From Feynman–Kac formulae to numerical stochastic homogenization in electrical impedance tomography
2016
In this paper, we use the theory of symmetric Dirichlet forms to derive Feynman–Kac formulae for the forward problem of electrical impedance tomography with possibly anisotropic, merely measurable conductivities corresponding to different electrode models on bounded Lipschitz domains. Subsequently, we employ these Feynman–Kac formulae to rigorously justify stochastic homogenization in the case of a stochastic boundary value problem arising from an inverse anomaly detection problem. Motivated by this theoretical result, we prove an estimate for the speed of convergence of the projected mean-square displacement of the underlying process which may serve as the theoretical foundation for the de…
On the variations of acoustic absorption peak with particle velocity in micro-perforated panels at high level of excitation.
2010
The acoustic behavior of micro-perforated panels (MPP) is studied theoretically and experimentally at high level of pressure excitation. A model based on Forcheimer's regime of flow velocity in the perforations is proposed. This model is valid at relatively high Reynolds numbers and low Mach numbers. The experimental method consists in measuring the acoustical pressure at three different positions in an impedance tube, the two measurement positions usually considered in an impedance tube and one measurement in the vicinity of the rear surface of the MPP. The impedance tube is equipped with a pressure driver instead of the usual loudspeaker and capable of delivering a high sound pressure lev…
Acoustic characterization of Silica aerogel clamped plates for perfect absorption purpose
2017
International audience; Silica aerogel has been widely studied as bulk material for its extremely low density and thermal conductivity. Plates or membranes made of this extremely soft materials exhibits interesting properties for sound absorption. A novel signal processing method for the characterization of an acoustic metamaterial made of silica aerogel clamped plates is presented. The acoustic impedance of a silica aerogel clamped plate is derived from the elastic theory for the flexural waves, while the transfer matrix method is used to model reflection and transmission coefficients of a single plate. Experimental results are obtained by using an acoustic impedance tube. The difference b…
Technical Note: Prediction Models of Airborne Sound Insulation of Multilayer Materials with Viscoelastic Thin Sheets
2008
The growing introduction of new insulation materials in building acoustics has caused an increase of the importance of the prediction tools. Appropriate simulations allow strictly necessary laboratory measurements to be identified. In this way, costs are reduced. The demands of new legislation has resulted in the appearance of various software designed to facilitate prediction. The prediction models are based on different hypotheses: adaptation of impedances, spatial behaviour of spectral components, statistical energy distribution, the Finite Element Method (FEM), etc. Each of these models and methods offer advantages and contain limitations. In this paper, different models for prediction…
Trap-limited mobility in space-charge limited current in organic layers
2009
Space-charge limited current transport in organic devices, relevant to the operation of a range of organic optoelectronic devices, is analyzed in the frequency domain. The classical multiple trapping picture with one transport state and one trap level is used as the basis for the descriptions. By varying the energetic and kinetic properties of the traps, we show that the admittance and the capacitance spectra are considerably modified depending on the interplay between the trap-limited mobility and the trap kinetics. We point out that capacitance steps at low-frequency, usually found in experiments, are observed only for slow traps. © 2008 Elsevier B.V. All rights reserved.
Physicochemical characterization of passive films on niobium by admittance and electrochemical impedance spectroscopy studies
2005
An analysis of the electronic properties of amorphous semiconductor-electrolyte junction is reported for thin (D ox < 20 nm) passive film grown on Nb in acidic electrolyte. It will be shown that the theory of amorphous semiconductor-electrolyte junction (a-SC/EI) both in the low band-bending and high band-bending regime is able to explain the admittance data of a-Nb 2 O 5 /El interface in a large range (10 Hz-10 kHz) of frequency and electrode potential values. A modelling of experimental EIS data at different potentials and in the frequency range of 0.1 Hz-100 kHz is presented based on the theory of amorphous semiconductor and compared with the results of the fitting of the admittance data…
On the use of the electromechanical impedance technique for the assessment of dental implant stability: Modeling and experimentation
2014
We propose the electromechanical impedance technique to monitor the stability of dental implants. The technique consists of bonding one wafer-type piezoelectric transducers to the implant system. When subjected to an electric field, the transducer induces structural excitations which, in turn, affect the transducer’s electrical admittance. The hypothesis is that the health of the bone surrounding the implant affects the sensor’s admittance. A three-dimensional finite element model of a transducer bonded to the abutment of a dental implant placed in a host bone site was created to simulate the progress of the tissue healing that occurs after surgery. The healing was modeled by changing the …
Comparison of bipolar and tetrapolar impedance techniques for assessing fat mass.
2004
Whole body fat mass (BF) can be predicted by different bioimpedance (BIA) techniques measuring the whole body (tetrapolar hand-to-foot technique, HF), lower body (bipolar foot-to-foot technique, FF), or upper body (bipolar hand-to-hand technique, HH). This study analyzed 146 healthy volunteers (age 18-84 years) for whether these three techniques differ in their estimates of BF, and whether sex and age of the subjects influence estimates of BF. Reproducibility of the techniques was tested by calculating the technical error (TE). Effects of BIA technique, sex, and age on predicted BF were analyzed with ANOVA for repeated measurements in a mixed effect design. Results showed high reproducibili…
Bioelectrical characteristics of type 1 and type 2 diabetic subjects with reference to body water compartments.
1998
Since bioelectrical characteristics correspond well to body water compartments, this study investigated bioelectrical differences between type 1 and type 2 diabetic subjects that could reflect differences in body water compartments. We investigated cross-sectionally 612 adult subjects, classified into 10 groups according to sex and disease (control, obese normal glucose tolerant, non-obese type 2 diabetes, obese type 2 diabetes, type 1 diabetes). Resistance (R), reactance (Xc) and phase angle (PA) were measured (800 microA - 50 kHz alternating current). The bioelectrical vector was obtained by plotting R and Xc normalized for height (ht), it is easily identified on the basis of the length (…
Growth hormone replacement in adults:Real-world data from two large studies in US and Europe
2020
Objective: This report describes the effectiveness and safety of growth hormone replacement in 3180 adult patients with growth hormone deficiency followed-up for 0.0–12.2 years in two completed, complementary, non-interventional, multicentre studies, NordiNet® International Outcome Study (IOS) (NCT00960128) and the American Norditropin® Studies: Web-Enabled Research (ANSWER) Program (NCT01009905). Design: In both studies, Norditropin® (somatropin; Novo Nordisk A/S, Denmark) was administered at the discretion of the treating physician and according to routine practice. We present data on baseline characteristics, growth hormone dose, safety data and change from baseline in waist circumferenc…