Search results for "IPM"
showing 10 items of 1361 documents
Intraprocedural bowel cleansing with the JetPrep cleansing system improves adenoma detection.
2014
AIM: To investigate the impact of JetPrep cleansing on adenoma detection rates. METHODS: In this prospective, randomized, crossover trial, patients were blindly randomized to an intervention arm or a control arm. In accordance with the risk profile for the development of colorectal carcinoma, the study participants were divided into high-risk and low-risk groups. Individuals with just one criterion (age > 70 years, adenoma in medical history, and first-degree relative with colorectal cancer) were regarded as high-risk patients. Bowel preparation was performed in a standardized manner one day before the procedure. Participants in the intervention arm underwent an initial colonoscopy with sta…
High-definition imaging in endoscopic transsphenoidal pituitary surgery.
2011
Background The transsphenoidal approach to sellar lesions has evolved enormously since its first description in the early 20th century. Endoscopic surgical strategies have become an integral part of the surgical armamentarium. More recently, high-definition (HD) digital cameras with better image resolution were introduced, although their value for the surgical procedure remains equivocal. The purpose of this study was to compare the image quality of a standard-definition (SD) camera with a new HD camera. Methods A transsphenoidal pituitary adenomectomy was recorded simultaneously in HD and SD resolution. Eight experienced neurosurgeons were asked to identify predefined as well as not predef…
Contribution of IL-17-producing {gamma}{delta} T cells to the efficacy of anticancer chemotherapy.
2011
IL-17 production by γδ T cells is required for tumor cell infiltration by IFN-γ–producing CD8+ T cells and inhibition of tumor growth in response to anthracyclines.
Motion-Cuing Algorithms
2015
Objective:The aim of this study was to characterize the human response to motion-cuing algorithms (MCAs) by comparing users’ perception to several proposed objective indicators.Background:Other researchers have proposed several MCAs, but few improvements have been achieved lately. One of the reasons for this lack of progress is that fair comparisons between different algorithms are hard to achieve, for their evaluation needs to be performed with humans and the tuning process is slow.Method:This characterization is performed by means of a comparison of the subjective perception of vehicle simulation users (90 participants) against several proposed objective indicators that try to measure MCA…
Impact of physical exercise on sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system in people with Ty…
2019
AIMS To evaluate the sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system using reference blood glucose levels during moderate-intensity exercise while on either full or reduced basal insulin dose in people with Type 1 diabetes. METHODS Ten participants with Type 1 diabetes [four women, mean ± sd age 31.4 ± 9.0 years, BMI 25.5±3.8 kg/m2 , HbA1c 55±7 mmol/mol (7.2±0.6%)] exercised on a cycle ergometer for 55 min at a moderate intensity for 5 consecutive days at the clinical research facility, while receiving either their usual or a 75% basal insulin dose. After a 4-week washout period, participants performed the second exercise period having sw…
Curasan PRP kit vs. PCCS PRP system
2002
An important reason to improve methods of isolating platelet-rich plasma (PRP) is the potential use of autologous thrombocyte growth factors. In addition to discontinuous cell separation, two methods for extracting PRP that can be performed directly by the surgeon are now available. This study compared the suitability of these two methods for the preparation of PRP. Whole blood was drawn from 47 healthy donors (18 men, 29 women) aged 20-59 years (mean 29.9, SD 7.7). For each donor, PRP was separated by the PCCS method (PCCS Kit, 3i Implant Innovations, Palm Beach Gardens, FL, USA) and by the Curasan method (analogous to the PRP kit, Curasan, Kleinostheim, Germany). Thrombocyte counts differ…
A new method for the placement of brachytherapy probes in paranasal sinus and nasopharynx neoplasms
1999
Abstract Purpose: In afterloading therapy, the exact placement of the applicator is crucial for the result of radiotherapy. A deviation of few millimeters from the target leads to a significant reduction of radiation energy to the tumor. Methods and Materials: We present a new method using a computer-assisted device for three-dimensional placing of afterloading probes based on CT scans that allows for the exact placement. Results: Target points have been reached with an accuracy of 0.6 mm. Since 1991 we have used this technique for 24 clinical applications in 11 patients with recurrent neoplasms in the region of the paranasal sinuses and nasopharynx for palliative treatment. Conclusions: Th…
Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
2011
Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…
Imaging findings of liver resection using a bipolar radiofrequency electrosurgical device—Initial observations
2010
Abstract Objective To assess contrast-enhanced US (CEUS), computed tomography (CT) and magnetic resonance (MR) imaging findings and serial changes of the treated area at follow-up in patients who underwent liver resection using a bipolar radiofrequency electrosurgical device. Methods Imaging findings of 27 patients with resected hepatocellular carcinomas (HCCs) ( n = 24) and metastases ( n = 3) (mean size: 2.6 cm), were retrospectively evaluated. Two readers assessed: the (a) presence, (b) thickness, (c) shape and (d) echogenicity (CEUS)/attenuation (CT)/signal intensity (MR imaging) at coagulated site and the (e) presence of residual tumor of the bipolar radiofrequency electrosurgical de…
Prospective multicenter trial of capsule endoscopy in patients with chronic abdominal pain, diarrhea and other signs and symptoms (CEDAP-Plus Study)
2007
Background On the basis of the published data, capsule endoscopy cannot be recommended in patients whose only symptom is chronic abdominal pain. The present study therefore focused on the diagnostic yield of capsule endoscopy in patients with chronic abdominal pain who were also suffering from additional symptoms. Patients and methods A total of 50 patients with chronic abdominal pain, plus other symptoms singly or in combination were enrolled in this prospective multicenter trial. The "plus" symptoms or signs consisted of weight loss (> 10 % of body weight), inflammation shown by laboratory tests, chronic anemia, or suspected mid-gastrointestinal bleeding. Chronic diarrhea was recorded if …