Search results for "IPM"
showing 10 items of 1361 documents
Impact of crop species on bacterial community structure during anaerobic co-digestion of crops and cow manure
2008
The bacterial communities in three continuously stirred tank reactors co-digesting cow manure with grass silage, oat straw, and sugar beet tops, respectively, were investigated by 16S rRNA gene-based fingerprints and clone libraries. The analyses revealed both clearly distinct and similar phylotypes in the bacterial communities between the reactors. The major groups represented in the three reactors were Clostridia, unclassified Bacteria, and Bacteroidetes. Phylotypes affiliated with Bacilli or Deltaproteobacteria were unique to the sugar beet and straw reactor, respectively. Unclassified Bacteria dominated in sugar beet reactor while in the straw and grass reactor Clostridia was the domina…
SARS-CoV-2 Infection in Healthcare Professionals and General Population During “First Wave” of COVID-19 Pandemic: A Cross-Sectional Study Conducted i…
2021
On December 31, 2019, an outbreak of lower respiratory infections was documented in Wuhan caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Since the beginning, SARS-CoV-2 has caused many infections among healthcare workers (HCWs) worldwide. Aims of this study were: a. to compare the distribution among the HCWs and the general population of SARS-CoV-2 infections in Western Sicily and Italy; b. to describe the characteristics of HCWs infected with SARS-CoV-2 in the western Sicilian healthcare context during the first wave of the epidemic diffusion in Italy. Incidence and mean age of HCWs infected with SARS-CoV-2 were comparable in Western Sicily and in the whole Ita…
Baseline design of the thermal blocking filters for the X-IFU detector on board ATHENA
2014
ATHENA is an advanced X-ray observatory designed by a large European consortium to address the science theme "Hot and Energetic Universe" recently selected by ESA for L2 – the second Large-class mission within the Cosmic Vision science program (launch scheduled in 2028). One of the key instruments of the mission is the X-ray Integral Field Unit (X-IFU), an array of Transition Edge Sensor (TES) micro-calorimeters with high energy resolution (2.5 eV @ 6 keV) in the energy range 0.2÷12 keV, operating at the focal plane of a large effective area high angular resolution (5" HEW) grazing incidence X-ray telescope. The X-IFU operates at temperatures below 100 mK and thus requires a sophisticated c…
A Mössbauer cryostat equipped with a Gifford McMahon cryocooler
1989
A new cryostat for Mossbauer spectroscopic measurements has been developed around a cryogenerator of the Gifford McMahon type operating with helium gas in a closed circuit. Both source and absorber can be cooled to about 30K and the unwanted vibrations caused by the helium compression/expansion cycle have been limited to approximately 0.05–0.06 mms−1.
Imaging Cultural Heritage at Different Scales: Part I, the Micro-Scale (Manufacts)
2023
Applications of non-invasive sensing techniques to investigate the internal structure and surface of precious and delicate objects represent a very important and consolidated research field in the scientific domain of cultural heritage knowledge and conservation. The present article is the first of three reviews focused on contact and non-contact imaging techniques applied to surveying cultural heritage at micro- (i.e., manufacts), meso- (sites) and macro-scales (landscapes). The capability to infer variations in geometrical and physical properties across the inspected surfaces or volumes is the unifying factor of these techniques, allowing scientists to discover new historical sites or to …
Effect of saliva contamination on bracket failure with a self-etching primer: A prospective controlled clinical trial
2010
Introduction The aim of this study was to evaluate in vivo the effect of saliva contamination at different stages of the bonding procedure on the bond failure rate and the adhesive remaining on teeth after debonding brackets bonded with a hydrophilic self-etching primer (Transbond Plus self-etching primer [TSEP], 3M Unitek, Monrovia, Calif). Methods This was a prospective controlled clinical trial. The sample consisted of 46 patients with similar treatment plans and mechanotherapies. Stainless steel brackets (n = 531) were bonded with TSEP. The patients were divided into 2 groups: contamination with saliva before TSEP application and contamination with saliva after TSEP application. In both…
Effect of cyclic loading on fracture strength and microleakage of a quartz fiber dowel with different adhesive, cement and resin core material combin…
2010
Background: This study evaluated the performance of different adhesive-cement-core combinations coupled with quartz fiber dowels after cyclic loading and fracture strength tests and assessed the microleakage using dye penetration method. Methods: Forty maxillary canines (n=10 per group) were restored with fiber dowels (Quartz fiber DT Light Post) and four adhesive-cement-core material combinations [(Group 1: All-Bond 2+C&B (root) / All-Bond 2+Biscore (core); Group 2: All-Bond 2+Bisfil 2B (root) / All-Bond 2+Bisfil 2B (core); Group 3: Scotchbond 1+RelyX ARC (root) / Scotchbond 1+Supreme (core); Group 4: RelyX Unicem (root) / Scotchbond 1+Filtek Supreme (core)]. The specimens were initially c…
Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model
2021
Abstract Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files. Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the following study groups depending on the movements to be performed: ReFlex Dynamic (n = 10), ReFlex Smart (n = 10) and Reciproc (n = 10) reciprocating movement. These files were fixed to a specific dynamic cyclic fatigue device designed and manufactured by 3D impression to simulate the pecking motion performed by the operator. The time to failure and the number of cycles of in-and-out of the endodont…
CY5 fluorescence measured with silicon photomultipliers
2014
This paper presents an efficient optical biosensor set up for a low-level light detection, using fluorescent dyes and a novel Si-based detector. Fluorescence emitted by a traditional fluorophore, CY5, widely used as optical label in DNA microarrays, was detected using a 25 pixels Silicon photomultiplier (SiPM), a device formed by avalanche diodes operating in Geiger mode, in parallel connections. We measured the fluorescence current in different deposition (fluorophore concentration; solvent; salt concentration) and operation (angle of analysis, optical laser power, device gain) conditions. The characterization of DNA samples labeled with CY5 is also reported to demonstrate the detector pot…
Microbiological quality of carbonated drinking water produced with in-home carbonation systems.
2005
The microbiological quality of carbonated water produced with tap water in commercial in-home carbonation systems was determined, the results being discussed in the context of the microbiological quality of the tap water used, the properties of the drink makers, and the procedures of preparation and washing of various parts of the appliance. The last-mentioned data were received from each participant of the study by questionnaire. Escherichia coli, coliforms, fecal streptococci and spore-forming sulphite-reducing anaerobes were used as indicators for the hygienic quality of the water. Tap-water samples were collected according to the usual procedure when filling the carbonating bottle, i.e.…