Search results for "Instrument"
showing 10 items of 5652 documents
PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables
2022
Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studi…
Distribution and projections of nitric oxide synthase neurons in the rodent superior olivary complex.
2000
The superior olivary complex (SOC), a group of interrelated brainstem nuclei, sends efferents to a variety of neuronal structures including the cochlea and the inferior colliculus. The present review describes data obtained from rodents providing evidence that the gaseous, short-living neuroactive substance nitric oxide (NO) is produced in the SOC. The NO-synthesizing enzyme neuronal NO-synthase (nNOS) has been localized by means of several methods including histochemistry and immunohistochemistry. Perikarya containing nNOS were found in several nuclei of the SOC. Their largest numbers and percentages of total cells were observed in the medial nucleus of the trapezoid body. Stained terminal…
Studies of structural composition distribution heterogeneity in ethylene/1-hexene copolymers using thermal fractionation technique (SSA)
2005
Abstract Investigations into the compositional heterogeneity of ethylene/1-hexene copolymers obtained with various zirconocene/MAO catalysts, either homogeneous or supported on inorganic carriers such as a complex of magnesium chloride with tetrahydrofuran or methyl alcohol, were conducted. The dependence between metallocene structure, as well as catalyst immobilization, and the compositional heterogeneity of the related products was investigated. It was found that the heterogeneity of copolymers is determined by the metallocene catalyst structure. The amount of peaks on the DSC thermograms of copolymers and their division increase with the increase of bulkiness of the ligand in the catalyt…
Optical Properties of Irradiated Yttrium Aluminum Garnet
2012
The results of investigation of the photoluminescence (PL) and optical absorption of crystals Y3Al5O12(YAG) doped with different concentrations of manganese ions exposed to fast neutron irradiation and electron irradiation are presented. Photoluminescence spectra of YAG before neutron irradiation at T=80 K contain fine lines in orange region of spectrum, ascribed to Mn2+ ions in octahedral position. After irradiation band broadening is observed in the luminescence spectra of garnet crystals. Electron irradiation produced broad band with a complex structure related to Mn4+ ions. Exchange interaction between radiation defect and impurity ions during neutron irradiation and electron irradiatio…
The study of time-resolved absorption and luminescence in PbWO4 crystals
2000
Abstract The transient absorption and luminescence under pulsed electron beam excitation were studied for undoped and La3+ doped PbWO4 crystals. The absorption band at ∼1.0 eV is suggested to be due to self-trapped electrons and the absorption band at 3.5 eV may be due to self-trapped holes. The formation of luminescence centers via electron–hole recombination is affected by La3+ in doped crystals. The large fraction of electrons and holes undergoes thermostimulated recombination within geminate pairs and the spatial separation of geminate pairs components is important in recombination process. The intrinsic (blue) luminescence arises in this recombination. The mechanism of La3+ influence o…
Neutron flux and gamma dose measurement in the BNCT irradiation facility at the TRIGA reactor of the University of Pavia
2018
Abstract University of Pavia is equipped with a TRIGA Mark II research nuclear reactor, operating at a maximum steady state power of 250 kW. It has been used for many years to support Boron Neutron Capture Therapy (BNCT) research. An irradiation facility was constructed inside the thermal column of the reactor to produce a sufficient thermal neutron flux with low epithermal and fast neutron components, and low gamma dose. In this irradiation position, the liver of two patients affected by hepatic metastases from colon carcinoma were irradiated after borated drug administration. The facility is currently used for cell cultures and small animal irradiation. Measurements campaigns have been ca…
The effect of oxygenation on the radiation hardness of silicon studied by surface photovoltage method
2002
The effect of oxygenation on the radiation hardness of silicon detectors was studied. Oxygen-enriched and standard float-zone silicon pin-diodes and oxidized samples were processed and irradiated with 15-MeV protons. After the irradiations, the surface photovoltage (SPV) method was applied to extract minority carrier diffusion lengths of the silicon samples. Adding oxygen to silicon was found to improve the radiation hardness of silicon. The effect was visible in minority carrier diffusion lengths as well as in reverse bias leakage currents. The suitability of SPV method for characterizing irradiated silicon samples was proved.
A measurement of the neutron to 199Hg magnetic moment ratio
2014
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result γn/γHg=3.8424574(30).
Annealing study of oxygenated and non-oxygenated float zone silicon irradiated with protons
2003
Abstract Introducing oxygen into the silicon material is believed to improve the radiation hardness of silicon detectors. In this study, oxygenated and non-oxygenated silicon samples were processed and irradiated with 15 MeV protons. In order to speed up the defect reactions after the exposure to particle radiation, the samples were heat treated at elevated temperatures. In this way, the long-term stability of silicon detectors in hostile radiation environment could be estimated. Current–voltage measurements and Surface Photovoltage (SPV) method were used to characterize the samples.
Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz
2010
To establish Boron Neutron Capture Therapy (BNCT) for non-resectable liver metastases and for in vitro experiments at the TRIGA Mark II reactor at the University of Mainz, Germany, it is necessary to have a reliable dose monitoring system. The in vitro experiments are used to determine the relative biological effectiveness (RBE) of liver and cancer cells in our mixed neutron and gamma fi eld. We work with alanine detectors in combination with Monte Carlo simulations, where we can measure and characterize the dose. To verify our calculations we perform neutron fl ux measurements using gold foil activation and pin-diodes . Material and methods . When L- α -alanine is irradiated with ionizing …