Search results for "Image Enhancement"

showing 10 items of 215 documents

Systematic review of the diagnosis of gastric premalignant conditions and neoplasia with high-resolution endoscopic technologies

2013

Aim. The aim of the article is to systematically review the current evidence on the diagnostic use of narrow band imaging (NBI), flexible spectral imaging color enhancement (FICE) and endoscopic image enhancement technology i-scan endoscopies for gastric precancerous and cancerous lesions. Materials and methods. Original manuscripts were searched in PubMed until October 2012. Pertinent data were collected and pooled diagnostic accuracy measures were estimated when possible. Results. In total, 38 studies were evaluated. Thirty-one studies were included for NBI and 7 studies for FICE assessment in this systematic review. No article was found meeting inclusion criteria for i-scan endoscopy. Th…

medicine.medical_specialtyHigh resolutionAdenocarcinomaSensitivity and SpecificityGastroenterologyNarrow Band ImagingStomach NeoplasmsInternal medicineGastroscopymedicineHumansObserver VariationModels StatisticalNarrow-band imagingmedicine.diagnostic_testbusiness.industryGastroenterologyReproducibility of ResultsIntestinal metaplasiaImage Enhancementmedicine.diseaseEndoscopyGastric MucosaDysplasiaColor enhancementDiagnostic odds ratioRadiologybusinessPrecancerous ConditionsEndoscopic imageScandinavian Journal of Gastroenterology
researchProduct

Multimodality 3-dimensional volumetric ultrasound in obstetrics and gynecology with an emphasis in HDlive technique.

2013

HDlive (high-definition live or real-time US), a new ultrasound software, combines a movable virtual adjustable light source in a software that calculates the proportion of light reflecting through surface structures, depending on light direction. The light source can be manually positioned to illuminate the desired area of interest. The ultrasound technician can control light intensity to create shadows that enhance image quality. HDlive is an innovation that will render even more realistic images of fetal anatomy and of gynecologic lesions. The full potential of this new technology is yet to be determined and deserves scientific evaluation.

medicine.medical_specialtyImage qualityMultimodal ImagingMultimodalitySoftwareLight sourceObstetrics and gynaecologyComputer SystemsPregnancyImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingComputer visionDiagnostic Techniques Obstetrical and GynecologicalUltrasonographybusiness.industryEmphasis (telecommunications)UltrasoundImage EnhancementObstetric Labor ComplicationsLight intensityFemaleRadiologyArtificial intelligencebusinessGenital Diseases FemaleSoftwareUltrasound quarterly
researchProduct

Undetected Malignancies of the Breast: Dynamic Contrast-enhanced MR Imaging at 1.0 T

2002

To assess the prevalence and characteristics of malignant breast lesions not identified with magnetic resonance (MR) imaging.Breast tissue specimens were obtained in 464 of 967 patients who had undergone dynamic gadolinium-enhanced T1-weighted fast low-angle shot three-dimensional MR imaging of both breasts. A comparison of sensitivity, specificity, and predictive values of the prospectively recorded findings of mammography, ultrasonography (US), and MR imaging with the histopathologic results was performed with receiver operating characteristic (ROC) curve analysis. MR imaging examination findings that caused a false-negative diagnosis were reviewed to identify possible sources of error.Hi…

medicine.medical_specialtyMammary glandBreast NeoplasmsGadoliniumSensitivity and SpecificityPredictive Value of TestsmedicineHumansMammographyRadiology Nuclear Medicine and imagingmedicine.diagnostic_testReceiver operating characteristicbusiness.industryCurve analysisMagnetic resonance imagingImage EnhancementMagnetic Resonance ImagingMr imagingDynamic contrastmedicine.anatomical_structureROC CurveFemaleHistopathologyUltrasonography MammaryRadiologyArtifactsNuclear medicinebusinessRadiology
researchProduct

Graph-matching based CTA.

2009

Separating bone, calcification, and vessels in computer tomography angiography (CTA) allows for a detailed diagnosis of vessel stenosis. This paper presents a new, graph-based technique that solves this difficult problem with high accuracy. The approach requires one native data set and one that is contrast enhanced. On each data set, an attributed level-graph is derived and both graphs are matched by dynamic programming to differentiate between bone, on one hand side, and vessel/calcification on the other hand side. Lumen and calcified regions are then separated by a profile technique. Evaluation is based on data from vessels of pelvis and lower extremities of elderly patients. Due to subst…

medicine.medical_specialtyMatching (graph theory)Computer scienceComputed tomographySensitivity and SpecificityPattern Recognition AutomatedArtificial IntelligencemedicineHumansSegmentationElectrical and Electronic EngineeringPelvisPeripheral Vascular DiseasesRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryAngiographyReproducibility of ResultsPattern recognitionNumerical Analysis Computer-AssistedImage segmentationmedicine.diseaseComputer Science ApplicationsRadiographic Image EnhancementStenosismedicine.anatomical_structureSubtraction TechniqueAngiographyRadiographic Image Interpretation Computer-AssistedRadiologyTomographyArtificial intelligencebusinessTomography X-Ray ComputedSoftwareAlgorithmsCalcificationIEEE transactions on medical imaging
researchProduct

VITOM® 3D system in surgeon microsurgical vascular training: our model and experience.

