Search results for "Image"
showing 10 items of 6818 documents
Comparison of Histochemical Stainings in Evaluation of Liver Fibrosis and Correlation with Transient Elastography in Chronic Hepatitis.
2015
Background and Aim. The best staining to evaluate liver fibrosis in liver hepatitis is still a debated topic. This study aimed to compare Masson’s trichrome (MT), Sirius Red (SR), and orcein stainings in evaluating liver fibrosis in chronic HCV hepatitis (CHC) with semiquantitative and quantitative methods (Collagen Proportionate Area (CPA) by Digital Image Analysis (DIA)) and correlate them with transient elastography (TE).Methods. Liver stiffness evaluation of 111 consecutive patients with CHC was performed by TE. Semiquantitative staging by Metavir score system and CPA by DIA were assessed on liver biopsy stained with MT, SR, and orcein.Results. MT, SR, and orcein staining showed concord…
Digital image analysis of collagen assessment of progression of fibrosis in recurrent HCV after liver transplantation
2013
BACKGROUND & AIMS: Histological assessment of fibrosis progression is currently performed by staging systems which are not continuous quantitative measurements. We aimed at assessing a quantitative measurement of fibrosis collagen proportionate area (CPA), to evaluate fibrosis progression and compare it to Ishak stage progression. METHODS: We studied a consecutive cohort of 155 patients with recurrent HCV hepatitis after liver transplantation (LT), who had liver biopsies at one year and were subsequently evaluated for progression of fibrosis using CPA and Ishak staging, and correlated with clinical decompensation. The upper quartile of distribution of fibrosis rates (difference in CPA or Is…
The relationship between transient elastography and histological collagen proportionate area for assessing fibrosis in chronic viral hepatitis
2012
Collagen proportionate area (CPA) has a better correlation with hepatic venous pressure gradient (HVPG) than with Ishak stage. Liver stiffness measurement (LSM) is proposed as non invasive marker of portal hypertension/disease progression. Our aim was to compare LSM and CPA with Ishak staging in chronic viral hepatitis, and HVPG in HCV hepatitis after transplantation. One hundred and sixty-nine consecutive patients with chronic hepatitis B virus (HBV) or hepatitis C virus (HCV) infections pre/post liver transplantation (LT), had a liver biopsy combined with LSM (transient elastography), CPA (biopsies stained with Sirius Red and evaluated by digital image analysis and expressed as CPA) and H…
Computer-assisted image analysis of liver collagen: relationship to Ishak scoring and hepatic venous pressure gradient.
2009
Histopathological scoring of disease stage uses descriptive categories without measuring the amount of fibrosis. Collagen, the major component of fibrous tissue, can be quantified by computer-assisted digital image analysis (DIA) using histological sections. We determined relationships between DIA, Ishak stage, and hepatic venous pressure gradient (HVPG) reflecting severity of fibrosis. One hundred fifteen patients with hepatitis C virus (HCV) who had undergone transplantation had 250 consecutive transjugular liver biopsies combined with HVPG (median length, 22 mm; median total portal tracts, 12), evaluated using the Ishak system and stained with Sirus red for DIA. Liver collagen was expres…
Focal confluent fibrosis in cirrhotic liver: natural history studied with serial CT.
