Common-path phase-shifting digital holographic microscopy: A way to quantitative phase imaging and superresolution
2008
We present an experimental setup useful for complex amplitude evaluation and phase image quantification of three-dimensional (3-D) samples in digital holographic microscopy (DHM). It is based on a common-path interferometric configuration performed by dividing the input plane in two contiguous regions and by placing a translation grating near to the Fourier plane. Then, complex amplitude distribution of the sample under test is recovered with phase-shifting standard method obtained by moving the grating using a linear motion stage. Some experimental results of an USAF resolution test are presented for different numerical aperture (NA) microscope lenses. In a second part, the proposed setup …
2017
Micro-fluidic pumps as well as artificial micro-swimmers are conveniently realized exploiting phoretic solvent flows based on local gradients of temperature, electrolyte concentration or pH. We here present a facile micro-photometric method for monitoring pH gradients and demonstrate its performance and scope on different experimental situations including an electro-osmotic pump and modular micro-swimmers assembled from ion exchange resin beads and polystyrene colloids. In combination with the present microscope and DSLR camera our method offers a 2 \mu m spatial resolution at video frame rate over a field of view of 3920x2602 \mu m^2. Under optimal conditions we achieve a pH-resolution of …
Resolution improvements in integral microscopy with Fourier plane recording
2016
Abstract: Integral microscopes (IMic) have been recently developed in order to capture the spatial and the angular information of 3D microscopic samples with a single exposure. Computational post-processing of this information permits to carry out a 3D reconstruction of the sample. By applying conventional algorithms, both depth and also view reconstructions are possible. However, the main drawback of IMic is that the resolution of the reconstructed images is low and axially heterogeneous. In this paper, we propose a new configuration of the IMic by placing the lens array not at the image plane, but at the pupil (or Fourier) plane of the microscope objective. With this novel system, the spa…
Filter performance parameters for vectorial high-aperture wave fields.
2008
Performance parameters have been presented that can be used to compare the focusing performance of different optical systems, including the effect of pupil filters. These were originally given for the paraxial case and recently extended to the high-aperture scalar regime. We generalize these parameters to the full vectorial case for an aplanatic optical system illuminated by a plane-polarized wave. The behavior of different optical systems is compared.
Monolithic focused reference beam x-ray holography
2013
Fourier transform holography is a highly efficient and robust imaging method, suitable for single-shot imaging at coherent X-ray sources. In its common implementation, the image contrast is limited by the reference signal generated by a small pinhole aperture. Increased pinhole diameters improve the signal, whereas the resolution is diminished. Here we report a new concept to decouple the spatial resolution from the image contrast by employing a Fresnel zone plate to provide the reference beam. Superimposed on-axis images of distinct foci are separated with a novel algorithm. Our method is insensitive to mechanical drift or vibrations and allows for long integration times common at low-flux…
Silicon as an Unconventional Detector in Positron Emission Tomography.
2012
Positron emission tomography (PET) is a widely used technique in medical imaging and in studying small animal models of human disease. In the conventional approach, the 511 keV annihilation photons emitted from a patient or small animal are detected by a ring of scintillators such as LYSO read out by arrays of photodetectors. Although this has been a successful in achieving ~5mm FWHM spatial resolution in human studies and ~1mm resolution in dedicated small animal instruments, there is interest in significantly improving these figures. Silicon, although its stopping power is modest for 511 keV photons, offers a number of potential advantages over more conventional approaches. Foremost is it…
The horizontal drift chambers for the focal plane proton-polarimeter of the 3-spectrometer setup at MAMI
2002
Abstract Large-area horizontal drift chambers have been built for use in a proton polarimeter. A gas mixture of 20% argon and 80% ethane is used. The left–right assignment is achieved by measuring the difference of the signals induced on neighboring potential wires. A spatial resolution of 300 μm is achieved.
A cylindrical GEM detector with analog readout for the BESIII experiment
2016
Abstract A cylindrical GEM detector with analog readout is under development for the upgrade of the Inner Tracker of the BESIII experiment at IHEP (Beijing). The new detector will match the requirements for momentum resolution ( σ pt / p t ~ 0.5 % at 1 GeV) and radial resolution ( σ xy ~ 120 μ m ) of the existing drift chamber and will improve significantly the spatial resolution along the beam direction ( σ z ~ 150 μ m ) with very small material budget (less than 1.5% of X 0 ). With respect to the state of the art the following innovations will be deployed: a lighter mechanical structure based on Rohacell, a new XV anode readout plane with jagged strip layout to reduce the parasitic capaci…
Scintillating fiber detectors for the HypHI project at GSI
2009
WOS: 000270326800009
Performance of the ATLAS silicon strip detector modules
1998
Abstract The performance of the silicon strip detector prototypes developed for use in ATLAS at the LHC is reported. Baseline detector assemblies (“modules”) of 12 cm length were read out with binary electronics at 40 MHz clock speed. For both irradiated and unirradiated modules, the tracking efficiency, noise occupancy, and position resolution were measured as a function of bias voltage, binary hit threshold, and detector rotation angle in a 1.56 T magnetic field. Measurements were also performed at a particle flux comparable to the one expected at the LHC.