2017

LETTER TO EDITOR

medicine.medical_specialtyMicrosurgerySurgical trainingMini-invasive surgeryMEDLINESettore MED/22 - Chirurgia Vascolare03 medical and health sciences0302 clinical medicineArteriovenous Shunt SurgicalArterio-venous fistula; Mini-invasive surgery; Surgical trainingMedicineHumansSaphenous Vein030223 otorhinolaryngologySurgical instrumentationbusiness.industryGeneral surgerySuture TechniquesInternship and ResidencyEquipment DesignImage EnhancementArterio-venous fistulaSurgerySettore MED/18 - Chirurgia GeneraleNephrologyEducation Medical Graduate030220 oncology & carcinogenesisSurgeryEducation Medical ContinuingSurgical educationClinical CompetenceClinical competencebusinessLearning CurveThe journal of vascular access
researchProduct

Mosaic architecture of hepatocellular carcinoma

2017

medicine.medical_specialtyPathologyCarcinoma HepatocellularHepatocellular carcinomaUrologyContrast MediaMosaic (geodemography)030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineInternal medicineCarcinomamedicineHumansRadiology Nuclear Medicine and imagingRadiological and Ultrasound Technologybusiness.industryLiver NeoplasmsGastroenterologyHepatologyImage Enhancementmedicine.diseaseMagnetic Resonance ImagingLiver030220 oncology & carcinogenesisHepatocellular carcinomaTomography X-Ray Computedbusiness
researchProduct

Quantitative magnetic resonance imaging for focal liver lesions: bridging the gap between research and clinical practice

2021

Magnetic resonance imaging (MRI) is highly important for the detection, characterization, and follow-up of focal liver lesions. Several quantitative MRI-based methods have been proposed in addition to qualitative imaging interpretation to improve the diagnostic work-up and prognostics in patients with focal liver lesions. This includes DWI with apparent diffusion coefficient measurements, intravoxel incoherent motion, perfusion imaging, MR elastography, and radiomics. Multiple research studies have reported promising results with quantitative MRI methods in various clinical settings. Nevertheless, applications in everyday clinical practice are limited. This review describes the basic princ…

medicine.medical_specialtyQuantitative magnetic resonance imagingContrast MediaPerfusion scanningReview Article030218 nuclear medicine & medical imaging03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineImage Interpretation Computer-AssistedmedicineHumansEffective diffusion coefficientRadiology Nuclear Medicine and imagingIn patientIntravoxel incoherent motionRadiomicsmedicine.diagnostic_testbusiness.industryLiver NeoplasmsMagnetic resonance imagingGeneral MedicinePerfusion imagingImage EnhancementPrognosisMagnetic Resonance ImagingClinical PracticeDiffusion Magnetic Resonance Imaging030220 oncology & carcinogenesisElasticity Imaging TechniquesDiffusion-weighted imagingRadiologyElastographyElastographySettore MED/36 - Diagnostica Per Immagini E RadioterapiabusinessThe British Journal of Radiology
researchProduct

Contrast-Enhanced Ultrasound in Focal Liver Lesions: Where Do We Stand?

2016

Contrast-enhanced ultrasound (CEUS) represents a significant breakthrough in sonography, and it is being increasingly used for the evaluation of focal liver lesions (FLLs). Currently, CEUS is included as a part of the suggested diagnostic workup of FLLs, resulting in a better patient management and delivering cost-effective therapy. After a brief technical note, contrast-enhancement patterns of different types of benign and malignant FLLs, along with hepatic pseudolesions, are described and discussed based on our experience and literature data. At the same time, the most recent concepts and the use of CEUS in different clinical settings are presented.

medicine.medical_specialtyRadiology Nuclear Medicine and ImagingMEDLINEContrast MediaClinical settingsSensitivity and Specificity030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineText miningmedicineHumansUltrasonographybusiness.industryLiver DiseasesLiver DiseaseUltrasoundTechnical noteImage EnhancementPatient management030211 gastroenterology & hepatologyRadiologybusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaContrast-enhanced ultrasoundHuman
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct

Implant-specific follow-up imaging of treated intracranial aneurysms: TOF-MRA vs. metal artifact reduced intravenous flat panel computed tomography a…

2017

Aim To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. Methods The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n= 20; clipping: n= 15; coiling + stenting: n= 9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-ima…

medicine.medical_specialtyWilcoxon signed-rank testImage qualityComputed Tomography Angiographymedicine.medical_treatmentContrast MediaMagnetic resonance angiography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineAneurysmMcNemar's testmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesComputed tomography angiographyRetrospective Studiesmedicine.diagnostic_testbusiness.industryIntracranial AneurysmGeneral MedicineClipping (medicine)Prostheses and Implantsmedicine.diseaseImage EnhancementSurgical InstrumentsCerebral AngiographyMetalscardiovascular systemStentsImplantRadiologybusinessArtifacts030217 neurology & neurosurgeryMagnetic Resonance AngiographyFollow-Up StudiesClinical radiology
researchProduct