Search results for "INTERACTION"
showing 10 items of 5710 documents
Determination of alinidine in human plasma by high-performance liquid chromatography.
1981
Chromatographic Efficiency in Micellar Liquid Chromatography: Should it Be Still a Topic of Concern?
2013
Micellar liquid chromatography (MLC) was first proposed as an attractive alternative to avoid the use of organic solvents. It was soon apparent that pure micellar solutions yield poor efficiencies. This problem was remediated by the addition of a small amount of an organic solvent. However, the general opinion of the poor peak shape has prevailed as a handicap for MLC, in spite of the fact that the hybrid mode often offers similar or even improved efficiencies (for basic compounds) relative to that attained in the hydro-organic mode. Only the efficiencies for apolar non-ionizable compounds are still clearly inferior. This work describes the type of interactions and polarity changes with org…
Non-porous microparticulate supports in high-performance liquid chromatography (HPLC) of biopolymers — concepts, realization and prospects
1986
Retention mechanisms in micellar liquid chromatography.
2008
Micellar liquid chromatography (MLC) is a reversed-phase liquid chromatographic (RPLC) mode with mobile phases containing a surfactant (ionic or non-ionic) above its critical micellar concentration (CMC). In these conditions, the stationary phase is modified with an approximately constant amount of surfactant monomers, and the solubilising capability of the mobile phase is altered by the presence of micelles, giving rise to diverse interactions (hydrophobic, ionic and steric) with major implications in retention and selectivity. From its beginnings in 1980, the technique has evolved up to becoming a real alternative in some instances (and a complement in others) to classical RPLC with hydro…
Thin-layer chromatography of 2-methyl-4-chlorophenoxyacetic acid and its soil metabolites
1980
Abstract The thin-layer chromatography of 2-methyl-4-chlorophenoxyacetic acid, 4-chloro- o -cresol and 3-methyl-5-chlorocatechol and their pentafluorobenzyl derivatives has been studied on silica gel as adsorbent with 19 solvent systems. The best separation of the individual components occurred with toluene-benzene-acetic acid (2:2:1). Chloroform-diethyl ether-toluene (1:1:1) was suitable for the group separation of the pentafluorobenzyl derivatives.
Evaluation of advanced silica packings for the separation of biopolymers by high-perforamnce liquid chromatography
1987
Non-porous monodisperse 1.5-μm silicas were allowed to react with (A) and (B) N-acetylaminopropyltriethoxysilane to generate bonded phases useful in high-performance hydrophobic-interaction chromatography (HIC). Differences in the selectivity were observed between he amide and the ether phase. Peak capacities between 10 and 30 were achieved for several proteins with the amide and ether phase packed into columns of 36 × 8 mm I.D. and elution of the proteins under chromatographic conditions in which the gradient volume, VG, was held constant by varying the gradient time between 20 and 2.5 min and the flow-rate between 0.5 and 4.0 ml/min. The S values derived from the dependences of log k′ on …
Protocol to compare column performance applied to hydrophilic interaction liquid chromatography
2019
Abstract The lack of retention of highly polar solutes in liquid chromatography with reversed phase columns (RPLC) can be solved through the use of the hydrophilic interaction liquid chromatographic (HILIC) mode. Due to the complexity of the separation mechanisms in HILIC and the different factors that may have significant influence, the selection of the appropriate stationary phase plays a fundamental role in the development of analytical procedures to obtain good performance. In this work, the chromatographic performance of bare silica and six polar stationary phases with different functionalized groups (with neutral, cationic, anionic and zwitterionic character) are investigated. The beh…
Rapid detergent exchange in solutions of the membrane protein bacteriorhodopsin by preparative high-performance liquid chromatography (HPLC)
1984
High Submicellar Liquid Chromatography
2013
Surfactant addition above the critical micellar concentration (CMC), in reversed-phase liquid chromatography (RPLC), was proposed as a way to modify the selectivity and analysis time, giving rise to a chromatographic mode called micellar liquid chromatography (MLC). However, solutions containing only surfactant are too weak and yield poor peak shape. This was remediated by the addition of a small amount of organic solvent. To preserve the existence of micelles, in MLC high contents of organic solvent are avoided. Nevertheless, there is no reason to neglect the potentiality of mobile phases containing a surfactant above its CMC in water and a high organic solvent content (without micelles). …
Description of the Retention and Peak Profile for Chromolith Columns in Isocratic and Gradient Elution Using Mobile Phase Composition and Flow Rate a…
2014
The effect of the modifier concentration and flow rate on the chromatographic performance of a second generation Chromolith® RP-18e column, under isocratic and gradient elution with acetonitrile-water mixtures, was examined using four sulphonamides as probe compounds. The acetonitrile concentration was varied between 5 and 55% (v/v), and the flow rate between 0.1 and 5.0 mL/min, keeping the other factors constant. The changes in both retention and peak profile were modelled, and used to build simple plots, where the logarithm of the retention factor was represented against the modifier concentration (in gradient elution, against the initial modifier concentration), and the half-widths or wi…