Search results for "IMPLANTS"
showing 10 items of 505 documents
Stability and marginal bone loss in implants placed using piezoelectric osteotomy versus conventional drilling: systematic review and meta-analysis.
2021
Background The main objective of this systematic review was to compare primary and secondary implant stability between placement with piezoelectric osteotomy and conventional drilling, comparing marginal bone losses as a secondary objective. Material and Methods An electronic search was conducted using PubMed (MEDLINE), Scopus, and Cochrane Library (Wiley) databases, besides a manual search. Results A total of 153 articles were retrieved, 39 from Pubmed, 44 from Scopus, and 70 from the Cochrane Library. After removing duplicates, 112 articles (1 from the manual search) were screened, and 9 were finally selected for qualitative and statistical analyses. Conclusions Piezoelectric surgery is a…
Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, osseodensification: an in vitro study
2020
Background Primary stability is an important key determinant of implant osseointegration. We investigated approaches to improve primary implant stability using a new drilling technique termed osseodensification (OD), which was compared with the conventional under-drilling (UD) method utilized for low-density bones. Material and Methods We placed 55 conical internal connection implants in each group, in 30 low-density sections of pig tibia. The implants were placed using twist drill bits in both groups; groups Under Drilling (UD) and Osseodensification (OD) included bone sections subjected to conventional UD and OD drilling, respectively. Before placing the implants, we randomized the bone s…
Recurrent central giant cell granuloma in the mandible: surgical treatment and dental implant restoration.
2007
Central giant cell granuloma is an uncommon benign intraosseus lesion of jaws. Traditional treatment has been local curettage, although aggressive sub-types have a high tendency to recur. This patient report describes a recurrent central giant cell granuloma involving the body of the mandible in a 48-year-old-woman. Initial treatment of lesion consisted of curettage and peripheral ostectomy. When recurrence was detected one year later, an en bloc resection and defect regeneration with a composite bone graft of autogenous bone, xenograft, and autologous platelet-rich plasma was carried out. Adequate new bone formation was observed during follow-up of 24 months. Two dental implants were place…
Analysis of the use of expansion osteotomes for the creation of implant beds. Technical contributions and review of the literature.
2006
La atrofia ósea severa del maxilar superior compromete e incluso, en ocasiones, impide la colocación de implantes. Con la expansión ósea mediante osteodilatadores se evita usar instrumentos rotatorios, no se produce calor ni se elimina hueso y se simplifica el tratamiento quirúrgico permitiendo la colocación de fijaciones sin recurrir a tratamientos más complejos. Presentamos una revisión de la técnica de expansión maxilar mediante osteodilatadores, describiendo las principales indicaciones, ventajas e inconvenientes de este procediminiento quirúrgico. Sometimes, the severe superior maxillary atrophy compromises and even impide oral implants treatment. The use of rotatory instruments (drill…
Is clinical experience important for obtaining the primary stability of dental implants with aggressive threads? An ex vivo study
2018
GECKILI, ONUR/0000-0002-7852-3915; dayan, suleyman cagatay/0000-0003-3081-9618; Bilhan, Hakan/0000-0003-1787-3003 WOS:000460131200015 PubMed ID: 30818319 Background: The aim of this study was to investigate the clinicians' experience on maintaining the primary stability of implants with aggressive threads belonging to a novel dental implant system. Material and Methods: Three hundred implants with aggressive threads were inserted in fresh bovine ribs mimicking Type IV bone by five clinicians which were classified according to their previous experience of total number of implant insertion. An independent examiner measured the primary stability of all implants after insertion by using resonan…
Modular Small Diameter Vascular Grafts with Bioactive Functionalities.
2015
We report the fabrication of a novel type of artificial small diameter blood vessels, termed biomimetic tissue-engineered blood vessels (bTEBV), with a modular composition. They are composed of a hydrogel scaffold consisting of two negatively charged natural polymers, alginate and a modified chitosan, N,O-carboxymethyl chitosan (N,O-CMC). Into this biologically inert scaffold two biofunctionally active biopolymers are embedded, inorganic polyphosphate (polyP) and silica, as well as gelatin which exposes the cell recognition signal, Arg-Gly-Asp (RGD). These materials can be hardened by exposure to Ca(2+) through formation of Ca(2+) bridges between the polyanions, alginate, N,O-CMC, and polyP…
Is the re-use of sterilized implant abutments safe enough? (Implant abutment safety)
2019
Background: The reuse of implant healing abutments is common in dental practice. Effective elimination of bacteria and viruses is accomplished by conventional sterilization. The aim of this work was to explore the eventual survival of microorganisms on sterilized healing abutments and to rule out the presence of transmissible organic material after standard procedures. Material and Methods: A total of 55 healing abutments previously used in patients will be washed and sterilized in a steam autoclave at 121oC for 15 min. Each healing abutment will be cultured in Brain Heart Infusion broth (BHI) under strict aseptic conditions. Besides, two control groups will be included: one of 3 unused hea…
Anterolateral thigh perforator flap made by customized 3D-printing fabrication of fixed positioning guide for oromaxillofacial reconstruction:a preli…
2022
Oromaxillofacial carcinomas frequently result in serious tissue defect due to enlarged resection for treating their extensive invasion, which require challenging reconstruction. Three-dimensional (3D) printing is an advanced technology which has greatly promoted the progress of craniomaxillofacial reconstructive surgery. This present study aimed to investigate the advantages of anterolateral thigh (ALT) perforator flap manufactured by 3D printing fixed positioning guide template in curing oromaxillofacial defect. Twenty patients with oromaxillofacial defects resulted from severe primary malignant tumors were divided into experimental group assisted by digital technique (n=8) and controlled …
Comparación de implantes transmucosos con cuello convergente frente a implantes sin cuello
2022
En los últimos años, se han realizado varios estudios clínicos y revisiones sistemáticas para comparar los implantes “Bone-level” (BL) y “Tissue-level”(TL). Aunque los resultados de la última revisión sistemática realizada al principio de este trabajo de tesis que analizaba las diferencias entre los implantes dentales BL y TL en sitios únicos o múltiples no mostraban diferencias en términos clínicos y radiográficos, probablemente debido al uso del “Platform-switching” en la implantología moderna. Por otro lado, hay muy pocos estudios en la literatura que comparen los implantes BL y TL en términos de propiedades mecánicas, especialmente los implantes TL con cuellos convergentes, que son cada…
Assessing osseointegration of metallic implants with boronized surface treatment
2020
Background Modification of endosteal implants through surface treatments have been investigated to improve osseointegration. Boronization has demonstrated favorable mechanical properties, but limited studies have assessed translational, in vivo outcomes. This study investigated the effect of implant surface boronization on bone healing. Material and Methods Two implant surface roughness profiles (acid etched, machined) in CP titanium (type II) alloy implants were boronized by solid-state diffusion until 10-15µm boron coating was achieved. The surface-treated implants were placed bilaterally into 5 adult sheep ilia for three and six weeks. Four implant groups were tested: boronized machined …