Search results for "Image enhancement"
showing 10 items of 215 documents
Superresolved digital in-line holographic microscopy for high-resolution lensless biological imaging.
2010
Digital in-line holographic microscopy (DIHM) is a modern approach capable of achieving micron-range lateral and depth resolutions in three-dimensional imaging. DIHM in combination with numerical imaging reconstruction uses an extremely simplified setup while retaining the advantages provided by holography with enhanced capabilities derived from algorithmic digital processing. We introduce superresolved DIHM incoming from time and angular multiplexing of the sample spatial frequency information and yielding in the generation of a synthetic aperture (SA). The SA expands the cutoff frequency of the imaging system, allowing submicron resolutions in both transversal and axial directions. The pr…
Surpassing digital holography limits by lensless object scanning holography.
2012
We present lensless object scanning holography (LOSH) as a fully lensless method, capable of improving image quality in reflective digital Fourier holography, by means of an extremely simplified experimental setup. LOSH is based on the recording and digital post-processing of a set of digital lensless holograms and results in a synthetic image with improved resolution, field of view (FOV), signal-to-noise ratio (SNR), and depth of field (DOF). The superresolution (SR) effect arises from the generation of a synthetic aperture (SA) based on the linear movement of the inspected object. The same scanning principle enlarges the object FOV. SNR enhancement is achieved by speckle suppression and c…
Can ECG-gated MDCT be considered an obligatory step to plan and manage a new chest-pain unit?
2007
The recent improvements in multi-detector computed tomography technology and its application in cardiac field allow to consider this non-invasive imaging technique as a promising comprehensive method for detecting significant coronary stenoses in a chest-pain unit. The possibility to use the ECG-synchronisation acquisition protocol, normally limited to the cardiac volume, for the entire thoracic vascular system should have the remarkable potential to reduce invasive and non-invasive procedures actually used to investigate acute chest pain and the number of unnecessary hospital admissions without reducing appropriate admissions in patients with chest pain.
Comprehensive cardiovascular ECG-gated MDCT as a standard diagnostic tool in patients with acute chest pain
2007
Acute myocardial infarction, pulmonary embolism, and aortic dissection are diseases associated with acute chest pain and may lead to severe morbidity and mortality. These diseases may not be trivial to diagnose in the settings of emergency room. ECG-gated multi-detector computed tomography (MDCT), already established for the assessment of pulmonary embolism and aortic dissection, provides reliable information regarding the triage of patients with acute coronary syndrome in the emergency room. MDCT recently appeared to be logistically feasible and a promising comprehensive method for the evaluation of cardiac and non-cardiac chest pain in emergency department patients. The possibility to sca…
Pervasive access to MRI bias artifact suppression service on a grid.
2009
Bias artifact corrupts magnetic resonance images in such a way that the image is afflicted by illumination variations. Some of the authors proposed the Exponential Entropy Driven - Homomorphic Unsharp Masking (E2D-HUM) algorithm that corrects this artifact without any a priori hypothesis about the tissues or the Magnetic Resonance image modality. Moreover, E2D-HUM does not care about the body part under examination and does not require any particular training task. People who want to use this algorithm, which is Matlab-based, have to set their own computers in order to execute it. Furthermore, they have to be Matlab-skilled to exploit all the features of the algorithm. In our work we propos…
Image Content Enhancement Through Salient Regions Segmentation for People With Color Vision Deficiencies
2019
Color vision deficiencies affect visual perception of colors and, more generally, color images. Several sciences such as genetics, biology, medicine, and computer vision are involved in studying and analyzing vision deficiencies. As we know from visual saliency findings, human visual system tends to fix some specific points and regions of the image in the first seconds of observation summing up the most important and meaningful parts of the scene. In this article, we provide some studies about human visual system behavior differences between normal and color vision-deficient visual systems. We eye-tracked the human fixations in first 3 seconds of observation of color images to build real f…
Inverse Tone Mapping Based upon Retina Response
2014
International audience; The development of high dynamic range (HDR) display arouses the research of inverse tone mapping methods, which expand dynamic range of the low dynamic range (LDR) image to match that of HDR monitor. This paper proposed a novel physiological approach, which could avoid artifacts occurred in most existing algorithms. Inspired by the property of the human visual system (HVS), this dynamic range expansion scheme performs with a low computational complexity and a limited number of parameters and obtains high-quality HDR results. Comparisons with three recent algorithms in the literature also show that the proposed method reveals more important image details and produces …
Improved Estimation of Cardiac Function Parameters Using a Combination of Independent Automated Segmentation Results in Cardiovascular Magnetic Reson…
2015
International audience; This work aimed at combining different segmentation approaches to produce a robust and accurate segmentation result. Three to five segmentation results of the left ventricle were combined using the STAPLE algorithm and the reliability of the resulting segmentation was evaluated in comparison with the result of each individual segmentation method. This comparison was performed using a supervised approach based on a reference method. Then, we used an unsupervised statistical evaluation, the extended Regression Without Truth (eRWT) that ranks different methods according to their accuracy in estimating a specific bio-marker in a population. The segmentation accuracy was …
Three-dimensional object detection under arbitrary lighting conditions
2006
A novel method of 3D object recognition independent of lighting conditions is presented. The recognition model is based on a vector space representation using an orthonormal basis generated by the Lambertian reflectance functions obtained with distant light sources. Changing the lighting conditions corresponds to multiplying the elementary images by a constant factor and because of that, all possible lighting views will be elements that belong to that vector space. The recognition method proposed is based on the calculation of the angle between the vector associated with a certain illuminated 3D object and that subspace. We define the angle in terms of linear correlations to get shift and i…
Directionlets: Anisotropic Multidirectional representation with separable filtering
2006
In spite of the success of the standard wavelet transform (WT) in image processing in recent years, the efficiency of its representation is limited by the spatial isotropy of its basis functions built in the horizontal and vertical directions. One-dimensional (1-D) discontinuities in images (edges and contours) that are very important elements in visual perception, intersect too many wavelet basis functions and lead to a nonsparse representation. To efficiently capture these anisotropic geometrical structures characterized by many more than the horizontal and vertical directions, a more complex multidirectional (M-DIR) and anisotropic transform is required. We present a new lattice-based pe…