Search results for "IPM"

showing 10 items of 1361 documents

Signal to Noise Ratio of Silicon Photomultipliers measured in the Continuous Wave Regime

2014

We performed a Signal to Noise Ratio characterization, in the continuous wave regime, at different bias voltages, frequencies and temperatures, on a novel class of silicon photomultipliers fabricated in planar technology on silicon p-type substrate. Signal to Noise Ratio has been measured as the ratio of the photogenerated current, filtered and averaged by a lock-in amplifier, and the Root Mean Square deviation of the overall current flowing to the device. The measured noise takes into account the shot noise, resulting from the photocurrent and the dark current. We have also performed a comparison between our SiPMs and a photomultiplier tube in terms of Signal to Noise Ratio, as a function …

Noise temperatureMaterials sciencePhysics::Instrumentation and Detectorsbusiness.industryphotomultipliers sipm snr detector siliconNoise spectral densityElectrical engineeringShot noiseSettore ING-INF/02 - Campi ElettromagneticiNoise figureNoise (electronics)Settore ING-INF/01 - ElettronicaSignal-to-noise ratioOpticsNoise generatorFlicker noisebusiness
researchProduct

Contrast-Enhanced Magnetic Resonance Angiography of the Pulmonary Vasculature

1998

Magnetic resonance angiography (MRA) has been established as a powerful noninvasive imaging modality. Its applications to the study of the pulmonary vasculature have been hampered by a multitude of factors, such as respiratory and cardiac motion artifacts, saturation problems, long acquisition times

Noninvasive imagingmedicine.medical_specialtygenetic structuresmedicine.diagnostic_testbusiness.industryGeneral Medicineequipment and suppliesMagnetic resonance angiographyCardiac motioncardiovascular systemmedicineRadiology Nuclear Medicine and imagingPulmonary vasculatureRadiologybusinesscirculatory and respiratory physiologyInvestigative Radiology
researchProduct

Supercontinuum optimization for dual-soliton based light sources using genetic algorithms in a grid platform

2014

We present a numerical strategy to design fiber based dual pulse light sources exhibiting two predefined spectral peaks in the anomalous group velocity dispersion regime. The frequency conversion is based on the soliton fission and soliton self-frequency shift occurring during super- continuum generation. The optimization process is carried out by a genetic algorithm that provides the optimum input pulse parameters: wavelength, temporal width and peak power. This algorithm is implemented in a Grid platform in order to take advantage of distributed computing. These results are useful for optical coherence tomography applications where bell-shaped pulses located in the second near-infrared wi…

Nonlinear opticsLightFOS: Physical sciencesSoliton (optics)Pulse propagation and temporal solitonsOpticsIllumination designOptical coherence tomographyGenetic algorithmmedicineCIENCIAS DE LA COMPUTACION E INTELIGENCIA ARTIFICIALFiber Optic TechnologyScattering RadiationComputer SimulationElectrodesPhysicsPhotonsmedicine.diagnostic_testOptical coherence tomographybusiness.industryNonlinear opticsEquipment DesignAtomic and Molecular Physics and OpticsSupercontinuumPulse (physics)Power (physics)WavelengthComputer-Aided DesignbusinessAlgorithmsOptics (physics.optics)Physics - Optics
researchProduct

A novel technique to follow fast PaO2 variations during experimental CPR

2003

An ultrafast responding fluorescent-quenching PO2 probe allows time-resolved, in vivo measurement of PO2. This study describes several validation experiments of this new device in vitro, and reports its first use during cardiopulmonary resuscitation in an animal model of cardiac arrest.The influence of CO2, temperature and motion artefacts on the signal response of the PO2 probe was analysed in vitro by systematic variation of these values. Thereafter, with approval of the Review Board for the care and use of animals, CPR was performed in four pigs. The PaO2 course was recorded continuously at time resolution of80 ms in the abdominal aorta using an uncoated fluorescence-quenching probe (Fox…

Novel techniquemedicine.medical_specialtySwineDefibrillationPartial Pressuremedicine.medical_treatmentEmergency NursingSignalAnimal modelIn vivoIntensive caremedicineAnimalsFiber Optic TechnologyCardiopulmonary resuscitationFluorescent Dyesbusiness.industryTemperatureTime resolutionEquipment DesignCarbon DioxideCardiopulmonary ResuscitationHeart ArrestSurgeryOxygenDisease Models AnimalEmergency MedicineArtifactsCardiology and Cardiovascular MedicinebusinessBiomedical engineering
researchProduct

From transition magnetic moments to majorana neutrino masses

2005

It is well known that a majorana mass induces a (small) transition magnetic moment. The converse is also true; in this paper we estimate the loop contribution of transition magnetic moments $[\mu]_{\alpha \beta}$ to the neutrino mass matrix $[m]_{\alpha \beta}$. We show that for hierarchical neutrino masses, the contribution of $[\mu]_{e \tau}$ to $[m]_{e \tau}$ can exceed the experimental value of $[m]_{e \tau}$.

