Search results for "Instrumentation"
showing 10 items of 4914 documents
Particle tracking in kaon electroproduction with cathode-charge sampling in multi-wire proportional chambers
2011
Abstract Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the background rate in the chambers. One way to determine the track of a charged particle through a multi-wire proportional chamber (MWPC) is the measurement of the charge distribution induced on its cathodes. In practical applications of this read-out method, the algorithm to relate the measured charge distribution to the avalanche position is an important factor for the achievable position resolution and for the track reconstruction efficiency. An al…
The PANDA DIRC detectors
2020
Abstract The PANDA experiment at the future Facility for Antiproton and Ion Research (FAIR) will address fundamental questions of hadron physics with unprecedented precision. To reach this goal excellent Particle Identification (PID) is essential over a large range of particle momenta and solid angles. Most of the phase space will be covered by two innovative DIRC (Detection of Internally Reflected Cherenkov light) detectors. The Endcap Disc DIRC and Barrel DIRC will cover the polar angle range from 5 to 22°and 22 to 140°, respectively. Both detectors rely on high precision optical components, lifetime-enhanced Microchannel Plate PMTs (MCP-PMTs), and fast readout electronics.
Planar channeling experiments with electrons at the 855MeV Mainz Microtron MAMI
2008
Abstract Planar channeling has been studied for silicon single crystals at a beam energy of 855 MeV at the Mainz Microtron MAMI. Complex channeling patterns were observed from which the crystal orientation can unambiguously be determined. Photon spectra at (1 0 0), (1 1 0) and (1 1 1) planar channeling were recorded with a 10″ × 10″ NaI detector. The planar (1 1 0) channeling process has been studied as function of the crystal thickness in the range between 7.9 and 270 μm from which a dechanneling length of 18.0 μm and the thickness dependent rechanneling lengths were deduced, employing solutions of the Fokker–Planck equation. A signal derived from high energy bremsstrahlung exhibits a char…
A novel method for obtaining continuous stopping power curves
2001
Abstract A new method has been developed for obtaining continuous stopping power curves in transmission geometry. In the method both the incident energy of the particle and its energy after passing through the sample foil are extracted directly from the semiconductor detector. Full range of energies is measured simultaneously eliminating step-by-step measurements and providing continuous data. A time-of-flight (TOF) spectrometer provides unambiguous matching of relevant particle groups from the run with and without absorber. Suitable energy distribution of incident particles was achieved by choosing the right thickness and tilting angle of a scattering foil. The method is very fast and reli…
The polytron as a cw electron accelerator in the 10 GeV range
1991
Abstract This article is concerned with a generalized microtron, characterized essentially by the number of magnet pairs in its bending system. It is shown that the most serious physical energy limit of the microtron, emittance growth due to synchrotron radiation, may be overcome if this number is raised essentially above what has been considered in the past. The main properties of such “polytrons” are investigated and several design examples for 15 GeV output energy are discussed.
A highly-segmented ΔE-time-of-flight wall as forward detector of the 4π-system for charged particles at the SIS/ESR accelerator
1993
Abstract At the SIS/ESR accelerator facility at GSI in Darmstadt the 4π-detector system FOPI is under construction at present. It is designed for the investigation of central collisions of heavy ions in the energy range up to 2 A GeV. As phase I of this detector a forward wall has been built and used in various experiments. It comprizes a total number of 764 scintillators with an additional shell of 188 thin ΔE -detectors in front of it and covers the full azimuth of the polar angles from 1° to 30°. The velocity and the nuclear charge of the fragments are determined by a combined time-of-flight and ΔE measurement.
FLUXEN portable equipment for direct X-ray spectra measurements
2004
Abstract The proper use of imaging equipment in radiological units is based on an appropriate knowledge of the physical characteristics of the X-ray beam used. The FLUXEN PROJECT is working on a portable apparatus which, together with dedicated software, is able to perform an exact spectral reconstruction of the radiation produced in diagnostic X-ray tubes. The apparatus characterizes the energy spectrum of radiological tubes and also provides a measurement of the emitted flux. The acquisition system is based on a commercial CZT detector (3×3×2 mm 3 ), produced by AMPTEK, cooled by a Peltier cell, with a high efficiency in the diagnostic X-ray energy range and modified in the shaping electr…
Investigation of the elastic and inelastic scattering of He-3 from Be-9 in the energy range 30-60 MeV
2018
We have measured the differential cross-sections for the elastic as well as inelastic scattering populating the 2.43[Formula: see text]MeV [Formula: see text] excited state in [Formula: see text] using [Formula: see text] beams at energies of 30, 40 and 47[Formula: see text]MeV on a [Formula: see text] target. The experimental results for the elastic scattering were analyzed within the framework of the optical model using the Woods–Saxon and double-folding potentials. The theoretical calculations for the concerned excited states were performed using the coupled-channel method. The optimal deformation parameters for the excited states of [Formula: see text] nucleus were extracted.
Rejection Power of A Horizontal Rpc Telescope For Left and Right Coming Cosmic Muons
1993
Abstract The possibility of performing neutrino astronomy by means of a detector above the ground depends critically on the feasibility of a rejection power on the order of 10 11 required to discriminate the enormous background of cosmic downward going muons from the signal of upward going muons produced by neutrinos. In order to check whether and how this rejection is obtainable, we have built in the Physics Department of the University of Bari a horizontal cosmic muon telescope (MINI) instrumented with resistive plate counters. By performing time-of-flight measurements, we have estimated the rejection power of our telescope for left and right coming cosmic muons. The rejection dependence …
A Tracking and Timing (t-and-t) Front-end Electronics For Rpc Detectors
1992
Abstract The availability of a detector such as an RPC (resistive plate counter) opens new possibility on the future experiments for accelerator and non-accelerator physics. The main advantage consists on the possibility to obtain accurate tracking and timing with a low-cost detector and electronics. We report results on time resolution, signal transmission on long strips, efficiency and maintenance. A possible front-end electronics able to give tracking and timing information on each input channel operating in free-running mode will be illustrated toghether to the preliminary tests performed.