Search results for "IRRADIANCE"
showing 10 items of 152 documents
A Preliminary Estimation of the Direct Ultraviolet Spectral Irradiance in Valencia (Spain): Comparison with Measured Values
2000
UVSPEC and SMARTS2 models have been used to estimate the UV spectral irradiance values in Valencia, Spain, and the results of these estimations have been compared with experimental measurements of direct irradiance at normal incidence obtained using an Optronic OL 754 in the 300-400 nm range. The relative RMSD and MBD parameters have been used to estimate the deviations of the modelled values with respect to the experimental values. The results indicate that the deviations are smaller when the SMARTS2 model is used with the appropriate aerosol coefficients.
A comparison of different one-diode models for the representation of I–V characteristic of a PV cell
2014
Predictive performance tools are an important factor in the success of any new technology because they permit demonstration of whether a system will be efficient and economically feasible. A reliable predictive tool should allow the designer to optimise system performance and to maximise the cost effectiveness of a system prior to installation. This article discusses the five main parametric models for photovoltaic (PV) systems available in the literature. The current–voltage characteristics of a photovoltaic module can be reproduced modelling the PV panel as an equivalent electrical circuit made of linear and non-linear components. The parameters describing such components are directly rel…
Thermal–infrared emissivities of natural surfaces: improvements on the experimental set-up and new measurements
2003
Ground measurements of thermal infrared emissivities of terrestrial surfaces are required to derive accurate temperatures from radiometric measurements, and also to apply and validate emissivity models using satellite sensor observations. This paper focuses on the demanding aspects that are involved in the field measurement of emissivity using the box method and a hand-held radiometer. Measuring emissivities in field conditions can be hampered by external factors such as wind and solar irradiance. This can increase the time spent on the field campaign but, most importantly, it can cause no-sense fluctuations between consecutive observations. Here we propose original developments for the exp…
Stability of the performance of thin film modules during one year of operation
2012
At the University of Agder in Grimstad, Southern Norway, a test bench for photovoltaic modules is in operation since December 2010. Currently, various c-Si as well as aSi, CIS and HIT modules are under investigation. This project is part of the Norwegian contribution to IEA PVPS Task13. The paper focuses on the stability of the modules' MPP-performance in the course of one year. For this purpose, data on the DC response are logged together with irradiance and module temperature at one-minute intervals. Data analysis is performed in monthly blocks. The modeling involves two steps. First, the short-circuit current is expressed as function of irradiance and module temperature. Then, the MPP po…
Planktothrix rubescens in freshwater reservoirs: remote sensing potentiality for mapping cell density
2012
Planktothrix rubescens is sadly famous for producing microcystins (MCs), which are powerful hepatotoxins. During the winter 2005/06, P. rubescens has been found in the Pozzillo, Nicoletti, Prizzi and Garcia reservoirs, Sicily; in 2008 it was also detected in SS. Trinita di Delia and Castello reservoirs. Indeed, during periods of low shortwave irradiance such as winter, when light weakly penetrates water column and the water cools, P. rubescens filaments float up to the surface, forming red-colored blooms. Ancillary meteorological measurements highlighted low air temperatures between two frosts in December 2007 and February 2008, with a simultaneous reduction in the incoming total solar radi…
Indoor lighting quality: Effects of different wall colours
2016
This paper reports the results of measurements performed in a test room to investigate the impact of using different wall colours and light scenes on indoor lighting quality. Eye level spectral irradiances were measured for a user located inside the room and seated at a desk. These measurements allow the use of the Irradiance Toolbox, which makes it possible to calculate equivalent illuminances for the photopigments in the human eye. Moreover, the CIECAM02 colour appearance model was used to investigate the variations in hue and chroma values of the different wall colours when changing the light scene. The results demonstrate that there are significant variations in eye level spectral irra…
Apparato di commutazione
2012
La presente invenzione si riferisce ad un apparato di commutazione per il controllo e l'impostazione della configurazione circuitale dei pannelli di un modulo fotovoltaico.
Rateless Codes Performance Analysis in Correlated Channel Model for GEO Free Space Optics Downlinks
2012
On the experimental validation of an improved five-parameter model for silicon photovoltaic modules
2012
Abstract This paper presents the experimental validation of a new five-parameter model capable of analytically describing the I–V characteristic of a silicon photovoltaic module for each generic condition of operative temperature and solar irradiance. The operating current calculated with the model was validated on the basis of a series of experimental measurements performed in the field on two commercial silicon photovoltaic panels connected to a set of nine constant values of the electrical load. In order to examine the panels working in almost steady-state conditions only the data-sets of the sunniest days from sunrise to sunset were used. Unfortunately the production spread of photovolt…
Quantifying residential PV feed-in power in low voltage grids based on satellite-derived irradiance data with application to power flow calculations
2016
AbstractA scheme using satellite-derived irradiance measurements to model the feed-in power of residential photovoltaic (PV) systems in a low voltage distribution grid is described. It is validated against smart meter measurements from a test site with 12 residential PV systems in the city of Ulm, Germany, during May 2013 to December 2014. The PV feed-in power is simulated in a 15-min time resolution based on irradiance data derived from Meteosat Second Generation satellite images by the physically based retrieval scheme Heliosat-4. The PV simulation is based on the nominal power and location of the PV systems as provided by the distribution system operator. Orientation angles are taken fro…