Nuclear and High Energy PhysicsParticle physicsFOS: Physical sciences01 natural sciencesNuclear physicsHigh Energy Physics - Phenomenology (hep-ph)0103 physical sciencesmental disorders010306 general physicsM-matrixPhysicsMagnetic moment010308 nuclear & particles physicsHigh Energy Physics::PhenomenologyFísicaRenormalization groupMass matrixequipment and suppliesLoop (topology)MAJORANAHigh Energy Physics - Phenomenology[PHYS.HPHE]Physics [physics]/High Energy Physics - Phenomenology [hep-ph]NeutrinoMass hierarchyhuman activities
researchProduct

Future Physics Programme of BESIII

2020

There has recently been a dramatic renewal of interest in the subjects of hadron spectroscopy and charm physics. This renaissance has been driven in part by the discovery of a plethora of charmonium-like $XYZ$ states at BESIII and $B$ factories, and the observation of an intriguing proton-antiproton threshold enhancement and the possibly related $X(1835)$ meson state at BESIII, as well as the threshold measurements of charm mesons and charm baryons. We present a detailed survey of the important topics in tau-charm physics and hadron physics that can be further explored at BESIII over the remaining lifetime of BEPCII operation. This survey will help in the optimization of the data-taking pla…

Nuclear and High Energy PhysicsParticle physicsX(1835)charmed mesonMesoncharmoniumNuclear TheoryFOS: Physical sciences7. Clean energy01 natural sciencesHigh Energy Physics - ExperimentNOSubatomär fysikHigh Energy Physics - Experiment (hep-ex)High Energy Physics - Phenomenology (hep-ph)Hadron physicsHadron spectroscopySubatomic Physics0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]ddc:530Charm (quantum number)charmed baryontau010306 general physicsNuclear ExperimentInstrumentationanti-p pactivity reportPhysicsthreshold: enhancementLuminosity (scattering theory)BES010308 nuclear & particles physicshadron spectroscopyHigh Energy Physics::PhenomenologyThe RenaissanceAstronomy and AstrophysicsBeijing Stor: upgradeBaryonHigh Energy Physics - PhenomenologyUpgradeexperimental equipment[PHYS.HPHE]Physics [physics]/High Energy Physics - Phenomenology [hep-ph]High Energy Physics::Experimentluminosity: high
researchProduct

Results on radiation hardness of black silicon induced junction photodetectors from proton and electron radiation

2020

Abstract The stability of black silicon induced junction photodetectors under high-energy irradiation was tested with 11 MeV protons and 12 MeV electrons using fluence of 1 ⋅ 10 10 protons/cm2 and dose of 67 krad(Si) for protons and electrons, respectively. The energies and dose levels were selected to test radiation levels relevant for space applications. The degradation was evaluated through dark current and external quantum efficiency changes during (within 1 h after each step) and after (some days after) full irradiation sequences. Furthermore, the black silicon photodetectors were compared to planar silicon induced junction and planar silicon pn-junction photodetectors to assess the co…

Nuclear and High Energy PhysicsPassivationSiliconPhysics::Instrumentation and Detectorschemistry.chemical_element02 engineering and technology01 natural scienceschemistry.chemical_compound0103 physical sciencesRadiation damageElectron beam processingIrradiationInstrumentationPhysics010308 nuclear & particles physicsbusiness.industryBlack silicontechnology industry and agricultureequipment and supplies021001 nanoscience & nanotechnologySemiconductorchemistryOptoelectronicsQuantum efficiency0210 nano-technologybusinessNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Detector characterization and first coincidence tests of a Compton telescope based on LaBr3 crystals and SiPMs

2011

International audience; A Compton telescope for dose monitoring in hadron therapy consisting of several layers of continuous LaBr3 crystals coupled to silicon photomultiplier (SiPM) arrays is under development within the ENVISION project. In order to test the possibility of employing such detectors for the telescope, a detector head consisting of a continuous 16 mm×18 mm×5 mm LaBr3 crystal coupled to a SiPM array has been assembled and characterized, employing the SPIROC1 ASIC as readout electronics. The best energy resolution obtained at 511 keV is 6.5% FWHM and the timing resolution is 3.1 ns FWHM. A position determination method for continuous crystals is being tested, with promising res…

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsCompton telescopeSiPM01 natural sciences7. Clean energyCoincidence030218 nuclear medicine & medical imaginglaw.inventionTelescope03 medical and health sciencesHadron therapy0302 clinical medicineOpticsSilicon photomultiplierApplication-specific integrated circuitlaw0103 physical sciencesCompton imaging[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det][SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsInstrumentationPhysicsContinuous crystal010308 nuclear & particles physicsbusiness.industryResolution (electron density)DetectorMPPCG-APDLaBr3Full width at half maximumbusiness
researchProduct

High resolution detectors based on continuous crystals and SiPMs for small animal PET

2012

International audience; Sensitivity and spatial resolution are the two main factors to maximize in emission imaging. The improvement of one factor deteriorates the other with pixelated crystals. In this work we combine SiPM matrices with monolithic crystals, using an accurate γ-ray interaction position determination algorithm that provides depth of interaction. Continuous crystals provide higher sensitivity than pixelated crystals, while an accurate interaction position determination does not degrade the spatial resolution. Monte Carlo simulations and experimental data show good agreement both demonstrating sub-millimetre intrinsic spatial resolution. A system consisting in two rotating det…

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsSiPMMonte Carlo methodHigh resolution01 natural sciencesCoincidence030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplierPosition (vector)0103 physical sciencesHigh resolutionSensitivity (control systems)[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det][SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsInstrumentationImage resolutionPhysics010308 nuclear & particles physicsbusiness.industryDetectorPosition determinationPETMonolithic crystalsbusiness
researchProduct

Heavy-Ion Induced Charge Yield in MOSFETs

2009

The heavy-ion induced electron/hole charge yield in silicon-oxide versus electric field is presented. The heavy-ion charge yield was determined by comparing the voltage shifts of MOSFET transistors irradiated with 10-keV X-rays and several different heavy ions. The obtained charge yield for the heavy ions is in average nearly an order of magnitude lower than for the X-rays for the entire range of measured electric fields.

Nuclear and High Energy PhysicsRange (particle radiation)Yield (engineering)Materials scienceAstrophysics::High Energy Astrophysical PhenomenaCharge (physics)Electronequipment and suppliesIonNuclear Energy and EngineeringElectric fieldMOSFETElectrical and Electronic EngineeringAtomic physicsVoltageIEEE Transactions on Nuclear Science
researchProduct