Search results for "Instrumentation"
showing 10 items of 4914 documents
Improvement of the LET sensitivity in ESR dosimetry for -photons and thermal neutrons through gadolinium addition
2007
Abstract We investigated the ESR response of new materials, alanine and ammonium tartrate to which gadolinium was added. The addition of gadolinium enhances sensitivity for Co 60 γ -photons because of its high atomic number ( Z = 64 ) and an enhancement of sensitivity for thermal neutrons because of its high thermal neutron cross section and high linear energy transfer (LET) secondary particles produced after the reaction with neutrons. In particular, in this paper we analyzed the microwave power saturation properties of dosimeters of alanine and ammonium tartrate with or without gadolinium exposed to different LET beams. The power saturation trends of dosimeters exposed to photons and to t…
Measurements of neutron radiation and induced radioactivity for the new medical linear accelerator, the Varian TrueBeam
2016
Abstract Contemporary linear accelerators applied in radiotherapy generate X-ray and electron beams with energies up to 20 MeV. Such high-energy therapeutic beams induce undesirable photonuclear (γ,n) and electronuclear (e,e'n) reactions in which neutrons and radioisotopes are produced. The originated neutron can also induce reactions such as simple capture, (n,γ), reactions that produce radioisotopes. In this work measurements of the non-therapeutic neutrons and the induced gamma radiation were carried out in the vicinity of a new medical accelerator, namely the Varian TrueBeam. The TrueBeam is a new generation Varian medical linac making it possible to generate the X-ray beams with a dose…
Spatial distribution of air kerma rate and impact of accelerating voltage on the quality of an ultra soft X-ray beam generated by a cold cathode tube…
2015
Abstract Ultrasoft X-ray characteristic aluminum K alpha line (Al Kα with energy of 1.5 keV) is used in radiobiological experiments to study the effect of radiation on biological matter. A simple method to generate a continuous beam of those X-ray radiations is to bombarding an aluminum target with accelerated electrons using high voltage (HV). In this work, by varying the HV we study the characteristics of a photon beam generated by means of a cold cathode transmission X-ray tube. The anode is a thin (16 μm) aluminum foil supported by a copper grid. The spatial distribution of air kerma is measured using gafchromic films of HD-810 calibrated with a parallel plate free-air ionization chambe…
Single-Dish Radio Polarimetry in the F-GAMMA Program with the Effelsberg 100-m Radio Telescope
2013
Studying the variability of polarized AGN jet emission in the radio band is crucial for understanding the dynamics of moving shocks as well as the structure of the underlying magnetic field. The 100-m Effelsberg Telescope is a high-quality instrument for studying the long-term variability of both total and polarized intensity as well as the electric-vector position angle. Since 2007, the F-GAMMA program has been monitoring the linear polarized emission of roughly 60 blazars at 11 frequencies between 2.7 and 43 GHz. Here, we describe the calibration of the polarimetric data at 5 and 10 GHz and the resulting F-GAMMA full-Stokes light curves for the exemplary case of the radio galaxy 3C 111.
Mapping the Amplitude and Position Response of Double Sided Silicon Strip Detectors with Monocromatic Single Protons
2012
International audience; We are currently developing a novel detection system featuring high angular and energy resolution and able to reconstruct the particles momentum at high precision for different physical cases in multi-fragmentation nuclear physics experiments, based on Double Sided Silicon Strip Detectors as ΔE stages aimed at performing also pulse shape analysis for fragments stopping therein. We carried out a detailed qualification of the performance of the strip detectors. In order to provide the detector response matrix we used a pulsed monoenergetic proton beam. The paper reviews the pulsed proton beam facility of the LaBeC of INFN - Sezione di Firenze and present the results of…
Light Charged Particle Identification by Means of Digital Pulse Shape Acquisition in the CHIMERACsI(Tl) Detectors at GSI Energies
2011
We report the results obtained by applying digital pulse shape acquisition and digital signal processing to the signals from CsI(Tl) scintillators read out by photodiodes at high incident energy (400 MeV/u). The digitized signals allows the discrimination of light charged particles by computing the Fast and Slow components and the Rise Time of the output pulses of the CsI(Tl). When the energies of the light charged particles exceed those corresponding to their ranges in CsI(Tl), the points related to the punching-through particles gather in the corresponding scatter plots giving rise to a cusp. The punching-through points are used as energy calibration points for the reaction products stopp…
Monte Carlo evaluation of a CZT 3D spectrometer suitable for a Hard X- and soft-γ rays polarimetry balloon borne experiment
2015
Today, the measurement of the polarization status of cosmic sources high-energy' emission, is recognized as a key observational parameter to understand the active production mechanism and its geometry. Therefore, a mandatory requirement for new instrumentations operating in this energ.-y range will be to provide high sensitivity for polarimetric measurements. In this framework, we have presented the concept of a small high-performance imaging spectrometer optimized for polarimetry between 100 and 600 keV suitable for a stratospheric balloon-borne payload and as a pathfinder for a future satellite mission. The detector with 3D spatial resolution is based on a CZT spectrometer in a highly seg…
Modeling the energy thermalization of X-ray photons in a microcalorimeter with superconducting absorber
2003
We present a modeling of the response of a microcalorimeter to the absorption of X-ray photons, based on the main microscopical processes responsible for the energy thermalization. In particular, we have modeled a microcalorimeter with superconducting tin absorber (350 micron x 350 micron x 7 micron) and neutron transmutation doped (NTD) germanium thermistor (75 micron x 50 micron x 150 micron). Such a detector, operated at 60 mK, is expected to achieve a spectral resolution as good as 1 eV FWHM in the soft X-ray energy range, based on the known sources of thermal and electronic noise. Nevertheless, the best spectral resolution measured in laboratory experimental tests is of about 5 eV FWHM…
Intense source of slow positrons from pulsed electron accelerators
1984
A pulsed LINAC is used for pair production in a tantalum target of 2.5 radiation lengths in an energy range from 80 to 260 MeV. Several well-annealed tungsten vanes are placed immediately behind the target and thermalize a small fraction of the fast positrons. The slow positrons are extracted from the target region and magnetically guided over a distance of 17 m to the detector at the end of an S-shaped solenoid. Two Nal detectors with well-known detection efficiency are used to register the 511 keV annihilationγ-rays. To reduce pile-up effects 50 mm of Pb were placed in front of the detectors. At an average electron current of 1 μA we could detect about 107 slow positrons per second. The p…
High-voltage monitoring with a solenoid retarding spectrometer at the KATRIN experiment
2014
The KATRIN experiment will measure the absolute mass scale of neutrinos with a sensitivity of m(ν) = 200meV/c(2) by means of an electrostatic spectrometer set close to the tritium β-decay endpoint at 18.6keV. Fluctuations of the energy scale must be under control within ±60mV (±3ppm). Since a precise voltage measurement in the range of tens of kV is on the edge of current technology, a nuclear standard will be deployed additionally. Parallel to the main spectrometer the same retarding potential will be applied to the monitor spectrometer to measure 17.8-keV K-conversion electrons of (83m)Kr. This article describes the setup of the monitor spectrometer and presents its first measurement resu…