Search results for "Immediate"

showing 10 items of 175 documents

The Immune Evasion Paradox: Immunoevasins of Murine Cytomegalovirus Enhance Priming of CD8 T Cells by Preventing Negative Feedback Regulation▿

2008

ABSTRACTCytomegaloviruses express glycoproteins that interfere with antigen presentation to CD8 T cells. Although the molecular modes of action of these “immunoevasins” differ between cytomegalovirus species, the convergent biological outcome is an inhibition of the recognition of infected cells. In murine cytomegalovirus, m152/gp40 retains peptide-loaded major histocompatibility complex class I molecules in acis-Golgi compartment, m06/gp48 mediates their vesicular sorting for lysosomal degradation, and m04/gp34, although not an immunoevasin in its own right, appears to assist in the concerted action of all three molecules. Using the Ld-restricted IE1 epitope YPHFMPTNL in the BALB/c mouse m…

MuromegalovirusImmunologyAntigen presentationPriming (immunology)Genome ViralBiologyCD8-Positive T-LymphocytesMajor histocompatibility complexVirus ReplicationMicrobiologyEpitopeImmediate early proteinImmediate-Early ProteinsEpitopesMiceViral ProteinsImmune systemAntigenVirologyCytotoxic T cellAnimalsAntigen PresentationMice Inbred BALB CHerpesviridae InfectionsKiller Cells NaturalInsect ScienceImmunologybiology.proteinPathogenesis and ImmunityFemaleLymph NodesImmunologic MemorySpleen
researchProduct

Identification of a Kd-restricted antigenic peptide encoded by murine cytomegalovirus early gene M84

2000

The two sister cytomegaloviruses (CMVs), human and murine CMV, have both evolved immune evasion functions that interfere with the major histocompatibility complex class I (MHC-I) pathway of antigen processing and presentation and are effectual in the early (E) phase of virus gene expression. However, studies on murine CMV have shown that E-phase immune evasion is leaky. An E-phase protein involved in immune evasion, namely m04-gp34, was found to simultaneously account for an antigenic peptide presented by the MHC-I molecule Dd. Recent work has demonstrated the induction of protective immunity specific for the E-phase protein M84-p65, one of two murine CMV homologues of the human CMV matrix …

MuromegalovirusPeptideBiologyMajor histocompatibility complexImmediate-Early ProteinsMiceOpen Reading FramesImmune systemVirologyAnimalsAmino Acid SequenceLymphocyte CountAntigens ViralGenes Immediate-EarlyGeneAntigenic peptidechemistry.chemical_classificationMice Inbred BALB CViral matrix proteinAntigen processingH-2 AntigensVirologyMolecular biologyPeptide FragmentschemistryCytomegalovirus earlybiology.proteinImmunologic MemoryT-Lymphocytes CytotoxicJournal of General Virology
researchProduct

Early gene m18, a novel player in the immune response to murine cytomegalovirus

2002

The identification of all antigenic peptides encoded by a pathogen, its T cell ‘immunome’, is a research aim for rational vaccine design. Screening of proteome-spanning peptide libraries or computational prediction is used to identify antigenic peptides recognized by CD8 T cells. Based on their high coding capacity, cytomegaloviruses (CMVs) could specify numerous antigenic peptides. Yet, current evidence indicates that the memory CD8 T cell response in a given haplotype is actually focused on a few viral proteins. CMVs actively interfere with antigen processing and presentation by the expression of immune evasion proteins. In the case of murine CMV (mCMV), these proteins are effectual in th…

MuromegalovirusT cellMolecular Sequence DataCD8-Positive T-LymphocytesBiologyVirus ReplicationVirusImmediate-Early ProteinsMiceImmune systemVirologymedicineAntigenic variationAnimalsCytotoxic T cellAntigens ViralGeneCells CulturedBase SequenceAntigen processingFibroblastsVirologymedicine.anatomical_structureViral replicationPeptidesImmunologic MemoryJournal of General Virology
researchProduct

Immediate Loading in Atrophic Jaws: Zygomatic Implants

2019

The zygomatic fixture is an extended length (35–55 mm) titanium implant, placed into the zygomatic and maxillary alveolar bone. It was designed for situations where atrophy of the posterior maxilla complicates or prevents the placing of conventional implants. The use of zygomatic implants avoids the need for bone grafting, shortens treatment times, and reduces morbidity. They have also been used in patients with maxillectomies resulting from tumors or diseases associated with atrophic conditions of the maxilla.

OrthodonticsTitanium implantbusiness.industrymedicine.medical_treatmentBone graftingmedicine.diseaseAtrophyImmediate loadingMaxillaMedicineIn patientbusinessPosterior maxillaDental alveolus
researchProduct

Diagnosis and Planning in Immediate Loading: Prosthetic Diagnosis

2019

Immediate loading provides functional and esthetic advantages, improving the quality of life of the patient during the osseointegration period. But, clinicians have to know that the three key parameters that should be evaluated for prosthetic planning of the totally edentulous patient are prosthetic space, lip support, and smile line. This is a crucial part of the planning because the prosthetic space, lip support, and smile line determine the type of prosthetic restoration.

