Search results for "Image"

showing 10 items of 6818 documents

Pelvic Exenteration: Effects of Surgery on Quality of Life and Body Image—A Prospective Longitudinal Study

1997

Abstract Objectives. The goal of this study was to evaluate the impact of reconstructive and nonreconstructive surgical procedures on quality of life and body image for women who undergo pelvic exenteration. Methods. Twenty-eight patients were assessed in a prospective study with a preoperative semistructured interview and an objective assessment (T1). Interviews and questionnaires were repeated 4 (T2) and 12 (T3) months postoperatively. The women were divided into groups with two, one, or no ostomies. A separate comparison was made of women with and without vaginal capacity. Quality of life was defined in terms of five categories according to the definition of health proposed by the World …

Adultmedicine.medical_specialtyLongitudinal studymedicine.medical_treatmentWorld healthObjective assessmentQuality of lifeSurveys and QuestionnairesBody ImagemedicineHumansIn patientProspective StudiesProspective cohort studyAgedPelvic exenterationbusiness.industryObstetrics and GynecologyMiddle AgedPelvic ExenterationSurgeryOncologyQuality of LifeFemalebusinessPsychosocialGynecologic Oncology
researchProduct

Endo-neuro-sonography: principles and 3-D technique

1997

To evaluate the usefulness of transendoscopic sonography we studied two new sono probes 6 F in diameter in 17 fresh specimens. We saw precise imaging of well-known anatomical structures and also gained an additional dimension in endoscopy, as the sono adds to the endo-view a transverse scan like a mini-CT at the tip of the probe. We also experienced the navigation characteristic of this imaging technique, both in real time and on line. Some 3-D reconstructions of the ventricular system were examined. The equipment has been used in clinical practice and must now be adapted for neurosurgery.

Adultmedicine.medical_specialtyNeuronavigationmedicine.diagnostic_testbusiness.industryAnatomical structuresBrainEndoscopic anatomyGeneral MedicineEchoencephalographyEndosonographySurgeryEndoscopyClinical PracticeChild PreschoolPediatrics Perinatology and Child HealthImage Processing Computer-AssistedHumansMedicineNeurology (clinical)Imaging techniqueTomography X-Ray ComputedbusinessBiomedical engineeringChild's Nervous System
researchProduct

Virtual reality treatment of claustrophobia: a case report.

1998

The efficacy of a treatment for claustrophobia using only Virtual Reality (VR) exposure was examined. The subject was a 43-year-old female who suffered from clinically significant distress and impairment and sought psychological therapy. Eight individual VR graded exposure sessions were conducted. All self-report measures were reduced following VR exposure and were maintained at one month follow-up. The necessity of a theoretical framework for this new medium for exposure therapy is discussed.

Adultmedicine.medical_specialtyPsychotherapistmedicine.medical_treatmentExposure therapyPsychological therapyExperimental and Cognitive PsychologyVirtual realityUser-Computer InterfacemedicineImage Processing Computer-AssistedHumansFollow up studiesmedicine.diseaseDesensitization (psychology)Psychiatry and Mental healthClinical PsychologyDistressPhobic DisordersPhysical therapyClaustrophobiaFemaleDesensitization PsychologicPsychologyArousalAnxiety disorderFollow-Up StudiesBehaviour research and therapy
researchProduct

The impact of treatment for genital cancer on quality of life and body image—results of a prospective longitudinal 10-year study

2003

Abstract Objective . To evaluate the impact of treatment for genital cancer on quality of life and body image to determine patients' therapy-related needs for quality improvement of medical care before and after surgery. Methods . We started to evaluate women with cervical cancer planned for pelvic exenteration in 1993 and integrated women planned for a Wertheim–Meigs surgery in 1995 before surgery, 4 and 12 months after surgery. Thanks to funding since 1999, more than 400 patients with a diagnosis of genital ( n = 185) or breast ( n = 217) cancer participated in this prospective study until July 2003. In this paper, we will focus on n = 129 women with cervical cancer. The assessment protoc…

Adultmedicine.medical_specialtyReconstructive surgeryQuality managementmedicine.medical_treatmentUterine Cervical NeoplasmsHysterectomyQuality of lifeBody ImageHumansMedicineLongitudinal StudiesProspective StudiesProspective cohort studyAgedCervical cancerHysterectomyPelvic exenterationbusiness.industryObstetrics and GynecologyMiddle Agedmedicine.diseasePelvic ExenterationOncologyQuality of LifePhysical therapyFemalebusinessSexualityPsychosocialGynecologic Oncology
researchProduct

Lymphoscintigraphy with peritumoral injection versus lymphoscintigraphy with subdermal periareolar injection of technetium-labeled human albumin to i…

2014

Background Preoperative lymphoscintigraphy is without doubt a valid method for the detection of the sentinel lymph node (SLN). There has been considerable debate regarding the optimal site for the introduction of the tracer; various sites include peritumoral (PT), periareolar (PA), subdermal, and intradermal injection. Purpose To evaluate retrospectively the lymphoscintigraphic identification rate of peritumoral (PT) injection versus subdermal periareolar (PA) injection in the detection of SLNs in breast cancer. Material and Methods Between October 2002 and December 2011, a cohort of 906 consecutive patients with biopsy proven breast cancer underwent 914 SLN biopsy procedures. A total of 33…

Adultmedicine.medical_specialtySentinel lymph nodechemistry.chemical_elementBreast NeoplasmsInjections IntralesionalTechnetiumPeriareolarBreast cancerBiopsymedicineCarcinomaHumansRadiology Nuclear Medicine and imagingTechnetium Tc 99m Aggregated AlbuminAgedRetrospective StudiesAged 80 and overBreast cancer sentinel lymph node biopsy lymphoscintigraphy sub areolar peritumoral radio-colloidRadiological and Ultrasound Technologymedicine.diagnostic_testSentinel Lymph Node Biopsybusiness.industryHuman albuminGeneral MedicineMiddle AgedImage Enhancementmedicine.diseaseSurgerychemistryFemaleLymphRadiopharmaceuticalsSettore MED/36 - Diagnostica Per Immagini E RadioterapiaNuclear medicinebusinessLymphoscintigraphyActa Radiologica
researchProduct

Assessment of the implantation of day-2 human embryos by morphometric nonsubjective parameters

2014

Objective: To demonstrate the usefulness of image analysis in designing objective embryonic morphometric variables. Design: Retrospective study of 214 top-quality day-2 embryo photographs from 50 double-embryo transfers resulting in no pregnancy (group 0) and 57 resulting in twin pregnancy (group 1). Setting: Human reproduction unit. Patient(s): Study of 107 in vitro fertilization intracytoplasmic sperm injection (IVF ICSI) cycles in women age<36 years with doubleembryo transfer of top-quality embryos. Only the first cycle of IVF ICSI was included. Intervention(s): Standard IVF ICSI protocols. Main Outcome Measure(s): The embryo photographs were analyzed using the ImageJ program. The effect…

Adultmedicine.medical_specialtyTime Factorsanimal structuresESTADISTICA E INVESTIGACION OPERATIVAFertilization in VitroBiologyPRODUCCION ANIMALEmbryo grading systemsPredictive Value of TestsPregnancymedicineOdds RatioHumansSperm Injections Intracytoplasmicreproductive and urinary physiologyRetrospective StudiesGynecologyEmbryo scoreurogenital systemMorphological and morphometric embryo variablesAge FactorsObstetrics and GynecologyEmbryoAnatomyEmbryo TransferEmbryo MammalianLogistic ModelsReproductive Medicineembryonic structuresEmbryo implantationPregnancy TwinFemaleEmbryo selectionImages analysis
researchProduct

A New Systematic Classification of Peripheral Anatomy of the Right Hepatic Duct: Experience From Adult Live Liver Donor Transplantation

2008

Abstract Objective The peripheral intrahepatic biliary anatomy, especially at the sectorial level on the right side, has not been adequately described. The purpose of our study was to systematically describe this complex anatomy in clinically applicable fashion. Patients and Methods We analyzed three-dimensional computed tomography (CT) imaging reconstructions of 139 potential living liver donors evaluated at our institution between January 2003 and June 2007. Results Eighty-nine (64%) donors had a normal right bile duct sectorial anatomy. In the other 50/139 (36%) cases, we observed abnormal sectorial branching patterns, with 45/50 abnormalities as trifurcations, whereas the remaining ones…

