Search results for "Image."
showing 10 items of 6790 documents
Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths
2016
The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…
Reference Ranges and Distribution of Placental Volume by 3-Dimensional Virtual Organ Computer-Aided Analysis Between 11 Weeks and 13 Weeks 6 Days
2013
OBJECTIVES The purpose of this study was to determine the feasibility, reproducibility, and distribution of placental volume measurements according to the crown-rump length between 11 weeks and 13 weeks 6 days. METHODS Images were acquired in 128 pregnancies followed in Burgundy during first-trimester screening sonography using an abdominal 3-dimensional transducer. The placental volume was then calculated by the virtual organ computer-aided analysis method with a rotation angle of 30° by a single operator. RESULTS Placental volumes ranged from 33.3 to 107.6 cm(3) with a mean ± SD of 62.3 ± 14.8 cm(3); the 5th and 10th percentiles were 38.0 and 44.20 cm(3), respectively, whereas the 90th an…
Differences in the nature of body image disturbances between female obese individuals with versus without a comorbid binge eating disorder: an explor…
2011
Various components of body image were measured to assess body image disturbances in patients with obesity. To overcome limitations of previous studies, a photo distortion technique and a biological motion distortion device were included to assess static and dynamic aspects of body image. Questionnaires assessed cognitive-affective aspects, bodily attitudes, and eating behavior. Patients with obesity and a binge eating disorder (OBE, n = 15) were compared with patients with obesity only (ONB; n = 15), to determine the nature of any differences in body image disturbances. Both groups had high levels of body image disturbances with cognitive-affective deficits. Binge eating disorder (BED) par…
Sexual self-schema: a cognitive schema and its relationship to choice of contraceptive method among Polish women
2019
Objectives: The aim of the study was to examine sexual self-schema in women using different methods of contraception. Methods: Women (N = 560) aged 18–55 years were divided into two groups: those who used hormonal contraception (n = 285) and those who used non-hormonal contraception (n = 275). Participants were assessed using the Sexual Self-Schema Scale (SSSS), the Well-Matched Marriage Questionnaire and the Hospital Anxiety and Depression Scale and were also asked to fill in a structured questionnaire, giving information on their socioeconomic status, reproductive and medical history, sexual behaviours, psychosexual orientation, sexual experience and type of contraception used. Results: W…
Temporal Structure of Human Gaze Dynamics Is Invariant During Free Viewing.
2015
We investigate the dynamic structure of human gaze and present an experimental study of the frequency components of the change in gaze position over time during free viewing of computer-generated fractal images. We show that changes in gaze position are scale-invariant in time with statistical properties that are characteristic of a random walk process. We quantify and track changes in the temporal structure using a well-defined scaling parameter called the Hurst exponent, H. We find H is robust regardless of the spatial complexity generated by the fractal images. In addition, we find the Hurst exponent is invariant across all participants, including those with distinct changes to higher or…
Simulating Images Seen by Patients with Inhomogeneous Sensitivity Losses
2012
PURPOSE We aim to simulate how colored images are perceived by subjects with local achromatic and chromatic contrast sensitivity losses in the visual field (VF). METHODS The spatiochromatic corresponding pair algorithm, introduced in a previous article (J Opt Soc Am (A) 2004;21:176-186), has been implemented with a linear model of the visual system. Spatial information is processed separately by the chromatic and achromatic mechanisms by means of a multiscale model, with sensors selective to frequency, orientation, and spatial position, whose mechanism-dependent relative weights change with the spatial location of the image. These weights have been obtained from perimetric data from a patie…
Automatic Detection of Left Ventricular Contours from Cardiac Cine Magnetic Resonance Imaging Using Fuzzy Logic
1999
Gated cardiac cine magnetic resonance imaging provides accurate dynamic data of the left ventricular function. However, the manual extraction of important physiologic parameters such as myocardium wall thickness and left ventricular volumes is invariably time consuming and subjective. To reduce the variability and time constraints inherent in observer contour tracing, the authors developed an automatic left ventricle contour-detection method.The purpose was to apply fuzzy logic-based automatic contour detection to identification of endocardial and epicardial borders in short-axis magnetic resonance images. The automatic contouring was compared with manual tracing using the calculated ejecti…
Automatic determination of aortic compliance with cine-magnetic resonance imaging - An application of fuzzy logic theory
2002
International audience; Abstract: RATIONALE AND OBJECTIVES. Aortic compliance is defined as the relative change in aortic cross-sectional area divided by the change in arterial pressure. Magnetic resonance imaging (MRI) is a useful imaging modality for the noninvasive evaluation of aortic compliance. However, manual tracing of the aortic contour is subject to important interobserver variations. To estimate the aortic compliance from cine-MRI, a method based on fuzzy logic theory was elaborated. MATERIALS AND METHODS. Seven healthy volunteers and eight patients with Marfan syndrome were examined using an ECG gated cine-MRI sequence. The aorta was imaged in the transverse plane at the level o…
Effectiveness of cognitive behavioral therapy supported by virtual reality in the treatment of body image in eating disorders: One year follow-up
2013
Body image disturbance is a significant maintenance and prognosis factor in eating disorders. Hence, existing eating disorder treatments can benefit from direct intervention in patients' body image. No controlled studies have yet compared eating disorder treatments with and without a treatment component centered on body image. This paper includes a controlled study comparing Cognitive Behavioral Treatment (CBT) for eating disorders with and without a component for body image treatment using Virtual Reality techniques. Thirty-four participants diagnosed with eating disorders were evaluated and treated. The clinical improvement was analyzed from statistical and clinical points of view. Result…
The internal calcar septum and its contact with the virtual stem in THR: a computer tomographic evaluation.
2003
The internal calcar septum is a ridge of cortical bone protruding from the inner cortical wall of the proximal femur into the medullary canal. It extends from the lesser trochanter into the femoral neck and narrows the femoral cavity in its dorsal third. This region is essential for THR stability, but the degree of contact between the septum and standard THR implants has never been studied. We obtained CT scans of 50 arthrotic hip joints from patients requiring THR. Virtual stems (50 straight/wedge-shaped and 50 anatomic stems) were placed in CT images of the femora using a PC-based preoperative planning unit. The dimensions of the septum, degree and location of contact between the septum a…