Search results for "Imaging phantom"

showing 10 items of 127 documents

Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

2013

Purpose : The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using60Co or 192 Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods : Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference…

business.industryEquivalent dosemedicine.medical_treatmentBrachytherapyGeneral MedicineEffective dose (radiation)Imaging phantomRadiation therapyAbsorbed doseMedicineDosimetrybusinessNuclear medicineProton therapyMedical Physics
researchProduct

Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source.

2011

Purpose: Recently, a new HDR 60 Co brachytherapy source, Flexisource Co-60, has been developed (Nucletron B.V. Veenendaal, The Netherlands). This study aims to obtain dosimetric data for this source for its use in clinical practice as required by AAPM and ESTRO. Material and methods: Two Monte Carlo radiation transport codes were used: Penelope2008 and GEANT4. The source was centrally-positioned in a 100 cm radius water phantom. Absorbed dose and collisional kerma were obtained using 0.01 cm (close) and 0.1 cm (far) sized voxels to provide high-resolution dosimetry near (far from) the source. Dose rate distributions obtained with the two Monte Carlo codes were compared. Results and Discussi…

business.industryFlexisource Co-60Penelope2008medicine.medical_treatmentBrachytherapyMonte Carlo methodbrachytherapyImaging phantomComputational physicsKermaOncologyAbsorbed doseMedicineDosimetryRadiology Nuclear Medicine and imagingOriginal ArticlebusinessDose rateRadiation treatment planningNuclear medicineTG-43GEANT4Journal of contemporary brachytherapy
researchProduct

TH-C-AUD A-07: Evaluation of the Correction Factor Due to the Lack of Full Scatter Conditions in Cs-137 and Ir-192 Brachytherapy Dosimetric Studies

2008

Purpose: Use of a finite phantom to derive dose rate distributions around brachytherapysources implies a lack of backscattering material near the phantom periphery. Conventional planning algorithms and newly‐developed 3D correction algorithms are based on physics data under full scatter conditions. Presently, most published Monte Carlodosimetric studies have been obtained using either a spherical phantom (15cm in radius) or a cylinder phantom (40×40cm2). The study objective was to derive a simple relationship to correlate the radial dose function, g(r), obtained for each one of these phantoms to that obtained for an unbounded phantom. Method and Materials: Assuming bare point sources of 137…

business.industryMonte Carlo methodGeneral MedicineRadiusImaging phantomComputational physicsKermaOpticsConsistency (statistics)Bounded functionDosimetryCylinderbusinessMathematicsMedical Physics
researchProduct

WE-C-108-08: Organ Doses in a Male Phantom Undergoing High-Dose-Rate Brachytherapy Applied to the Prostate

2013

Purpose: The aim of this study was to obtain equivalent doses to radiosensitive organs when applying high‐dose‐rate (HDR) brachytherapy to the prostate using60 Co or 192 Ir sources, and in comparison to external‐beam radiotherapy (EBRT) modalities. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized adult reference man described in Publication 110 by the International Commission on Radiological Protection (ICRP). Point sources of 60Co or 192Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate. Equivalent doses per therapeutic absorbed dose to the prostate were obtained in several radiosensitive organs. …

business.industrymedicine.medical_treatmentBrachytherapyGeneral MedicineImaging phantomHigh-Dose Rate BrachytherapyRadiation therapymedicine.anatomical_structureProstateAbsorbed dosemedicineDosimetrybusinessNuclear medicineProton therapyMedical Physics
researchProduct

Monte Carlo dosimetric study of Best Industries and Alpha Omega Ir-192 brachytherapy seeds

2004

Ir-192 seeds are widely used in the USA for low dose rate interstitial brachytherapy. There are two commercially available models: those manufactured by Best Industries filtered with stainless steel, and those manufactured by Alpha-Omega seeds filtered with Pt. Newly developed 3D correction algorithms for brachytherapy are based on dosimetry data obtained on unbounded phantom size, allowing corrections for heterogeneities and actual tissue boundaries. Published dosimetric datasets for both seeds have been obtained under bounded conditions. The aim of the present study is to obtain dosimetric datasets for these seeds under full scatter conditions. The Monte Carlo GEANT4 code has been used to…

business.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineOmegaImaging phantomComputational physicsKermamedicineDosimetryAnisotropyNuclear medicinebusinessImage resolutionMathematicsMedical Physics
researchProduct

Combined Endo- and Exoscopic Semi-robotic Manipulator System for Image Guided Operations

2006

This paper describes the development of a robotic assistance system for image guided operations. To minimize operation time, a multimodal user interface enables freehand robotic manipulation of an extracorporeal stereoscopic digital camera (exoscope) and an endoscope. The surgeon thereby wears a head-mounted unit with a binocular display, a head tracker, a microphone and earphones. Different view positioning and adjustment modes can be selected by voice and controlled by head rotation while pressing a miniature confirmation button with a finger. Initial studies focused on the evaluation and optimization of the intuitiveness, comfort and precision of different modes of operation, including a…

business.product_categoryComputer scienceMicrophonebusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONRobot manipulatorStereoscopyVirtual realityImaging phantomlaw.inventionImage (mathematics)lawSystem integrationComputer visionArtificial intelligenceUser interfacebusinessSimulationDigital camera
researchProduct

IC‐P‐050: The European diffusion tensor imaging study in dementia (EDSD): Physical phantom study and multimodal clinical study on the diagnosis of Al…

2012

medicine.medical_specialtyEpidemiologybusiness.industryHealth PolicyDiseasemedicine.diseaseImaging phantomClinical studyPsychiatry and Mental healthCellular and Molecular NeuroscienceDevelopmental NeurosciencemedicineDementiaMedical physicsNeurology (clinical)Geriatrics and GerontologybusinessNeuroscienceDiffusion MRIAlzheimer's & Dementia
researchProduct

Implementation of dosimetry equipment and phantoms at the MedAustron light ion beam therapy facility

2017

Purpose: To describe the implementation of dosimetry equipment and phantoms into clinical practice of light ion beam therapy facilities. This work covers standard dosimetry equipment such as computerized water scanners, films, 2D-array, thimble and plane parallel ionization chambers, but also dosimetry equipment specifically devoted to the pencil beam scanning delivery technique such as water columns, scintillating screens or multi-layer ionization chambers. Method: Advanced acceptance testing procedures developed at MedAustron and complementary to the standard acceptance procedures proposed by the manufacturer are presented. Detailed commissioning plans have been implemented for each piece…

medicine.medical_specialtyIon beamComputer scienceNuclear engineeringmedicine.medical_treatmentImaging phantomPelvis030218 nuclear medicine & medical imagingMedical physicist03 medical and health sciences0302 clinical medicinemedicineHumansDosimetryMedical physicsRadiometryPencil-beam scanningIonsPhantoms ImagingRadiation DosimetersUncertaintyGeneral MedicinePencil (optics)Radiation therapy030220 oncology & carcinogenesisSoftwareMedical Physics
researchProduct

Verification of a commercial implementation of the Macro-Monte-Carlo electron dose calculation algorithm using the virtual accelerator approach.

2009

Abstract In this work, the accuracy of the implementation of the Macro Monte Carlo electron dose calculation algorithm into the radiation therapy treatment planning system Eclipse is evaluated. This implementation – called eMC – uses a particle source based on the Rotterdam Initial Phase-Space model. A three-dimensional comparison of eMC calculated dose to dose distributions resulting from full treatment head simulations with the Monte Carlo code package EGSnrc is performed using the ‘virtual accelerator’ approach. Calculated dose distributions are compared for a homogeneous tissue equivalent phantom and a water phantom with air and bone inhomogeneities. The performance of the eMC algorithm…

medicine.medical_specialtyMonte Carlo methodBiophysicsElectronsImaging phantomUser-Computer InterfaceElectron dosemedicineHumansRadiology Nuclear Medicine and imagingMedical physicsMacroLungEclipsePhysicsRadiological and Ultrasound TechnologyPhantoms ImagingRadiotherapy Planning Computer-AssistedCalculation algorithmWaterRadiotherapy DosageSpineComputational physicsRadiographyTracheaTissue equivalentHomogeneousHeadMonte Carlo MethodAlgorithmsZeitschrift fur medizinische Physik
researchProduct

2017

Objective Computer-aided-surgery in ENT surgery is mainly used for sinus surgery but navigation accuracy still reaches its limits for skull base procedures. Knowledge of navigation accuracy in distinct anatomical regions is therefore mandatory. This study examined whether navigation accuracy can be improved in specific anatomical localizations by using hybrid registration technique. Study design Experimental phantom study. Setting Operating room. Subjects and methods The gold standard of screw registration was compared with automatic LED-mask-registration alone, and in combination with additional surface matching. 3D-printer-based skull models with individual fabricated silicone skin were u…

medicine.medical_specialtyMultidisciplinarybusiness.industryComputer scienceGold standard (test)Sinus surgeryImaging phantomSurgery03 medical and health sciencesSkull0302 clinical medicinemedicine.anatomical_structureSkull base surgerymedicineComputer visionArtificial intelligence030223 otorhinolaryngologyFiducial markerbusiness030217 neurology & neurosurgerySinus (anatomy)PLOS ONE
researchProduct