Adultmedicine.medical_treatmentHepatic Duct CommonLiver transplantationAnastomosisFunctional LateralityCholangiographyImage Processing Computer-AssistedLiving DonorsmedicineHumansSurvivorsTransplantationmedicine.diagnostic_testBile ductbusiness.industryGallbladderAnastomosis SurgicalGallbladderAnatomyLobeCholecystographyLiver TransplantationSurvival RateTransplantationmedicine.anatomical_structureSurgeryBile DuctsHepatectomyTomography X-Ray ComputedbusinessCholangiographyTransplantation Proceedings
researchProduct

The use of computer-assisted video image analysis for the quantification of CD8+ T lymphocytes producing tumor necrosis factor alpha spots in respons…

1997

Enzyme-linked immunospot (ELISPOT) analysis is a sensitive technique for the detection and quantification of single T lymphocytes forming cytokine spots after antigen contact in vitro. Herein computer-assisted video image analysis (CVIA) was applied to automatically determine the number and size of tumor necrosis factor alpha (TNF-alpha) spots formed by single blood-derived CD8+ T cells after contact with peptide-loaded target cells. With CVIA and TNF-alpha ELISPOT analysis we quantified CD8+ T cells responsive to HLA-A2.1-binding tyrosinase and influenza matrix peptides in healthy donors. We followed the course of the virus-specific T cell response in two HLA-A2-positive patients with reac…

Adultmedicine.medical_treatmentT cellImmunologyCytomegalovirusEnzyme-Linked Immunosorbent AssayBiologyCD8-Positive T-LymphocytesCell LineAntigenViral Envelope ProteinsHLA-A2 AntigenmedicineImage Processing Computer-AssistedImmunology and AllergyHumansLymphocyte CountMicroscopy VideoTumor Necrosis Factor-alphaELISPOTMiddle AgedMolecular biologyIn vitroCytokinemedicine.anatomical_structureCell cultureImmunologyCytomegalovirus InfectionsTumor necrosis factor alphaPeptidesCD8Journal of immunological methods
researchProduct

Multicenter validation of the magnetic resonance t2* technique for segmental and global quantification of myocardial iron

2009

Purpose To assess the transferability of the magnetic resonance imaging (MRI) multislice multiecho T2* technique for global and segmental measurement of iron overload in thalassemia patients. Materials and Methods Multiecho T2* sequences were installed on six MRI scanners. Five healthy subjects (n = 30) were scanned at each site; five thalassemia major (TM) patients were scanned at the reference site and were rescanned locally (n = 25) within 1 month. T2* images were analyzed using previously validated software. Results T2* values of healthy subjects showed intersite homogeneity. On TM patients, for global heart T2* values the correlation coefficient was 0.97, coefficients of variation (CoV…

Adultmyocardial iron; T2* techniqueCorrelation coefficientHeart VentriclesIronReference siteTransferabilityMyocardial ironReference ValuesImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingMultislicemyocardial ironAnalysis of VarianceReproducibilitymedicine.diagnostic_testbusiness.industryMyocardiumHealthy subjectsT2* techniqueReproducibility of ResultsMagnetic resonance imagingMagnetic Resonance ImagingItalyLiverThalassemiabusinessNuclear medicineJournal of Magnetic Resonance Imaging
researchProduct

Multisensor comparison of NDVI for a semi‐arid environment in Spain

2009

The joint use of multiresolution sensors from different satellites offers many opportunities to describe vegetation and its dynamics. This paper introduces the concept of a virtual constellation (defined as an ensemble of all Earth Observation satellites in orbit that satisfy common requirements) for agricultural applications and contributes to providing the necessary inter-sensor calibration methodology for spectral reflectances and NDVI. For this purpose, we performed an observational study, comparing reflectances and the Normalized Difference Vegetation Index (NDVI), from near-synchronous image pairs of Landsat 7 Enhanced Thematic Mapper Plus (ETM+), as the reference sensor and Landsat 5…

Advanced Spaceborne Thermal Emission and Reflection RadiometerRadiometerAdvanced very-high-resolution radiometerThematic MapperGeneral Earth and Planetary SciencesEnvironmental scienceSatellite imageryVegetationPrecision agricultureNormalized Difference Vegetation IndexRemote sensingInternational Journal of Remote Sensing
researchProduct