Search results for "Inductively coupled plasma"
showing 10 items of 188 documents
Control of matrix interferences by multiple linear regression models in the determination of arsenic and lead concentrations in fly ashes by inductiv…
2010
A multiple linear regression technique was used to evaluate and correct the matrix interferences in the determination of As and Pb concentrations in fly ashes by inductively coupled plasma optical emission spectrometry. The direct determination of As and Pb in SRM 1633b by ICP-OES failed to obtain the certified concentrations, except in a couple of cases. However, it proved possible to use the multiple linear regression (MLR) technique to correct the determined concentrations to a satisfactory level. This method of correction is based on the multiple regression line obtained from the analysis of 19 synthetic mixtures of matrix and analyte elements (Al, As, Ca, Fe, Pb, and Si) at five concen…
First experimental proof of asymmetric charge transfer in ICP-MS/MS (ICP-QQQ-MS) through isotopically enriched oxygen as cell gas
2014
The quantification of a variety of elements in the field of ICP-MS is restricted by isobaric interferences. The recent development of ICP-MS/MS (“triple quadrupole” configuration) offers a new way to solve the problem of the detection of such elements affected by interferences because the signal caused by either the analyte or the isobaric interference can be shifted to another m/z through reactions with the cell gas (oxygen, ammonia or hydrogen). This system consists of two quadrupoles (Q1 and Q2) with a collision/reaction cell in between. When using the MS/MS mode of this configuration it becomes possible to restrict the ions entering the cell to a defined m/z and therefore get a better i…
Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold
2021
Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…
Trace elemental composition of curry by inductively coupled plasma optical emission spectrometry (ICP-OES)
2008
A methodology based on inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion was developed to determine the content of traces elements in curry samples from the Spanish market. The methodology was validated in terms of accuracy by the analysis of citrus and tomato leaf reference materials achieving comparable results with the certified values. The trace metal content of curry samples was compared with data available from previously published reports concerning Indian samples, especially in terms of heavy metal composition, in order to guarantee the quality of the commercially available spices in the European countries. Values found for th…
Optimization of operating conditions of axially and radially viewed plasmas for the determination of trace element concentrations from ultrasound-ass…
2006
Abstract The method of ultrasound-assisted extraction followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element concentrations (arsenic, copper, lead, antimony, and zinc) in shooting range areas was optimized. Optimization was achieved not only on the basis of the analysis of appropriate standard reference materials but also on that of 31 synthetic mixtures of matrix and analyte elements (aluminum, antimony, arsenic, calcium, copper, lead, iron, manganese, silicon, and zinc), in five concentrations. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg II 280.270 nm/Mg I 285.213 …
The determination of antimony and arsenic concentrations in fly ash by hydride generation inductively coupled plasma optical emission spectrometry
2011
Abstract Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) was used in the determination of As and Sb concentrations in fly ash samples. The effect of sample pre-treatment reagents and measurement parameters used for hydride generation was evaluated. Due to memory effects observed, the appropriate read delay time was adjusted to 60 s resulting in RSDs 0.6% and 2.3% for As and Sb, respectively. The most suitable volumes of pre-reduction reagents for 10 mL of sample were 4 mL of KI/ascorbic acid (5%) and 6 mL of HCl (conc.). The determination of Sb was significantly interfered by HF, but the interference could be eliminated by adding 2 mL of saturated bo…
PHYSICO-CHEMICAL CHARACTERIZATION OF THE ACQUALADRONE ROSTRUM
2011
The archaeological discovery of the Acqualadrone rostrum (an offensive naval weapon mounted on the prow at the waterline), off the Italian coast near Messina in 2008, has led to the need for scientific research in order to plan the conservation treatment of this artefact. The discovery is exceptional because of the presence of a wooden section from the original ship. This paper describes the physico-chemical characterization of a metallic and two wooden samples by inductively coupled plasma – optical emission spectroscopy, inductively coupled plasma – mass spectrometry, Fourier transform infrared spectroscopy, 13 C{ 1 H} cross-polarization magic angle spinning NMR spectroscopy, energy-dispe…
Biological mineral content in Iberian skeletal cremains for control of diagenetic factors employing multivariate statistics
2013
Abstract The aim of this study was to define a strategy for a correct selection of bone samples by employing inductively coupled plasma optical emission spectroscopy (ICP-OES) for reconstructing the biological mineral content in bones through the determination of major elements, trace elements and Rare Earth Elements (REE, lanthanides) in skeletal cremains of ancient Iberians (III–II B.C), discovered in the Necropolis of Corral de Saus (Moixent, Valencia) between 1972 and 1979. The biological mineral content was determined taking into account diagenetic factors. A control method for a better reading of results was applied. To explore large geochemical datasets and to reduce the number of va…
Hair Mercury Levels Detection in Fishermen from Sicily (Italy) by ICP-MS Method after Microwave-Assisted Digestion
2015
A number of ninety-six hair samples from Sicilian fishermen were examined for total mercury detection by an Inductively Coupled Plasma Mass Spectrometry (ICP-MS) method. The mercury levels obtained were compared with mercury levels of 96 hair samples from a control group, in order to assess potential exposure to heavy metals of Sicilian fishermen due to fish consumption and closeness to industrial activities. Furthermore, the mercury levels obtained from hair samples were sorted by sampling area in order to verify the possible risks linked to the different locations. The overall mean concentration in the hair of the population of fishermen was6.45±7.03 μg g−1, with a highest value in a fish…
Speciation of Sb in airborne particulate matter, vehicle brake linings, and brake pad wear residues
2013
Insights into the speciation of Sb in samples of brake linings, brake pad wear residues, road dust, and atmospheric particulate matter PM10 and PM2.5 were obtained combining several well established and advanced characterization techniques, such as scanning electron microscopy e energy dispersive spectrometry (SEM-EDS), inductively coupled plasma mass spectrometry (ICP-MS) and synchrotron radiation X-ray absorption spectroscopy (SR-XAS). The advantage of SR-XAS is that samples do not undergo any chemical treatment prior to measurements, thus excluding possible alterations. These analyses revealed that the samples of wheel rims dust, road dust, and atmospheric particulate matter are composed…