Tonometers and infectious risk: myth or reality? Efficacy of different disinfection regimens on tonometer tips
2006
Purpose To evaluate the adequacy of common disinfection regimens for disposable tonometer tips and assess if disinfection of reusable prisms or the use of disposable tips is preferable. Methods We used disposable tonometer tips, using the same material and tip diameter of standard Goldmann tonometer prism. Strains of Pseudomonas aeruginosa, Staphylococcus aureus, Bacillus subtilis and Candida albicans were tested according to the European standard guidelines for disinfectants test. Antimicrobial effectiveness of the following disinfection practices has been assessed: dry wipe, Minuten wipes (Alpros), soaking in 3% hydrogen peroxide, 0.5% benzalkonium chloride, and 0.5% Pantasepts for 1, 5, …
Measurements of Silicon Photomultipliers Responsivity in Continuous Wave
2012
N-on-P and P-on-N Silicon Photomultipliers: Responsivity comparison in the continuous wave regime
2013
We report on the electrical and optical comparison, in continuous wave regime, of two novel classes of silicon photomultipliers fabricated in planar technology on silicon P-type and Ntype substrate respectively. A physical explanation of the experimental results is provided.
Measurements of Silicon Photomultipliers Responsivity
2012
We present some results on the optical characterization of Silicon Photomultipliers designed for medical imaging applications. In particular we will discuss our responsivity measurements performed with very low incident optical power and on a broad spectrum
Informe de las prácticas externas: Calibración de SiPM del plano de trazas del detector NEXT1-EL
2011
El objetivo de las prácticas externas realizadas en el Laboratorio de Reacciones Nucleares (IFIC) es familiarizarse con los sistemas de adquisición de datos de una cámara de Xenon gaseoso a alta presión (TPC), que es el elemento principal del experimento NEXT1-EL. Esta TPC es un prototipo de otra mayor que se instalará en el Laboratorio Subterráneo de Canfranc. En concreto, mis prácticas se han centrado en la caracterización y cálculo de ganancia de fotomultiplicadores de silicio (SiPM), detectores que se emplean en el plano de tracking de la TPC para visualizar la traza de las partículas ionizantes para poder hacer una selección topológica de los eventos de interés, candidatos a ser una de…
PPG/ECG Multisite Combo System Based on SiPM Technology
2019
Two versions of a PPG/ECG combined system have been realized and tested. In a first version a multisite system has been equipped by integrating 3 PPG optodes and 3 ECG leads, whereas in another setup a portable version has been carried out. Both versions have been realized by equipping the optical probes with SiPM detectors. SiPM technology is expected to bring relevant advantages in PPG systems and overcome the limitations of physiological information extracted by state of the art PPG, such as poor sensitivity of detectors used for backscattered light detection and motion artifacts seriously affecting the measurements repeatability and pulse waveform stability. This contribution presents t…
Photonic fractional Fourier transformer with a single dispersive device
2013
In this work we used the temporal analog of spatial Fresnel diffraction to design a temporal fractional Fourier transformer with a single dispersive device, in this way avoiding the use of quadratic phase modulators. We demonstrate that a single dispersive passive device inherently provides the fractional Fourier transform of an incident optical pulse. The relationships linking the fractional Fourier transform order and scaling factor with the dispersion parameters are derived. We first provide some numerical results in order to prove the validity of our proposal, using a fiber Bragg grating as the dispersive device. Next, we experimentally demonstrate the feasibility of this proposal by us…
Measurements of Silicon Photomultipliers Responsivity in Continuous Wave Regime
2013
We report on the electrical and optical characterization, in continuous wave regime, of a novel class of silicon photomultipliers fabricated in standard planar technology on a silicon p-type substrate. Responsivity measurements, performed with an incident optical power down to tenths of picowatts, at different reverse bias voltages and on a broad (340–820 nm) spectrum, will be shown and discussed. The device temperature was monitored, allowing us to give a physical interpretation of the measurements. The obtained results demonstrate that such novel silicon photomultipliers are suitable as sensitive power meters for low photon fluxes.
Baseline design of the filters for the LAD detector on board LOFT
2014
The Large Observatory for X-ray Timing (LOFT) was one of the M3 missions selected for the phase A study in the ESA's Cosmic Vision program. LOFT is designed to perform high-time-resolution X-ray observations of black holes and neutron stars. The main instrument on the LOFT payload is the Large Area Detector (LAD), a collimated experiment with a nominal effective area of ~10 m 2 @ 8 keV, and a spectral resolution of ~240 eV in the energy band 2-30 keV. These performances are achieved covering a large collecting area with more than 2000 large-area Silicon Drift Detectors (SDDs) each one coupled to a collimator based on lead-glass micro-channel plates. In order to reduce the thermal load onto …
Protein delivery based on uncoated and chitosan-coated mesoporous silicon microparticles
2011
Mesoporous silicon is a biocompatible, biodegradable material that is receiving increased attention for pharmaceutical applications due to its extensive specific surface. This feature enables to load a variety of drugs in mesoporous silicon devices by simple adsorption-based procedures. In this work, we have addressed the fabrication and characterization of two new mesoporous silicon devices prepared by electrochemistry and intended for protein delivery, namely: (i) mesoporous silicon microparticles and (ii) chitosan-coated mesoporous silicon microparticles. Both carriers were investigated for their capacity to load a therapeutic protein (insulin) and a model antigen (bovine serum albumin) …