2009
The objective of this study was to assess the long-term natural history of focal confluent fibrosis in cirrhotic liver with CT.Two radiologists retrospectively reviewed in consensus 118 liver CT examinations in 26 patients (19 men, seven women; age range, 32-68 years; mean age, 50 years) performed over approximately 6 years. Helical CT scans were obtained before and 30-35 and 65-70 seconds after injection of 125-150 mL of contrast medium at a rate of 4-5 mL/s. Proof of cirrhosis was based on liver transplantation (n = 6), biopsy (n = 9), or imaging findings (n = 11). The number, location, and attenuation of fibrotic lesions and presence of trapped vessels were evaluated. Variation of hepati…
Diagnostic value of MR-based texture analysis for the assessment of hepatic fibrosis in patients with nonalcoholic fatty liver disease (NAFLD)
2019
PurposeTo investigate the performance of MR-based texture analysis (TA) for the assessment of hepatic fibrosis in patients with nonalcoholic fatty liver disease (NAFLD).MethodsFifty-four adult patients (33 females, 21 males, mean age 49.813.5years) with biopsy-proven NAFLD were enrolled and underwent MR imaging on a 1.5T system. TA parameters were extracted on axial noncontrast 3D-GRE T1W images (slice thickness=4.6mm) using a commercially available research software (TexRAD). Receiver operating curves (ROC), areas under the ROC (AUROC) and 95% confidence intervals (CI) were calculated to assess the accuracy of each TA parameter for the diagnosis of significant (F2) and advanced fibrosis (F…
Analysis of different contrast enhancement patterns after microbubble-based contrast agent injection in liver hemangiomas with atypical appearance on…
2006
BACKGROUND: We describe different possible enhancement patterns in liver hemangiomas with atypical appearance on baseline ultrasound after microbubble-based contrast agent injection. METHODS: From a series of 253 consecutive lesions that were indeterminate on baseline ultrasound and then scanned after injection of air-filled microbubble contrast agent, 65 focal liver lesions were retrospectively selected on the basis of a diagnosis of liver hemangioma on multiphase contrast-enhanced computed tomography (n = 23), magnetic resonance imaging (n = 27), or histology (n = 15). Each lesion was scanned during arterial phase (30 s after microbubble injection) and late phase (5 min after injection). …
Imaging of the lungs using 3he MRI: Preliminary clinical experience in 18 patients with and without lung disease
1997
The purpose of this study was to describe the 3He MRI findings of normal pulmonary ventilation in healthy volunteers and to evaluate abnormalities in patients with different lung diseases. Hyperpolarized 3He gas (300 ml, 3 x 10(5) Pa, polarized to 35-45% by optical pumping, provided in special glass cells) was inhaled by 8 healthy volunteers and 10 patients with different lung diseases. Imaging was performed with a three-dimensional fast low-angle shot (FLASH) sequence (TR = 11.8 msec; TE = 5 msec; transmitter amplitude, 5-8 V; corresponding flip angle, < 5 degrees) in a single breath-hold (22-42 seconds). Clinical and radiological examinations were available for correlation. The studies we…
Potential clinical value of quantitative fluorine-18-fluorodeoxyglucose-PET/computed tomography using a graph-based method analysis in evaluation of …
2019
Objectives To identify the clinical relevance of incidentally detected lesions (IDLs) in the gastrointestinal tract (GIT) with 18F-FDG PET/CT and to assess the potential benefit of using semiquantitative PET measures to discern malignant from benign lesions. Methods Forty-one patients who underwent F-FDG PET/CT scans during the oncologic follow-up, revealing abnormal incidental 18F-FDG accumulations in the GIT were included in this retrospective analysis. Incidental PET/CT findings were correlated with endoscopic and histological findings. Semiquantitative PET values (SUVmax, SUVmean, SULpeak, and TLG) were evaluated by using a new graph-based method. Two sample t-test analysis has been per…
Validation of ThermoHuman automatic thermographic software for assessing foot temperature before and after running
2020
The aim of the study was to evaluate an automatic thermographic software package (ThermoHuman®) for assessing skin temperature on the soles of the feet before and after running and to compare it with two manual definitions of the regions of interest (ROIs). 120 thermal images of the soles of the feet of 30 participants, at two measurement points (before and after running 30 min) and on two measurement days were analyzed. Three different models of thermographic image analyses were used to obtain the mean temperature of 9 ROIs: A) ThermoHuman (automatic definition of ROIs using ThermoHuman® software), B) Manual (manual delimitation of ROIs by proportion criteria), and C) Manual-TH (manual del…