Search results for "Implantable"
showing 10 items of 60 documents
Sacubitril/valsartan reduces indications for arrhythmic primary prevention in heart failure with reduced ejection fraction: insights from DISCOVER-AR…
2021
Abstract Aims This sub-study deriving from a multicentre Italian register [Deformation Imaging by Strain in Chronic Heart Failure Over Sacubitril-Valsartan: A Multicenter Echocardiographic Registry (DISCOVER)-ARNI] investigated whether sacubitril/valsartan in addition to optimal medical therapy (OMT) could reduce the rate of implantable cardioverter-defibrillator (ICD) indications for primary prevention in heart failure with reduced ejection fraction (HFrEF) according to European guidelines indications, and its potential predictors. Methods and results In this observational study, consecutive patients with HFrEF eligible for sacubitril/valsartan from 13 Italian centres were included. Lack o…
Improved method for cannula fixation for long-term intracerebral brain infusion
2017
Abstract Background Implanted osmotic minipumps are commonly used for long-term, brain-targeted delivery of a wide range of experimental agents by being connected to a catheter and a cannula. During the stereotactical surgery procedure, the cannula has to be placed correctly in the x-y directions and also with respect to the injection point in the z-direction (deepness). However, the flat fixation base of available cannula holders doesn’t allow an easy, secure fixation onto the curve-shaped skull. New method We have developed a modified method for a better fixation of the cannula holder by using an easy-to-produce, skull-shaped silicone spacer as fixation adapter. Results We describe the ap…
Implantation of a biventricular defibrillator in a borderline case of arrhythmogenic right ventricular dysplasia/cardiomyopathy
2014
European Clinical Experience with a Dual Chamber Single Pass Sensing and Pacing Defibrillation Lead
2002
Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of…
Posterior‐chamber phakic implantable collamer lenses with a central port: a review
2020
Abstract We aimed to summarize the outcomes reported following the implantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc) for myopia correction. A literature search in PubMed, Web of Science and Scopus was carried out to identify publications reporting clinical outcomes of patients who were implanted with the V4c ICL model and had a follow‐up period of at least 6 months. A total of 35 clinical studies published between 2012 and 2020 were included in the present review. A comprehensive analysis of the available data was performed, focusing on visual and refractive outcomes at different time‐points post‐surgery. In addition, adverse events and other pa…
Patient Alert to detect ICD lead failure: efficacy, limitations, and implications for future algorithms.
2006
Aims An algorithm that alerts implantable cardioverter-defibrillator (ICD) patients, in case of abnormal lead impedance (Patient Alert™, Medtronic), may help to recognize lead dysfunction. We aimed to determine the utility of Patient Alert for ICD lead-failure detection in a prospective study. Methods and results Three hundred and sixty ICD patients were followed for 22±14 months. Patient Alert was active for pacing impedance 2000–3000 Ω, and high-voltage conductor impedance 200 Ω. Ten alert events and a total of 29 severe system complications occurred. Patient Alert detected three of 10 ICD lead failures, with a positive predictive value (PPV) of 77.8% for any severe system complication. R…
Is there a right place to pace the right ventricle? Evaluation of apical and septal positions in a pacemaker population: Study protocol for a prospec…
2014
Abstract Introduction The main objective of research in pacemaker therapy has been to provide the best physiologic way to pace the heart. Despite the good results provided by right ventricular pacing minimization and by biventricular pacing in specific subsets of heart failure patients, these options present many limitations for standard pacemaker recipients. In these patients, pacing the right ventricle at alternative sites could result in a lower degree of left intraventricular dyssynchrony. Despite the lack of strong evidence and the difficulty in placing and accurately classifying the final lead position, pacing at alternative right ventricular sites seems to have become a standard proc…
Continuous intra-amygdalar infusion of GABA in the amygdala kindling model of epilepsy in rat.
2003
Objective: To explore the effect of continuous intra-amygdalar infusion of GABA in the amygdala kindling model of epilepsy in rat. Methods: An electrode and cannula complex was implanted in adult male Wistar rats, the electrode being targeted to the left basolateral amygdala. The animals were subjected to a standard kindling procedure. Osmotic minipumps filled with either GABA or mannitol were connected to cannulas and allowed to infuse during 7 days. Kindling experiments measuring after-discharge and seizure thresholds, seizure severity and duration, and behavioral toxicity were performed before, during and after the drug infusion period. Results: Both after-discharge and seizure threshold…
Prophylactic Implantable Cardioverter Defibrillator Placement in a Sporadic Desmin Related Myopathy and Cardiomyopathy
2004
Desminopathy is a neuromuscular disorder associated with the accumulation of the protein desmin. This article reports a case of a man with a mutation in the desmin gene suffering from cardiomyopathy and skeletal myopathy. This patient underwent implantable cardioverter defibrillator (ICD) implantation for prognostic considerations and subsequently developed a sustained ventricular tachycardia (SVT). While nonsustained VTs (NSVT) have previously been reported, this is the first time that a SVT could be seen in a patient with this disease.
ICD Implantation in infants and small children: the extracardiac technique.
2007
There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…