Search results for "Instrument"
showing 10 items of 5652 documents
A new resonant Laser-SNMS system for environmental ultra-trace analysis: Installation and optimization
2017
Abstract Localization, analysis and mobility of radioactive contaminated particles is of major concern for assessment of contamination threads and nuclear forensics. For this purpose, a new resonant Laser-SNMS system was developed and set up at the Institute for Radioecology and Radiation Protection for spatially resolved ultra-trace analysis of low concentrated radionuclides directly on environmental samples. This paper describes the adaption and combination of a dedicated Ti:sapphire laser system with a commercial TOF-SIMS instrument for resonant Laser-SNMS. The project includes computer simulations for optimization of the TOF analyzer. Results on synthetic uranium and technetium samples …
New applicator improves waterjet dissection quality
2010
Waterjet dissection is accomplished with Helix Hydro-Jet, but a new device with improved operative handling and potentially superior dissection qualities has been developed.Eighty-four fresh cadaveric pig brains were simultaneously cut with Helix Hydro-Jet and Erbejet 2. A commonly used applicator and a new applicator for the Helix Hydro-Jet were directly compared to the new Erbejet 2. Under standardised conditions, different pressure levels were applied to the brain surface without arachnoids. Technical features, cutting depth, tissue damage and differences of applicators were examined.Microscopic analysis of cutting depth revealed different dissection characteristics of both the devices. …
Pedobarography: A Review on Methods and Practical Use in Foot Disorders
2021
Pedobarographic examination is a non-invasive method that enables the quantitative and qualitative evaluation of plantar pressure distribution, notably the plantar pressure distribution, referring to the function of the entire musculoskeletal system. This is a scoping review that aims to update knowledge on the practical use of pedobarography in foot disorders. We also attempted to systematize the methodological principles of conducting the pedobarographic examination. We searched Medline/PubMed, Embase, Web of Science, and the Cochrane Database of Systematic Reviews for the articles on the methodology of pedobarography. The search encompassed clinical trials, randomized controlled trials, …
Modification of Angular Kinematics and Spatiotemporal Parameters during Running after Central and Peripheral Fatigue
2021
Fatigue causes kinematics modifications during running, and it could be related to injuries. The aim was to identify and compare the effects of central and peripheral fatigue on angular kinematics and spatiotemporal parameters during running. Angular kinematics and spatiotemporal parameters were evaluated using an infrared motion capture system and were registered during 2 min treadmill running in pre- and post-fatigue states in eighteen male recreational runners. Central fatigue was induced by a 30 min running fatigue protocol on a treadmill, while peripheral fatigue in quadriceps and hamstrings muscles was induced by an isokinetic dynamometer fatigue protocol. Central fatigue increased th…
The use of a new kind of low profile retractor for arteriovenous fistula procedure simplifies and speeds up the intervention
2009
Purpose The aim of this study was to demonstrate the effectiveness of a new kind of disposable surgical retractor in arteriovenous fistula (AVF) procedures in order to achieve an easier, faster and safer surgical intervention. Methods Between January and June 2008, 22 AVF procedures were performed using the 3PAWS ReeTrakttrade; (Insightra Inc. - Irvine, Ca., USA) a self-retaining, low profile retractor. An equivalent patient sample, in which an AVF was performed using conventional retraction devices, was considered for comparison of the intra- and post-operative results. Results In all of the 22 AVF procedures performed, the ReeTrakt™ system has simplified the performance of the surgical te…
Changes in Pelvic Floor Muscle Tone after ‘Jumping Fitness’ Training—A Case Stud
2021
Aims Previous studies confirm the existence of a beneficial component of mechanical vibration and oscillation during trampoline exercises. Researchers have been interested in the possibility of using these exercises in the process of strengthening pelvic floor muscles and in cases of stress urinary incontinence. This study aimed to evaluate changes in pelvic floor muscle tone after 8 weeks of systematic ‘jumping fitness’ training and performing a follow-up observation of the maintenance of this effect after 9 months. Case report This study involved a young woman without symptoms of stress urinary incontinence who began practicing ‘jumping fitness’ 3 times a week for 2 months. After the end …
Electrochemical detection and screening of bladder cancer recurrence using direct electrochemical analysis of urine: A non-invasive tool for diagnosis
2018
Although detection of urothelial cell carcinoma (or bladder cancer, BC) can be performed via cytological, molecular and genetic marker tests on urine, cystoscopy, an invasive technique, still remains as the gold methodology in clinical practice. It is presented a non-invasive method for detecting BC recurrence consisting of a direct electrochemical test in urine combining voltammetric data at gold and glassy carbon electrodes. The diagnosis is based on the ratio between characteristic voltammetric features recorded for tryptophan, serotonin and melatonin and other related metabolites. The method was tested by means of a clinical trial with 30 patients diagnosed of bladder cancer and a two c…
2020
Gait variability observed in step duration is predictive of impending adverse health outcomes among apparently healthy older adults and could potentially be evaluated using wearable sensors (inertial measurement units, IMU). The purpose of the present study was to establish the reliability and concurrent validity of gait variability and complexity evaluated with a waist and an ankle-worn IMU. Seventeen women (age 74.8 (SD 44) years) and 10 men (73.7 (4.1) years) attended two laboratory measurement sessions a week apart. Their stride duration variability was concurrently evaluated based on a continuous 3 min walk using a force plate and a waist- and an ankle-worn IMU. Their gait complexity (…
Implant-specific follow-up imaging of treated intracranial aneurysms: TOF-MRA vs. metal artifact reduced intravenous flat panel computed tomography a…
2017
Aim To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. Methods The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n= 20; clipping: n= 15; coiling + stenting: n= 9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-ima…
Auditory cortical and hippocampal local-field potentials to frequency deviant tones in urethane-anesthetized rats: An unexpected role of the sound fr…
2015
Abstract The human brain can automatically detect auditory changes, as indexed by the mismatch negativity of event-related potentials. The mechanisms that underlie this response are poorly understood. We recorded primary auditory cortical and hippocampal (dentate gyrus, CA1) local-field potentials to serial tones in urethane-anesthetized rats. In an oddball condition, a rare (deviant) tone ( p = 0.11) randomly replaced a repeated (standard) tone. The deviant tone was either lower (2200, 2700, 3200, 3700 Hz) or higher (4300, 4800, 5300, 5800 Hz) in frequency than the standard tone (4000 Hz). In an equiprobability control condition, all nine tones were presented at random ( p = 0.11). Diffe…