SU-FF-T-15: Comparison of Various Monte Carlo Codes for Brachytherapy Source Dosimetry
2009
Purpose: Monte Carlo simulations are used for dosimetric evaluation of brachytherapysources. Various investigators had demonstrated good agreement between the measured and simulated data while some others have shown discrepancies between the two methods. These discrepancies were attributed to the errors in cross section data, differences in phantom and source geometry and composition. However, the exact causes of these differences have not yet fully explored. The goal of this project is to verify the differences among the widely available Monte Carlo codes for brachytherapysourcedosimetry.Material and method: These investigations are based on VariSource 192 Ir , Model VS2000, IsoAid Advanta…
246. Analysis of signal-to-noise ratio for a 2-channels coil developed to enable transcranial Magnetic Resonance-guided Focused Ultrasound Surgery (t…
2018
Abstract Purpose In recent years trans-cranial Magnetic Resonance-guided Focused Ultrasound Surgery (tcMRgFUS) treatments have aroused large scientific and medical interest [1] . Usually, tcMRgFUS systems are integrated with 3 T systems which allow the use of the body RF coil for both real time imaging and MR-thermometry. At University Hospital of Palermo there is the world-first installation of a tcMRgFUS system integrated with a 1.5 T scanner. Here we present the characterization in terms of signal-to-noise ratio (SNR) of a dedicated RF coils suitably developed (by InSightec) to enable tcMRgFUS treatments with 1.5 T MR units. Methods and materials The focused ultrasound equipment (ExAblat…
Next generation of the Albira small animal PET based on high density SiPM arrays
2015
A new design of the small animal PET Albira system which detectors are based on arrays of SiPMs and monolithic LYSO scintillator is presented here. The system is made out of 3 rings of 8 detectors each, resulting on an axial and transaxial FOVs of 148 and 80 mm, respectively. The scanner is thermally stabilized using air-cooling. Working temperatures around 22–25°C are reached with individual detector variations around 0.2°C minimizing dark count rates and gain drifts. One of the most significant improvements of the current system is the accurate photon impact determination within the crystal volume, specially its depth of interaction. This allows the calculation of the true line of respons…
The AX-PET Concept: New Developments And Tomographic Imaging
2011
The Axial PET (AX-PET) concept proposes a novel detection geometry for PET, based on layers of long scintillating crystals axially aligned with the bore axis. Arrays of wavelength shifting (WLS) strips are placed orthogonally and underneath the crystal layers; both crystals and strips are individually readout by G-APDs. The axial coordinate is obtained from the WLS signals by means of a Center-of-Gravity method combined with a cluster algorithm. This design allows spatial resolution and sensitivity to be decoupled and thus simultaneously optimized. In this work we present the latest results obtained with the 2-module AX-PET scanner prototype, which consists of 6 radial layers of 8 LYSO crys…
Optimal geometry for efficient loading of an optical dipole trap
2009
One important factor which determines efficiency of loading cold atoms into an optical dipole trap from a magneto-optical trap is the distance between the trap centers. By studying this efficiency for various optical trap depths (2--110 mK) we find that for optimum dipole trap loading, longitudinal displacements up to 15 mm are necessary. An explanation for this observation is presented and compared with other work and a simple analytical formula is derived for the optimum distance between the trap centers.
Robust Two-Dimensional Electronic Properties in Three-Dimensional Microstructures of Rotationally Stacked Turbostratic Graphene
2017
We report on the electronic properties of turbostratic graphitic microdisks, rotationally stacked systems of graphene layers, where interlayer twisting leads to electronic decoupling resulting in charge-transport properties that retain the two dimensionality of graphene, despite the presence of a large number of layers. A key fingerprint of this reduced dimensionality is the effect of weak charge-carrier localization that we observe at low temperatures. The disks' resistivity measured as a function of magnetic field changes its shape from parabolic at room temperature to linear at a temperature of 2.7 K indicating further this type of two-dimensional transport. Compared to Bernal stacked gr…
SU-F-T-13: Transit Dose Comparisons for Co-60 and Ir-192 HDR Sources
2016
Purpose: The purpose of this study is to compare the transit dose due to the movement of high dose rate (HDR) Ir-192 and Co-60 sources along the transfer tube. This is performed by evaluating air-kerma differences in the vicinity of the transfer tube when both sources are moved with the same velocity from a HDR brachytherapy afterloader into a patient. Methods: Monte Carlo simulations have been performed using PENELOPE2014. mHDR-v2 and Flexisource sources have been considered. Collisional kerma has been scored. The sources were simulated within a plastic catheter located in an infinite air phantom. The movement of the seed was included by displacing their positions along the connecting cath…
Comparaison de la mesure des déformations de fantômes de l’aorte à partir d’image obtenues par IRM et stéréovision
2015
International audience; The study of the wall strain distribution could be helpful to improve the decision criterion for surgery of aortic aneurysm. Recently, numerical simulations can complete the data obtained from imaging measurement in order to develop reliable models. However, the used medical imaging tools are not experimentally validated, in metrological point of view. The aim of this study focused on accuracy and reliability of measurement obtained from kinetic MR sequences. The measures of deformations from MRI were compare to those obtained from stereovision system. Cylindrical phantom of silicone material similar to arterial behavior simulated a symmetric aneurysm was designed. A…
Optical gratings induced by field-free alignment of molecules
2006
We analyze the alignment of molecules generated by a pair of crossed ultra-short pump pulses of different polarizations by a technique based on the induced time-dependent gratings. Parallel polarizations yield an intensity grating, while perpendicular polarizations induce a polarization grating. We show that both configurations can be interpreted at moderate intensity as an alignment induced by a single polarized pump pulse. The advantage of the perpendicular polarizations is to give a signal of alignment that is free from the plasma contribution. Experiments on femtosecond transient gratings with aligned molecules were performed in CO2 at room temperature in a static cell and at 30 K in a …
SU-GG-T-70: A Dosimetric Study of the MicroSelectron HDR Ir-192 Brachytherapy Source
2010
Purpose: Recently the manufacturer of the mHDR‐v2 HDR Ir‐192 brachytherapy source clarified design changes that may alter the existing dosimetric data for this source. The object of this study was to obtain new dose rate tables following the TG‐43 formalism and to provide these data in close proximity to the source with high spatial resolution including the electron dosimetric contributions from Ir‐192 disintegration. Methods and Material: To study the source we used three different Monte Carlo codes: MCNP5, GEANT4, and Penelope. The source was located inside a 40 cm radius water phantom. Dose and kerma were obtained using 0.1 mm thick voxels to provide high‐resolution dosimetry near the so…