Search results for "Instrumentation"

showing 10 items of 4914 documents

Chaos and nonlinearities in high harmonic generation

2016

Linearity is a fundamental postulate of quantum mechanics which is occasionally the subject of debate. This paper investigates the possibility of checking this assumption by using a laser field. We study the corrections caused by the presence of a small nonlinearity in the Hamiltonian of a quantum system. As a model we use a simplified two-level quantum system whose states are coupled by a small off-diagonal term proportional to the population of the upper level. The nonlinearity causes spontaneous decay of the upper level, shift and broadening of the line and the sensitive dependence of the final state on the initial condition. The presence of a strong laser field, resonant with the atomic…

Physicseducation.field_of_studynonlinear Schroedinger equationPhysics and Astronomy (miscellaneous)PopulationLinearity01 natural sciencesharmonic generation; nonlinear Schroedinger equation; Instrumentation; Physics and Astronomy (miscellaneous)harmonic generation010309 opticsNonlinear systemsymbols.namesakeQuantum mechanics0103 physical sciencesQuantum systemsymbolsInitial value problemHigh harmonic generation010306 general physicseducationHamiltonian (quantum mechanics)Nonlinear Schrödinger equationInstrumentation
researchProduct

The optical blocking filter for the ATHENA wide field imager: Ongoing activities towards the conceptual design

2015

ATHENA is the L2 mission selected by ESA to pursue the science theme "Hot and Energetic Universe" (launch scheduled in 2028). One of the key instruments of ATHENA is the Wide Field Imager (WFI) which will provide imaging in the 0.1-15 keV band over a 40'x40' large field of view, together with spectrally and time-resolved photon counting. The WFI camera, based on arrays of DEPFET active pixel sensors, is also sensitive to UV/Vis photons. Optically generated electron-hole pairs may degrade the spectral resolution as well as change the energy scale by introducing a signal offset. For this reason, the use of an X-ray transparent optical blocking filter is needed to allow the observation of all …

PhysicsfilterOffset (computer science)PhotonPixelbusiness.industryElectronic Optical and Magnetic MaterialApplied MathematicsAstrophysics::Instrumentation and Methods for AstrophysicsComputer Science Applications1707 Computer Vision and Pattern RecognitionCondensed Matter PhysicPhoton countingATHENAVibrationInstrumentation for AstrophysicX-rayOpticsConceptual designWFIField-effect transistorSpectral resolutionElectrical and Electronic Engineeringbusiness
researchProduct

Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation II: analysis of in-flight data

2013

After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton we have reviewed the status of its thin and medium filters by performing both analysis of data collected in-flight and laboratory measurements on on-ground back-up filters. We have investigated the status of the EPIC thin and medium filters by performing an analysis of the optical loading in the PN offset maps to gauge variations in the optical and UV transmission of the filters. We both investigated repeated observations of single optically bright targets and performed a statistical analysis of the extent of loading versus visual magnitude at different epochs. We report the results of these …

Physicsgenetic structuresbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaX-Rays: XMM-Newton - X-rays: instrumentation - X-rays: filtersEPICXMM-Newton - X-rays: instrumentation - X-rays: filters [X-Rays]eye diseasesOn boardOpticsApparent magnitudeSettore FIS/05 - Astronomia E AstrofisicaTransmission (telecommunications)ObservatoryData analysisStatistical analysissense organsbusinessFlight data
researchProduct

High-frequency Ramsey excitation in a Penning trap

2007

The Ramsey excitation method for high-precision mass-measurements of highly-charged ions has been investigated and benchmarked using H2+ ions in the Penning-trap mass-spectrometer SMILETRAP. The reason for using H2+ ions are their high cyclotron frequency which is typical for the highly-charged ions usually used at SMILETRAP. Two-, three- and four-pulse Ramsey excitation data are analyzed with the help of recent theoretical work and are compared with the previously used single-pulse excitation data. An improvement factor of 2.9 in the statistical uncertainty is achieved. Furthermore the mass of 76Se, included in the previous Q-value measurement of the 76Ge neutrinoless double beta decay, is…

PhysicslawDouble beta decayCyclotronAtomic physicsMass spectrometryPenning trapInstrumentationMathematical PhysicsExcitationIonlaw.inventionJournal of Instrumentation
researchProduct

Application of optical tomography for measurements of aeration parameters in large water tanks

2003

The paper presents a design and application study of a prototype optical tomograph for the detection and definition of shapes of gas bubbles moving in a liquid. In the applied method of measurements, the column is exposed to a homogeneous light beam and next the ray is detected with the use of optical waveguided detectors. Spatial reconstruction of the bubble shapes is done on the basis of the signals coming from two perpendicular systems of detectors. The bubble shape is approximated by an ellipsoid with suitably determined semi-axes and with the use of genetic algorithms based on the neuron network. Influence of the structure and dynamics of the measuring path on errors in representation …

