor
2021
Biologic response to hernia prostheses represents a continuous source of debate. Conventional hernia meshes, in their typical static, passive configuration have been used for decades to reinforce the herniated abdominal wall. These flat implants, mainly fixated with sutures or tacks, induce poor quality fibrotic ingrowth that shrinks the mesh. In groin hernia repair, flat meshes are applied in the delicate inguinal surrounding where uncontrolled development of a scar plate can impair movement and may incorporate the sensitive nerves crossing this area. Complications deriving from mesh fixation and nerve entrapment are frequent and unpleasant for patients. To remedy these problems, a multila…
Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation
2003
Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…
Complications of guided surgery and immediate loading in oral implantology: a report of 12 cases.
2011
Objectives: The growing interest in minimally invasive surgery, together with the possibility of fitting prostheses with immediate function, have led to the development of software capable of planning and manufacturing a surgical guide and prosthesis that can be placed upon conclusion of the implant surgery step. The present study evaluates the surgical and prosthetic complications of implant treatment with the guided surgery technique, together with patient comfort during and after treatment. Patients and methods: A retrospective observational study was made of 19 patients with partially or totally edentulous upper and/or lower maxillae, involving the placement of a total of 122 implants. …
Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.
2005
To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…
Sphincter-like motion following machanical dilation of the internal inguinal ring during indirect inguinal hernia procedure
2008
INTRODUCTION: Even today, there is still great speculation as to the underlying pathogenesis of inguinal hernia. As a result, it could be extrapolated that the vast majority of repairs are based upon conjecture. Most current repairs are founded upon the principle of "closing the defect" in the anatomy, either by suturing closed under tension, covering with a mesh or obliterating the defect with a plug. Many variants of each method are refined to achieve better clinical outcomes. Yet few, if any, strive to understand a fundamental question: "What has gone wrong with the normal physiological and anatomical mechanisms that prevent abdominal structures protruding through the abdominal wall?" We…
[Penile Flexiflate® Surgitek prosthesis explant and simultaneous three-component hydraulic Titan® Alpha 1 prosthesis implantation, with double incisi…
2010
Introduction and Objectives We treated a 45 years old patient, suffering from diabetes mellitus since childhood, with retinal, neurovascular and kidney complications. In 1988, for erectile dysfunction (ED) resistant to medical injective treatment, the patient underwent ligation of the dorsal vein of the penis without any result. In 1989 a Flexiflate® hydraulic prosthesis was implanted with resolution of ED. In 2005 the patient underwent simultaneous kidney and pancreas transplant with a trans-laparotomic approach for end stage renal disease and diabetes mellitus. In 2009, because of the Flexiflate® Surgitek malfunction, the patient underwent explantation of the Flexiflate® prosthesis and si…