Search results for "Instrumentation"
showing 10 items of 4914 documents
Evidence for the associated production of a W boson and a top quark in ATLAS at √s = 7 TeV
2012
This Letter presents evidence for the associated production of a W boson and a top quark using 2.05 fb[superscript −1] of pp collision data at √s = 7 TeV accumulated with the ATLAS detector at the LHC. The analysis is based on the selection of the dileptonic final states with events featuring two isolated leptons, electron or muon, with significant transverse missing momentum and at least one jet. An approach based on boosted decision trees has been developed to improve the discrimination of single top-quark Wt events from background. A template fit to the final classifier distributions is performed to determine the cross-section. The result is incompatible with the background-only hypothes…
Precise measurement of the top quark mass in dilepton decays using optimized neutrino weighting
2016
We measure the top quark mass in dilepton final states of top-antitop events in proton-antiproton collisions at sqrt(s) = 1.96 TeV, using data corresponding to an integrated luminosity of 9.7 fb^-1 at the Fermilab Tevatron Collider. The analysis features a comprehensive optimization of the neutrino weighting method to minimize the statistical uncertainties. We also improve the calibration of jet energies using the calibration determined in top-antitop to lepton+jets events, which reduces the otherwise limiting systematic uncertainty from the jet energy scale. The measured top quark mass is mt = 173.32 +/- 1.36(stat) +/- 0.85(syst) GeV.
A self-synchronizing instrument for harmonic sources detection in power systems
2004
The deregulation of energy markets holds out new prospects for contract between customers and utilities, in which the price of energy can depend on voltage quality and load characteristics, as well as on the responsibility for disturbances caused to supply voltage in power systems. In this context, harmonic sources detection is one of the main problems, because of equipment sensibility and the proliferation of loads which absorb non-sinusoidal currents. In this paper the authors present a new instrument based on a time domain method for the detection of harmonic active powers in three-phase systems, which can be usefully applied even in the presence of unbalance or asymmetry. The amplitude …
Metrological characterization and operating principle identification of static meters for reactive energy: an experimental approach under nonsinusoid…
2009
In this paper, an experimental approach is proposed for the metrological characterization of the static meters for reactive energy and for the individuation of their operating principle in nonsinusoidal conditions. The proposed approach was developed by starting from the only available accuracy test condition in the presence of the harmonics introduced by the standards for active static meters. In this paper, the proposed approach is described, and some experimental tests are presented, which were performed on some meters of different accuracy classes and with both known and unknown operating principles.
Comparison of Nonactive Powers for the Detection of Dominant Harmonic Sources in Power Systems
2008
This paper deals with an innovative technique for the detection of disturbing loads in distorted power systems. The technique is a single-point strategy based on a comparison among different ldquononactiverdquo power quantities already proposed in the literature, which are measured at the same metering section. In this paper, the effectiveness of the strategy is discussed, which also considered the errors of the measurement transducers; the analysis is supported by simulation tests, which were carried out on both a simple single-phase system and an IEEE standard three-phase test power system. The latter was used by other authors as a benchmark system for the analysis of multipoint measureme…
Disturbing loads identification in power systems: a single-point time-domain method based on IEEE 1459-2000
2009
This paper presents a single-point method for the identification of prevailing disturbing loads in power systems for both single-phase and three-phase applications downstream or upstream from the metering section. It is based on the simultaneous measurement of three nonactive power quantities, which are based on the IEEE Std. 1459-2000 approach. The proposed method is only based on the separation of the fundamental components from the harmonic content of voltage and current; thus, it does not require any spectral analysis of the voltages and current. In this paper, the formulation of the proposed method and its time-domain implementation are described; moreover, some simulation results are …
Comparison of total-reflection X-ray fluorescence, static and portable energy dispersive X-ray fluorescence spectrometers for art and archeometry stu…
2004
Abstract In this paper, a Total-reflection X-ray Fluorescence (TXRF), a static and a portable Energy Dispersive X-ray Fluorescence (EDXRF) spectrometers are described. Both the equipments and the techniques employed in the field of the art and archeometry are compared. Some applications in this area are presented as well. The aim of the work is to know which spectrometer is the best suited depending on the work of art and the problem treated. The conclusion reached from the experience is that the portable EDXRF spectrometer is advisable to make “in situ” and online analysis in a multidisciplinary environment, the static EDXRF equipment is good to perform analysis on paper and metal pieces a…
Resolution of the photon scanning tunneling microscope: influence of physical parameters
1992
Abstract The photon scanning tunneling microscope (PSTM) is the photon analogue of the electron scanning tunneling microscope (ESTM). It uses the evanescent field due to total internal reflection (TIR) of a light beam in a prism modulated by a sample placed on the base of the prism. Our experimental results shown details which present a lateral size as small as 200 A. The PSTM axial resolution is more difficult to evaluate. It is a function of the roughness of the sample. For very smooth samples, images shown an axial resolution of about 10 A. At last we discuss how both lateral and axial resolution can be affected by several parameters such as the tip surface distance and the roughness of …
An integrated approach of analytical chemistry
1999
The tremendous development of physical methods of analysis offers an impressive number of tools to simultaneously determine a large number of elements and compounds at very low concentration levels. Todays Analytical Chemistry provides appropriate media to solve technical problems and to obtain correct information about chemical systems in order to take the most appropriate decisions for problem solving. In recent years the development of new strategies for sampling, sample treatment and data exploitation through the research on field sampling, microwaveassisted procedures and chemometrics, additionally the revolution of the analytical methodology provided by the development of flow analysi…
The International Measurement Evaluation Programme (IMEP) IMEP-6: "Trace elements in water"
1998
The sixth round of the International Measurement Evaluation Programme (IMEP) is presented. The programme offers reference values, established by primary methods of measurement, against which participating laboratories can evaluate their performance. The degree of comparability is thus established against the most objective references available at present. In IMEP-6, reference values for total concentrations of 14 trace elements in a synthetic and a natural water were established mainly by isotope dilution mass spectrometry (IDMS). For the majority of the measurands, results traceable to the international system of units (SI) and having expanded uncertainties, U (k=2), of 2% could be establi…