Search results for "Instrumentation"
showing 10 items of 4914 documents
Automatic analysis of speckle photography fringes
1997
Speckle interferometry is a technique adequate to metrological problems such as the measurement of object deformation. An automatic system of analysis of such measurements is given; it consists of a motorized x-y plate positioner controlled by computer, a CCD video camera, and software for image analysis. A fringe-recognition algorithm determines the spacing and orientation of the fringes and permits the calculation of the magnitude and direction of the displacement of the analyzed object point in images with variable degrees of illumination. For a 256 x 256 pixel image resolution, the procedure allows one to analyze from three fringes to a number of fringes that corresponds to 3 pixels/fri…
A low-level spectrometer with a planar low-energy HPGe: shielding arrangement tests and system performance for 210Pb determination in air filter samp…
2001
A system for low-energy photon spectrometry using a planar germanium detector with appropriate specifications is presented. A spectrometric background investigation has been carried out with various detector shielding arrangements. The characteristics of the system for measurements of 210Pb in air-particulate matter on filters have been determined.
TPEN: A Triple-foil differential Plunger for lifetime measurements of excited states in Exotic Nuclei
2019
Abstract A Triple-foil differential Plunger for Exotic Nuclei (TPEN) has been developed to measure the lifetimes of excited states in nuclei with small production cross-sections. TPEN utilises one target foil and two degrader foils to make differential lifetime measurements: directly determining the decay function and its derivative at a single plunger distance setting. The direct measurement of the decay function and its derivative removes the requirement to measure γ -ray intensities at several target-to-degrader distances, thereby reducing the beam-time required relative to a conventional plunger with a single-degrader foil. This paper describes the commissioning of TPEN in the lifetime …
Constraining the neutrino emission of gravitationally lensed Flat-Spectrum Radio Quasars with ANTARES data
2014
This paper proposes to exploit gravitational lensing effects to improve the sensitivity of neutrino telescopes to the intrinsic neutrino emission of distant blazar populations. This strategy is illustrated with a search for cosmic neutrinos in the direction of four distant and gravitationally lensed Flat-Spectrum Radio Quasars. The magnification factor is estimated for each system assuming a singular isothermal profile for the lens. Based on data collected from 2007 to 2012 by the ANTARES neutrino telescope, the strongest constraint is obtained from the lensed quasar B0218+357, providing a limit on the total neutrino luminosity of this source of 1.08×10^46 erg s-1. This limit is about one o…
INTEGRAL/SPI ground calibration
2003
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral resolution and the angular resolution. Absolute determination of the effective area has been obtained from simulations and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on the optical axis, the spectral resolution ~2.3 keV. The angular resolution is better than 2.5 deg and the source separation capability about 1 deg. Some temperature dependant parameters will require permanent in-flight calibration.
The INTEGRAL IBIS/ISGRI System Point Spread Function and Source Location Accuracy
2003
The imager on board INTEGRAL (IBIS) presently provides the most detailed sky images ever obtained at energies above 30 keV. The telescope is based on a coded aperture imaging system which allows to obtain sky images in a large field of view 29deg x 29deg with an angular resolution of 12'. The System Point Spread Function of the telescope and its detailed characteristics are here described along with the specific analysis algorithms used to derive the accurate point-like source locations. The derived location accuracy is studied using the first in-flight calibration data on strong sources for the IBIS/ISGRI system. The dependence of the calibrated location accuracy with the signal to noise r…
Flux and color variations of the quadruply imaged quasar HE 0435-1223
2011
aims: We present VRi photometric observations of the quadruply imaged quasar HE 0435-1223, carried out with the Danish 1.54m telescope at the La Silla Observatory. Our aim was to monitor and study the magnitudes and colors of each lensed component as a function of time. methods: We monitored the object during two seasons (2008 and 2009) in the VRi spectral bands, and reduced the data with two independent techniques: difference imaging and PSF (Point Spread Function) fitting.results: Between these two seasons, our results show an evident decrease in flux by ~0.2-0.4 magnitudes of the four lensed components in the three filters. We also found a significant increase (~0.05-0.015) in their V-R …
Quasi-spherical focal spot in two-photon scanning microscopy by three-ring apodization
2005
International audience; We present a beam-shaping technique for two-photon excitation (TPE) fluorescence microscopy. We show that by inserting a properly designed three-ring pupil filter in the illumination beam of the microscope, the effective optical sectioning capacity of such a system improves so that the point spread function gets a quasi-spherical shape. Such an improvement, which allows the acquisition of 3D images with isotropic quality, is obtained at the expense of only a small increase of the overall energy in the axial sidelobes. The performance of this technique is illustrated with a scanning TPE microscopy experiment in which the image of small beads is obtained. We demonstrat…
Angular spreading measurements using MeV ion microscopes
2013
Abstract The sharpness of MeV ion microscope images is governed by small-angle scattering and associated lateral spreading of the ion beam in the sample. We have investigated measurement of the half-angle of the angular spreading distribution by characterising the image blurring in direct-Scanning Transmission Ion Microscopy (direct-STIM). In these tests Mylar™ foils of 0.5–6 μm were used to induce angular spreading. Images were taken of an electron microscope grid using 2 MeV protons with, and without, the foils in the beam path. The blurring was measured by fitting the width of a circular Gaussian point spread function to the images with and without the foil in position. The results show …
The ATHENA X-ray Integral Field Unit (X-IFU)
2018
Event: SPIE Astronomical Telescopes + Instrumentation, 2018, Austin, Texas, United States.