Physicsmedicine.diagnostic_testBasis (linear algebra)business.industryApplied MathematicsBubbleDetectorEllipsoidOpticsmedicinePerpendicularLight beamTomographyOptical tomographybusinessInstrumentationEngineering (miscellaneous)Measurement Science and Technology
researchProduct

Stray light characterization in a high-resolution imaging spectrometer designed for solar-induced fluorescence

2019

New commercial-off-the-shelf imaging spectrometers promise the combination of high spatial and spectral resolution needed to retrieve solar induced fluorescence (SIF). Imaging at multiple wavelengths for individual plants and even individual leaves from low-altitude airborne or ground-based platforms has applications in agriculture and carbon-cycle science. Data from these instruments could provide insight into the status of the photosynthetic apparatus at scales of space and time not observable with tools based on gas exchange, and could support the calibration and validation activities of current and forthcoming space missions to quantify SIF. High-spectral resolution enables SIF retrieva…

Physicsmedicine.medical_specialtySpectrometerbusiness.industryStray lightOrders of magnitude (temperature)Astrophysics::Instrumentation and Methods for AstrophysicsImaging spectrometerLaserSpectral imagingFraunhofer lineslaw.inventionsymbols.namesakeOpticslawmedicinesymbolsSpectral resolutionbusinessAlgorithms, Technologies, and Applications for Multispectral and Hyperspectral Imagery XXV
researchProduct

Quantifying Changes in Nuclear Organization in Normal vs. Cancer Cells using X-ray Tomography

2014

Physicsmedicine.medical_specialtybusiness.industryNuclear organizationCancer cellX-raymedicineMedical physicsTomographyNuclear medicinebusinessInstrumentationMicroscopy and Microanalysis
researchProduct

Collinear laser spectroscopy at ISOLDE: new methods and highlights

2017

Over three and a half decades of collinear laser spectroscopy and the COLLAPS setup have played a major role in the ISOLDE physics programme. Based on a general experimental principle and diverse approaches towards higher sensitivity, it has provided unique access to basic nuclear properties such as spins, magnetic moments and electric quadrupole moments as well as isotopic variations of nuclear mean square charge radii. While previous methods of outstanding sensitivity were restricted to selected chemical elements with special atomic properties or nuclear decay modes, recent developments have yielded a breakthrough in sensitivity for nuclides in wide mass ranges. These developments include…

Physicsnuclear moments and radiiNuclear and High Energy PhysicsSpinsMagnetic momentIsotope010308 nuclear & particles physics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]7. Clean energy01 natural sciencesNuclear physicsexotic isotopesOrders of magnitude (time)0103 physical sciencesQuadrupolelaser spectroscopyPhysics::Atomic PhysicsNuclide[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Präzisionsexperimente - Abteilung Blaum010306 general physicsSpectroscopyNuclear ExperimentRadioactive decay
researchProduct

Electrical Characterization of CdTe pixel detectors with Al Schottky anode

2014

Abstract Pixelated Schottky Al/p-CdTe/Pt detectors are very attractive devices for high-resolution X-ray spectroscopic imaging, even though they suffer from bias-induced time instability (polarization). In this work, we present the results of the electrical characterization of a (4×4) pixelated Schottky Al/p-CdTe/Pt detector. Current–voltage ( I–V ) characteristics and current transients were investigated at different temperatures. The results show deep levels that play a dominant role in the charge transport mechanism. The conduction mechanism is dominated by the space charge limited current (SCLC) both under forward bias and at high reverse bias. Schottky barrier height of the Al/CdTe con…

PhysicspolarizationNuclear and High Energy PhysicsSchottky contactbusiness.industrySchottky barrierSettore FIS/01 - Fisica SperimentaleSchottky diodeCdTeThermal conductionSpace chargeCadmium telluride photovoltaicsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Settore FIS/03 - Fisica Della MateriaAnodeX-ray and gamma ray spectroscopypixel detectorOptoelectronicsPolarization (electrochemistry)businessCdTe; Schottky contacts; polarization; pixel detectors; X-ray and gamma ray spectroscopyInstrumentationVoltage
researchProduct

Investigation on pixellated CZT detectors coupled with a low power readout ASIC

2008

In this work, we investigated on the spectroscopic performances of two pixellated CZT detectors coupled with a custom low noise and low power readout ASIC. The detectors (10 x 10 x 1 mm3 and 10 x 10 x 2 mm3 single crystals) consist of an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 μm BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) characterized by a dynamic range from 10 keV to 100 keV, low power consumption (0.5 mW/channel) and low noise (150–500 electrons r.m.s.). The spectroscopic results point out the good energy resolution of both detectors at room temperature (5.8 % FWHM at 59.5 keV for the 1 mm thick detec…

PhysicssezelePhysics::Instrumentation and DetectorsDynamic rangebusiness.industryPreamplifierDetectorX-ray detectorTemperature measurementCathodelaw.inventionFull width at half maximumlawOptoelectronicsCharge carrierbusinessCZT detectors
researchProduct