Search results for "IPM"
showing 10 items of 1361 documents
Heated breathing tubes affect humidity output of circle absorber systems.
1993
Abstract Study Objective: To verify whether the airway climate in circle systems can be improved with heated breathing tubes. Design: Randomized, controlled, prospective clinical study. Setting: Operating theater of the Department of Maxillofacial Surgery. Patients: 26 adult patients undergoing prolonged anesthesia. Interventions: A total of 26 prolonged anesthetics were conducted in adult patients using a minimal fresh gas flow rate (0.6 L/min) and silicon breathing tubes (16 mm internal diameter) containing a heated coil. Group 1 ( n = 10 patients) was the control group; breathing tubes were unheated. In Group 2 ( n = 10 patients), breathing tubes were heated to 30°C. In Group 3 ( n = 6 p…
Photobleaching effects onin vivoskin autofluorescence lifetime
2015
The autofluorescence lifetime of healthy human skin was measured using excitation provided by a picosecond diode laser operating at a wavelength of 405 nm and with fluorescence emission collected at 475 and 560 nm. In addition, spectral and temporal responses of healthy human skin and intradermal nevus in the spectral range 460 to 610 nm were studied before and after photobleaching. A decrease in the autofluorescences lifetimes changes was observed after photobleaching of human skin. A three-exponential model was used to fit the signals, and under this model, the most significant photoinduced changes were observed for the slowest lifetime component in healthy skin at the spectral range 520 …
Clinical validation of embryo culture and selection by morphokinetic analysis: a randomized, controlled trial of the EmbryoScope.
2014
Objective To determine whether incubation in the integrated EmbryoScope time-lapse monitoring system (TMS) and selection supported by the use of a multivariable morphokinetic model improve reproductive outcomes in comparison with incubation in a standard incubator (SI) embryo culture and selection based exclusively on morphology. Design Prospective, randomized, double-blinded, controlled study. Setting University-affiliated private in vitro fertilization (IVF) clinic. Patient(s) Eight hundred forty-three infertile couples undergoing intracytoplasmic sperm injection (ICSI). Intervention(s) No patient intervention; embryos cultured in SI with development evaluated only by morphology (control …
Femtosecond laser versus mechanical microkeratome laser in situ keratomileusis for myopia: Metaanalysis of randomized controlled trials.
2011
Purpose To examine differences in efficacy, accuracy, safety, and changes in aberrations between femtosecond and mechanical microkeratome laser in situ keratomileusis (LASIK) for myopia. Setting Department of Ophthalmology, Shanghai First People's Hospital Affiliated to Shanghai Jiaotong University, Shanghai, China. Design Evidence-based manuscript. Methods Data sources, including PubMed, Medline, EMBASE, and Cochrane Controlled Trials Register, were searched to identify potentially relevant prospective randomized controlled trials. Primary outcome measures were efficacy (uncorrected distance visual acuity ≥20/20), accuracy (±0.50 diopter mean spherical equivalent), and safety (loss of ≥2 l…
Visual performance with simultaneous vision multifocal contact lenses.
2011
Purpose: The aim was to assess visual performance after PureVision high addition multifocal contact lens (PM) fitting through contrast sensitivity measured under different illumination levels for both distance and near. Methods: In a cross-over study, 20 presbyopic patients were randomly assigned to PM or spectacles. Near contrast sensitivity was measured with the Vistech VCTS 6500 system. Distance contrast sensitivity and distance visual acuity (VA) were measured with the Functional Vision Analyser under photopic (85 cd/m2) and mesopic (3.0 cd/m2) conditions, the latter also under two levels of induced glare: 1.0 lux and 28 lux. Near VA was measured by logMAR charts under approximately 8…
Ski Boots Do Not Impair Standing Balance by Restricting Ankle-Joint Mobility.
2018
Objective: This study was undertaken in order to provide new insight into sensorimotor control of posture when wearing high-shaft (HS) boots as ski boots. Background: Previous studies into the effects of HS boots on postural control have produced controversial results. Some studies reported postural control impairments with ski boots in bipedal postural tasks due to ankle movement restrictions without quantifying the actual restrictive effect of these boots and specifying the adaptations of the postural control system. Method: Eighteen young healthy subjects took part in the experiment. Bilateral postural control was assessed on stable and unstable surfaces, while standing barefoot or weari…
A European Study of the Performance and Safety of MINIject in Patients With Medically Uncontrolled Open-angle Glaucoma (STAR-II)
2020
Precis In this European study (STAR-II), MINIject, a novel, ab-interno, supraciliary MIGS device, effectively lowered intraocular pressure (IOP) and the need for IOP-lowering medications in patients with primary open-angle glaucoma. Purpose To evaluate the safety and performance of a minimally invasive supraciliary glaucoma drainage device (MINIject DO627, iSTAR Medical SA, Wavre, Belgium) for surgical treatment of primary open angle glaucoma in patients refractory to topical hypotensive medications. Methods In a prospective, interventional, single-arm, multi-center, European study (STAR-II), MINIject was successfully implanted in a standalone procedure in 29 of 31 patients in 8 sites in 3 …
Biportal neuroendoscopic microsurgical approaches to the subarachnoid cisterns. A cadaver study.
1996
A preclinical cadaver study was performed to develop the technique of biportal neuroendoscopic dissection in the subarachnoid space of the basal cisterns and to test the feasibility, utility, and safety of this new technique. In 23 fresh post-mortem adult human cadavers and 2 formalin-fixed adult human head specimen a total of 33 biportal endomicrosurgical dissections into and within the basal cisterns were carried out. Following suction of cerebrospinal fluid from the subarachnoid space 0 degree-, 30 degrees-, and 70 degrees-lens-scopes (Aesculap AG, Tuttlingen, Germany) with outer diameters of 4.2 mm and trochars with outer diameters of 5 to 6.5 mm were introduced into the surgical field.…
Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.
2005
To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany.In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometri…
Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome
2007
ABSTRACT PURPOSE: To compare the effects on contrast sensitivity of the IntraLase femtosecond laser for flap creation (IntraLASIK) and standard LASIK for myopia. METHODS: Two hundred eyes of 100 consecutive patients underwent LASIK treatment using the VISX S2 laser system. The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). Best spectacle-corrected contrast sensitivity was measured before and 6 months postoperatively in the IntraLASIK and mechanical LASIK groups. The IntraLASIK and mechanical LASIKinduced changes in contrast sensitivity were compared under photop…