Search results for "Implantable"
showing 10 items of 60 documents
Therapeutic management in Sicilian patients with definite arrhythmogenic right ventricular dysplasia/cardiomyopathy and focus on the role of implanta…
2014
Arrhythmogenic Right Ventrticular Dysplasia/Cardiomyopathy(ARVD/C) is an inherited cardiomyopathy characterized by right ven-tricularmyocytelosswithfibrofattyreplacement,ahighriskofventric-ular arrhythmias (VA) and sudden cardiac death (SCD) [1]. Preventionof SCD represents the most important management strategy and theachievement of this target can be reached by different therapeuticstrategies including implantable cardioverter-defibrillator (ICD)implantation, pharmacologic therapy, catheter ablation of ventriculartachycardia (VT) and cardiac transplantation [2,3]. The aim of thisstudy is to examine the outcome of the different therapies adopted ina group of affected patients, focusing on th…
Optimal Response to Cardiac Arrest study: Defibrillation waveform effects
2001
Abstract Introduction: Advances in early defibrillation access, key to the “Chain of Survival”, will depend on innovations in defibrillation waveforms, because of their impact on device size and weight. This study compared standard monophasic waveform automatic external defibrillators (AEDs) to an innovative biphasic waveform AED. Material and methods: Impedance-compensated biphasic truncated exponential (ICBTE) and either monophasic truncated exponential (MTE) or monophasic damped sine (MDS) AEDs were prospectively, randomly assigned by date in four emergency medical services. The study design compared ICBTE with MTE and MDS combined. This subset analysis distinguishes between the two clas…
Cardiac arrhythmias in patients with Danon disease.
2016
Aims Different cardiac arrhythmias have been suggested to be associated with Danon disease, e.g. Wolff–Parkinson–White syndrome. However, a systematic electrophysiological investigation of patients with Danon disease is lacking thus far. Methods and results Seven patients with Danon disease (4 males, 35.8 ± 10.8 years; 3 females, 51.3 ± 19.9 years) from 3 different families were studied. In all patients, the presence of Danon disease was confirmed by western blot of biopsy material or genetic testing. The patients were characterized by 12-lead electrocardiogram (ECG), Holter ECG, echocardiography, and serial implantable cardioverter defibrillator (ICD) interrogations (in ICD recipients). Al…
Lead-Related Infective Endocarditis in Latvia: A Single Centre Experience
2019
Background and Objectives: Over the last five decades cardiac implantable electronic devices (CIED) have become established as the mainstay for the treatment of permanent bradycardias, chronic heart failure and dangerous heart rhythm disturbances. These devices improve survival and quality of life in many patients. However, infections associated with CIED implantation, particularly lead-related infective endocarditis (LRIE), can offset all benefits and make more harm than good for the patient. To date, there are no other studies in Latvia, addressing patients with lead-related infective endocarditis. The objective of this study was to identify the most common pathogens associated with LRIE …
Nemaline myopathy and heart failure: role of ivabradine; a case report
2015
Background Nemaline myopathy (NM) is a rare congenital myopathy characterized by muscle weakness, hypotonia and the presence in muscle fibers of inclusions known as nemaline bodies and a wide spectrum of clinical phenotypes, ranging from severe forms with neonatal onset to asymptomatic forms. The adult-onset form is heterogeneous in terms of clinical presentation and disease progression. Cardiac involvement occurs in the minority of cases and little is known about medical management in this subgroup of NM patients. We report a rare case of heart failure (HF) in a patient with adult-onset NM in whom ivabradine proved to be able to dramatically improve the clinical picture. Case presentation …
Collagen copolymer posterior chamber phakic intraocular lens for hyperopia correction: three-year follow-up.
2013
Purpose To assess the efficacy, predictability, safety, and stability of the Visian V3 Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) for moderate to high hyperopia. Setting Private clinic, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, endothelial cell density, intraocular pressure (IOP), central vault, and adverse events were evaluated for 3 years postoperatively. Results The study comprised 73 eyes of 44 patients. The mean spherical equivalent decreased from +4.84 diopters (D) ± 1.6 (SD) (range +1.00 to +7.75 D) preoperatively to −0.13 ± 0.39 …
Comparative analysis in terms of computational cost for different discrimination algorithms in implantable defibrillators
2005
Implantable defibrillators (ICDs) use very low computational cost criteria (rate, stability and onset) offering good sensitivity for arrhythmia detection. Although, the specificity of these combined criteria decreases in difficult arrhythmia discrimination as in case of discrimination between ventricular tachycardia (VT) and supraventricular tachycardia (SVT). Several morphological published algorithms enhance arrhythmia discrimination but most algorithms are developed in personal computers and cannot be used in ICDs because of computational cost requirements compared with limited ICD capabilities. A general method to determine the possibility of ICD implementation for a discrimination algo…
Managed ventricular pacing vs. conventional dual-chamber pacing for elective replacements: the PreFER MVP study: clinical background, rationale, and …
2008
Udgivelsesdato: 2008-Mar AIMS: Several clinical studies have shown that, in patients with intact atrioventricular (AV) conduction, unnecessary chronic right ventricular (RV) pacing can be detrimental. The managed ventricular pacing (MVP) algorithm is designed to give preference to spontaneous AV conduction, thus minimizing RV pacing. The clinical outcomes of MVP are being studied in several ongoing trials in patients undergoing a first device implantation, but it is unknown to what extent MVP is beneficial in patients with a history of ventricular pacing. The purpose of the Prefer for Elective Replacement MVP (PreFER MVP) study is to assess the superiority of the MVP algorithm to convention…
Feasibility, limitations and potentiality of UHF-RFID passive implants
2012
Implanted RFID may play an important role in the personal Healthcare of next future. Antenna embedded into prosthesis or into other implanted medical devices could permit to monitor physiological and pathological processes, providing a natural interconnection to remote services. The big technical challenge is to establish a stable RFID link with the interior of the human body in spite of the high electromagnetic losses of the tissues. By using parametric electromagnetic models and some early result, it is here investigated the potentiality and limitation of the UHF implants with special attention to the body district, the overall mass, and the size of the antennas.
A New Tool for the Analysis of the Effect of Intracerebrally Injected Anti-Amyloid-β Compounds
2021
Background: A wide range of techniques has been developed over the past decades to characterize amyloid-β (Aβ) pathology in mice. Until now, no method has been established to quantify spatial changes in Aβ plaque deposition due to targeted delivery of substances using ALZET® pumps. Objective: Development of a methodology to quantify the local distribution of Aβ plaques after intracerebral infusion of compounds. Methods: We have developed a toolbox to quantify Aβ plaques in relation to intracerebral injection channels using Zeiss AxioVision® and Microsoft Excel® software. For the proof of concept, intracerebral stereotactic surgery was performed in 50-day-old APP-transgenic mice injected wit…