Orthodonticsbusiness.industryImmediate loadingMedicinebusinessEdentulous patient
researchProduct

Immediate Loading in All-on-Four

2019

Severe bone atrophy of the upper maxilla (Cawood and Howell class V and VI) is associated with certain problems such as reduced perioral tissue support, the impossibility of wearing complete dentures, chewing and speech alterations, and difficulties in placing dental implants due to the limited amount of available bone.

Orthodonticsbusiness.industrymedicine.medical_treatmentmedicine.diseasestomatognathic diseasesAtrophystomatognathic systemImmediate loadingMaxillaMedicineAll on fourDenturesbusinessSurvival rate
researchProduct

IMI – Oral biopharmaceutics tools project – Evaluation of bottom-up PBPK prediction success part 2: An introduction to the simulation exercise and ov…

2016

Orally administered drugs are subject to a number of barriers impacting bioavailability (Foral), causing challenges during drug and formulation development. Physiologically-based pharmacokinetic (PBPK) modelling can help during drug and formulation development by providing quantitative predictions through a systems approach. The performance of three available PBPK software packages (GI-Sim, Simcyp®, and GastroPlus™) were evaluated by comparing simulated and observed pharmacokinetic (PK) parameters.Since the availability of input parameters was heterogeneous and highly variable, caution is required when interpreting the results of this exercise. Additionally, this prospective simulation exer…

Physiologically based pharmacokinetic modellingChemistryBiopharmaceuticsDrug Evaluation PreclinicalArea under the curveAdministration OralPharmaceutical ScienceModels Biological030226 pharmacology & pharmacyBiopharmaceuticsBioavailabilityClinical studyToxicology03 medical and health sciences0302 clinical medicineIntestinal AbsorptionPharmaceutical PreparationsPharmacokineticsCompounding030220 oncology & carcinogenesisStatisticsHumansComputer SimulationImmediate releaseForecastingEuropean Journal of Pharmaceutical Sciences
researchProduct

Predicting Pharmacokinetics of Multisource Acyclovir Oral Products Through Physiologically Based Biopharmaceutics Modeling.

2021

Abstract Highly variable disposition after oral ingestion of acyclovir has been reported, although little is known regarding the underlying mechanisms. Different studies using the same reference product (Zovirax ®) showed that Cmax and AUC were respectively 44 and 35% lower in Saudi Arabians than Europeans, consistent with higher frequencies of reduced-activity polymorphs of the organic cation transporter (OCT1) in Europeans. In this study, the contribution of physiology (i.e., OCT1 activity) to the oral disposition of acyclovir immediate release (IR) tablets was hypothesized to be greater than dissolution. The potential role of OCT1 was studied in a validated physiologically-based biopharm…

Physiologically based pharmacokinetic modellingIn vitro dissolutionChemistryBiopharmaceuticsCmaxPharmaceutical ScienceAcyclovirBioequivalencePharmacologyBiopharmaceuticsOral ingestionPharmacokineticsSolubilityTherapeutic EquivalencyImmediate releaseTabletsJournal of pharmaceutical sciences
researchProduct

Implant loss and crestal bone loss in early loading versus delayed and immediate loading in edentulous mandibles. A systematic review and meta-analys…

2021

Background Information about the risk of early loss and crestal bone loss of dental implants which have been loaded early is scant if compared with data available for those conventionally or immediately loaded. A meta-analysis of early loss and crestal bone loss in immediate or delayed loaded full mandibular denture retaining dental implants has been recently published. It is interesting to evaluate also the risks of early versus immediate and delayed loading in complete mandibular restorations. The purpose of this systematic review and meta-analysis was to study early (EL) versus immediate (IL) and delayed loading (DL) protocols in edentulous mandibles to determine whether differences exis…

Prosthetic DentistryCrestal bonebusiness.industrymedicine.medical_treatmentDentistryReview030206 dentistrylaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawImmediate loadingMeta-analysisEarly loadingmedicine030212 general & internal medicineImplantbusinessDental implantGeneral DentistryUNESCO:CIENCIAS MÉDICASDental alveolusJournal of Clinical and Experimental Dentistry
researchProduct

Immediate prosthesis over implants retained using abutments with flexible screws: A preliminary study

2017

Background Immediate loading protocols for the rehabilitation of edentulous or partially edentulous patients have become very popular, due to the conveniences they afford in comparison with conventional loading techniques. Material and Methods A preliminary study was carried out with 8 patients subjected to dental implant treatment with an immediate loading protocol involving a novel system of abutments with flexible screws. Implant survival was analyzed, together with marginal bone loss and patient and dentist satisfaction. Results A total of 35 implants were subjected to immediate loading using the abutments with flexible screws. The mean patient and dentist satisfaction score was 9.1 and…

Prosthetic Dentistrybusiness.industryResearchmedicine.medical_treatment0206 medical engineeringDentistry030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringProsthesis03 medical and health sciences0302 clinical medicineImmediate loadingUNESCO::CIENCIAS MÉDICASMedicineImplantbusinessDental implantGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct